Transmission Control ECU and ECM Communication Stop Mode
Circuit diagnosis · Vehicles built Aug 2005 – Oct 2005
Versions by build date: Aug 2005 – Oct 2005 from Nov 2005
DESCRIPTION
| DTC No. |
DTC Detection Conditions |
Trouble Area |
| Transmission Control ECU and ECM Communication Stop Mode |
|
|
- HINT:
- For vehicle with multi-mode manual transaxle only.
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Turn the ignition switch off before measuring the resistances of the CAN main wire and the CAN branch wire.
- After the ignition switch is turned off, check that the key reminder warning system and light reminder warning system are not in operation.
- Before measuring the resistance, leave the vehicle as is for at least 1 minute and do not operate the ignition switch, any other switches or the doors. If doors need to be opened in order to check connectors, open the doors and leave them open.
- HINT:
- Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
- Turn the ignition switch off before measuring the resistances of the CAN main wire and the CAN branch wire.
| 1. CHECK CAN BUS WIRE |
Turn the ignition switch off.

Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
Proceed to
A38-1 (CAN+) - A38-2 (CAN-)
Ignition switch off
54 to 69 Ω
A
A38-1 (CAN+) - A38-2 (CAN-)
Ignition switch off
69 Ω or higher
B
A38-1 (CAN+) - A38-2 (CAN-)
Ignition switch off
54 Ω less
C
|
|
||||
|
|
||||
| A | |
| 2. CHECK CAN BUS LINE FOR SHORT TO +B |
Turn the ignition switch off.

Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - D79-1 (+B)
Ignition switch off
1 MΩ or higher
A38-1 (CAN+) - D79-1 (+B)
Ignition switch off
1 MΩ or higher
|
|
||||
| OK | |
| 3. CHECK CAN BUS LINE FOR SHORT TO GND |
Turn the ignition switch off.

Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - D79-6 (GND)
Ignition switch off
1 kΩ or higher
A38-1 (CAN+) - D79-6 (GND)
Ignition switch off
1 kΩ or higher
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (+B, IG, GND) |
Turn the ignition switch off.

Disconnect the D79 transmission control ECU connector.
Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A79-1 (GND) - Body ground
Always
Below 1 Ω
Measure the voltage.
- Standard voltage:
Tester Connection
Condition
Specified Condition
D79-1 (+B) - Body ground
Always
10 to 14V
D79-3 (IG) - Body ground
Ignition switch on (IG)
10 to 14V
|
|
||||
| NG | |
| 5. CONNECT CONNECTOR |
Reconnect the transmission control ECU connector.
| NEXT | |
| 6. INSPECT ECM POWER SOURCE CIRCUIT |
1KR-FE engine:
Inspect the power source circuit (Click here)
|
|
||||
| NG | ||
| ||
| 7. CHECK CAN BUS LINE FOR SHORT TO +B (TRANSMISSION CONTROL ECU) |
Turn the ignition switch off.

Disconnect the A38 and D79 transmission control ECU connectors.
Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - D79-1 (+B)
Ignition switch off
1 MΩ or higher
A38-2 (CAN-) - D79-1 (+B)
Ignition switch off
1 MΩ or higher
|
|
||||
| NG | |
| 8. CHECK CAN BUS LINE FOR SHORT TO +B (TRANSMISSION CONTROL ECU - ECM) |
1KR-FE engine:

Turn the ignition switch off.
Disconnect the A32 ECM connector.
Measure the resistance.

- HINT:
- The resistance must be measured after the A38 and D79 transmission control ECU connectors are disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - D79-1 (+B)
Ignition switch off
1 MΩ or higher
A38-2 (CAN-) - D79-1 (+B)
Ignition switch off
1 MΩ or higher
2SZ-FE engine:

Turn the ignition switch off.
Disconnect the A21 ECM connector.
Measure the resistance.

- HINT:
- The resistance must be measured after the A38 and D79 transmission control ECU connectors are disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - D79-1 (+B)
Ignition switch off
1 MΩ or higher
A38-2 (CAN-) - D79-1 (+B)
Ignition switch off
1 MΩ or higher
1ND-TV engine:

Turn the ignition switch off.
Disconnect the A49 ECM connector.
Measure the resistance.

- HINT:
- The resistance must be measured after the A38 and D79 transmission control ECU connectors are disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - D79-1 (+B)
Ignition switch off
1 MΩ or higher
A38-2 (CAN-) - D79-1 (+B)
Ignition switch off
1 MΩ or higher
|
|
||||
| NG | ||
| ||
| 9. CHECK CAN BUS LINE FOR SHORT TO GND (TRANSMISSION CONTROL ECU) |
Turn the ignition switch off.

Disconnect the A38 and D79 transmission control ECU connectors.
Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - D79-6 (GND)
Ignition switch off
1 MΩ or higher
A38-2 (CAN-) - D79-6 (GND)
Ignition switch off
1 MΩ or higher
|
|
||||
| NG | |
| 10. CHECK CAN BUS LINE FOR SHORT TO GND (TRANSMISSION CONTROL ECU - ECM) |
1KR-FE engine:

Turn the ignition switch off.
Disconnect the A32 ECM connector.
Measure the resistance.

- HINT:
- The resistance must be measured after the A38 and D79transmission control ECU connectors are disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - D79-6 (GND)
Ignition switch off
1 MΩ or higher
A38-2 (CAN-) - D79-6 (GND)
Ignition switch off
1 MΩ or higher
2SZ-FE engine:

Turn the ignition switch off.
Disconnect the A21 ECM connector.
Measure the resistance.

- HINT:
- The resistance must be measured after the A38 and D79 transmission control ECU connectors are disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - D79-6 (GND)
Ignition switch off
1 MΩ or higher
A38-2 (CAN-) - D79-6 (GND)
Ignition switch off
1 MΩ or higher
1ND-TV engine:

Turn the ignition switch off.
Disconnect the A49 ECM connector.
Measure the resistance.

- HINT:
- The resistance must be measured after the A38 and D79 transmission control ECU connectors are disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - D79-6 (GND)
Ignition switch off
1 MΩ or higher
A38-2 (CAN-) - D79-6 (GND)
Ignition switch off
1 MΩ or higher
|
|
||||
| NG | ||
| ||
| 11. CHECK CAN MAIN WIRE OR CONNECTOR (TRANSMISSION CONTROL ECU) |
Turn the ignition switch off.

Disconnect the A38 transmission control ECU connector.
Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - A38-2 (CAN-)
Ignition switch off
108 to 132 Ω
|
|
||||
| NG | |
| 12. CHECK CAN MAIN WIRE OR CONNECTOR (TRANSMISSION CONTROL ECU - ECM) |
1KR-FE engine:

Turn the ignition switch off.
Disconnect the A32 ECM connector.
Measure the resistance.
- HINT:
- The resistance must be measured after the A38 transmission control ECU connector is disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A32-26 (CAN+) - A38-1 (CAN+)
Always
Below 1 Ω
A32-34 (CAN-) - A38-2 (CAN-)
Always
Below 1 Ω
2SZ-FE engine:

Turn the ignition switch off.
Disconnect the A21 ECM connector.
Measure the resistance.
- HINT:
- The resistance must be measured after the A38 transmission control ECU connector is disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A21-5 (CAN+) - A38-1 (CAN+)
Always
Below 1 Ω
A21-4 (CAN-) - A38-2 (CAN-)
Always
Below 1 Ω
1ND-TV engine:

Turn the ignition switch off.
Disconnect the A49 ECM connector.
Measure the resistance.
- HINT:
- The resistance must be measured after the A38 transmission control ECU connector is disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A49-45 (CAN+) - A38-1 (CAN+)
Always
Below 1 Ω
A49-64 (CAN-) - A38-2 (CAN-)
Always
Below 1 Ω
|
|
||||
| NG | ||
| ||
| 13. CHECK CAN BUS LINES FOR SHORT CIRCUIT (TRANSMISSION CONTROL ECU) |
Turn the ignition switch off.

Disconnect the A38 transmission control ECU connector.
Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - A38-2 (CAN-)
Ignition switch off
108 to 132 Ω
|
|
||||
| NG | |
| 14. CHECK CAN BUS LINES FOR SHORT CIRCUIT (TRANSMISSION CONTROL ECU - ECM) |
1KR-FE engine:

Turn the ignition switch off.
Disconnect the A32 ECM connector.
Measure the resistance.

- HINT:
- The resistance must be measured after the A38 transmission control ECU connector is disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - A38-2 (CAN-)
Ignition switch off
1 MΩ or higher
2SZ-FE engine:

Turn the ignition switch off.
Disconnect the A21 ECM connector.
Measure the resistance.

- HINT:
- The resistance must be measured after the A38 transmission control ECU connector is disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - A38-2 (CAN-)
Ignition switch off
1 MΩ or higher
1ND-TV engine:

Turn the ignition switch off.
Disconnect the A49 ECM connector.
Measure the resistance.

- HINT:
- The resistance must be measured after the A38 transmission control ECU connector is disconnected.
- Standard resistance:
Tester Connection
Condition
Specified Condition
A38-1 (CAN+) - A38-2 (CAN-)
Ignition switch off
1 MΩ or higher
|
|
||||
| NG | ||
| ||