For a complete wiring diagram, refer to the Wiring Information.
When Monitored:
With the ignition on. Engine RPM greater than 1000 RPM. With no other charging system codes set.
Set Condition:
Battery voltage is one Volt greater than desired voltage for more than 10.0 seconds. Battery voltage greater than 15.75 Volts. One Trip Fault. Three good trips to turn off the MIL.
Possible Causes
(K20) GENERATOR FIELD CONTROL CIRCUIT SHORTED TO VOLTAGE
Using the wiring diagram/schematic as a guide, inspect the wiring and connectors between the Generator and the Powertrain Control Module (PCM).
2.
Look for any chafed, pierced, pinched, or partially broken wires.
3.
Look for broken, bent, pushed out or corroded terminals. Verify that there is good pin to terminal contact in the Generator and Powertrain Control Module connectors.
4.
Perform any Technical Service Bulletins that may apply.