POWER WINDOW CONTROL SYSTEM > INITIALIZATION |
| INITIALIZE POWER WINDOW CONTROL SYSTEM (POWER WINDOW REGULATOR MOTOR ASSEMBLY LH OR RH (DRIVER SIDE)) |
Initialization procedure when replacing the power window regulator motor assembly with a new one:
Connect the battery and turn the ignition switch to ON (at this time, the LED on the power window regulator master switch assembly blinks to indicate that it is ready for initialization).
Fully open the window by fully pushing down the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Fully close the power window by fully pulling up the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position. The LED on the power window regulator master switch assembly stops blinking and illuminates to indicate that the initialization is complete.
Initialization procedure when removing/installing the power window regulator motor assembly:
Connect the battery and turn the ignition switch to ON.
Fully close the power window by fully pulling up the power window regulator master switch assembly, and hold the switch for 6 seconds or more after the window is fully closed (if the power window does not move or stops halfway even when the switch is fully pulled, release the switch and fully pull it again).
Fully open the window by pushing down the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Release the power window regulator master switch assembly. Then fully push down and hold the switch for 4 seconds or more.
Fully close the power window by fully pulling up the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete the initialization.
Initialization procedure when the power window does not fully open:
Connect the battery and turn the ignition switch to ON.
Fully close the power window by fully pulling up the power window regulator master switch assembly, and hold the switch for 6 seconds or more after the window is fully closed (if the power window does not move or stops halfway even when the switch is fully pulled, release the switch and fully pull it again).
Fully open the window by pushing down the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Release the power window regulator master switch assembly. Then fully push down and hold the switch for 4 seconds or more.
Fully close the power window by fully pulling up the power window regulator master switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete the initialization.