DTC P0443 Evaporative Emission Control System Purge Control Valve Circuit |
| DTC No. | DTC Detection Conditions | Trouble Areas |
| P0443 | Terminal voltage of ECM output circuit does not correspond with drive signals from ECM to EVAP VSV (1 trip detection logic) |
|

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE VSV FOR EVAP CONTROL) |
![]() |
Connect an intelligent tester to the DLC3.
Remove the vacuum hose of the VSV for EVAP from the charcoal canister.
Start the engine and turn the tester on.
Select the following menu items: Powertrain / Engine and ECT / Active Test / Activate the VSV for Evap Control.
When the VSV for EVAP is operated using the intelligent tester, check whether the disconnected hose applies suction to your finger.
| Tester Operation | Specified Conditions |
| VSV is ON | Disconnected hose applies suction to finger |
| VSV is OFF | Disconnected hose applies no suction to finger |
|
| ||||
| NG | |
| 2.INSPECT DUTY VACUUM SWITCHING VALVE (VSV FOR EVAP) |
![]() |
Disconnect the C3 duty vacuum switching valve connector.
Measure the resistance between the terminals of the duty vacuum switching valve.
Reconnect the duty vacuum switching valve connector.
|
| ||||
| OK | |
| 3.INSPECT DUTY VACUUM SWITCHING VALVE (POWER SOURCE VOLTAGE) |
![]() |
Disconnect the C3 duty vacuum switching valve connector.
Turn the ignition switch to ON.
Measure the voltage between the terminal of the wire harness side connector and the body ground.
| Tester Connections | Specified Conditions |
| VSV for EVAP (C3-2) - Body ground | 9 to 14 V |
Reconnect the duty vacuum switching valve connector.
|
| ||||
| NG | |
| 4.CHECK HARNESS AND CONNECTOR (VSV FOR EVAP - INTEGRATION RELAY) |
![]() |
Remove the integration relay from the engine room relay block.
Disconnect the C3 duty vacuum switching valve connector.
Check the resistance.
| Tester Connections | Specified Conditions |
| VSV for EVAP (C3-2) - Engine room relay block (A-4) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| VSV for EVAP (C3-2) or Engine room relay block (A-4) - Body ground | 10 kΩ or higher |
Reinstall the integration relay.
Reconnect the duty vacuum switching valve connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (VSV FOR EVAP - ECM) |
![]() |
Disconnect the C20 ECM connector.
Disconnect the C3 duty vacuum switching valve connector.
Check the resistance.
| Tester Connections | Specified Conditions |
| VSV for EVAP (C3-1) - PRG (C20-49) | Below 1 Ω |
| Tester Connections | Specified Conditions |
| VSV for EVAP (C3-1) or PRG (C20-49) - Body ground | 10 kΩ or higher |
Reconnect the ECM connector.
Reconnect the duty vacuum switching valve connector.
|
| ||||
| OK | ||
| ||