DTC B1413 Evaporator Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1413 | An open or short in the No. 1 cooler thermistor (evaporator temperature sensor) circuit. |
|

| 1.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Evaporator Fin Thermistor | Evaporator temperature sensor/ Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F). Short in the circuit: 59.55°C (139.19°F). |
| Result | Proceed to |
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK FOR DTC |
Clear the DTCs (Click here).
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 3.INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) |
Inspect the No. 1 cooler thermistor (evaporator temperature sensor) (Click here).
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY) |
Disconnect the F32 No. 1 cooler thermistor (evaporator temperature sensor) connector.
Disconnect the F41 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| F32-2 - F41-4 (TE) | Always | Below 1 Ω |
| F32-1 - F41-15 (SG-1) | Always | Below 1 Ω |
| F32-2 - Body ground | Always | 10 kΩ or higher |
| F32-1 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||