2012 Jeep Wrangler JK Factory Service Manual 28 - DTC-Based Diagnostics

P063A-GENERATOR VOLTAGE SENSE CIRCUIT

P063A-GENERATOR VOLTAGE SENSE CIRCUIT



For a complete wiring diagram, refer to the Wiring Information.


Theory of operation

The Powertrain Control module (PCM) uses the generator field duty cycle signal circuit or F-terminal circuit, to monitor the duty cycle of the Generator. The Generator field duty cycle signal circuit connects to high side of the field windings in the Generator. A Pulse Width Modulated (PWM) high side driver in the voltage regulator turns the field windings ON and OFF. The PCM uses the PWM signal input to determine the Generator load on the engine. This allows the PCM to adjust the idle speed to compensate for high electrical loads. The PCM monitors the status of the Generator field duty cycle signal circuit. When the key is in the RUN position and the engine is OFF, the PCM should detect a duty cycle near 0 percent. However, when the engine is running, the duty cycle should be between 5-95 percent.


Possible Causes

EXCESSIVE RESISTANCE IN THE (A804) GENERATOR SENSE CIRCUIT
(A804) GENERATOR SENSE CIRCUIT SHORTED TO GROUND
GENERATOR
POWERTRAIN CONTROL MODULE (PCM)

Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. (Refer to 28 - DTC-Based Diagnostics/MODULE, Powertrain Control (PCM) - Standard Procedure).


1. DTC IS ACTIVE


1. Start the engine and allow it to reach normal operating temperature.

WARNING:

When the engine is operating, do not stand in direct line with the fan. Do not put your hands near the pulleys, belts or fan. Do not wear loose clothing. Failure to follow these instructions may result in possible serious or fatal injury.

2. With the scan tool, select View DTCs.


Is the status Active for this DTC?

Yes


No


2. (A804) GEN SENSE CIRCUIT SHORTED TO VOLTAGE



1. Turn the ignition off.
2. Disconnect the Generator harness connector.
3. Disconnect the Powertrain Control Module (PCM) C2 harness connector.
4. Turn the ignition on.
5. Measure the voltage of the (A804) Gen Sense circuit in the Generator harness connector.


Is there any voltage present?

Yes


No


3. (A804) GEN SENSE CIRCUIT SHORTED TO GROUND



1. Turn the ignition off.
2. Measure the resistance between ground and the (A804) Gen Sense circuit in the Generator harness connector.


Is the resistance below 1000 Ohms?

Yes


No


4. (A804) GEN SENSE CIRCUIT OPEN OR HIGH RESISTANCE



1. Measure the resistance of the (A804) Gen Sense circuit between the Generator harness connector and the PCM C2 harness connector.


Is the resistance below 5.0 Ohms?

Yes


No


5. GENERATOR


WARNING:

When the engine is operating, do not stand in direct line with the fan. Do not put your hands near the pulleys, belts or fan. Do not wear loose clothing. Failure to follow these instructions may result in possible serious or fatal injury.

1. Connect the Generator harness connector.
2. Connect the Powertrain Control Module (PCM) C2 harness connector.
3. Turn the ignition on.
4. While backprobing, measure the voltage of the (K20) Gen Field Control circuit at the Generator harness connector.
5. Start the engine.
6. With the scan tool, perform the Generator Full Field test.
7. Monitor the voltage of the (K20) Gen Field Control circuit with the Generator Full Field test actuated.


NOTE: The voltage should increase more than 1 Volt.


Does the voltage increase by at least 1 Volt with the Generator Full Field Test on?

Yes


No


6. POWERTRAIN CONTROL MODULE (PCM)


1. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors between the Generator and the Powertrain Control Module (PCM).
2. Look for any chafed, pierced, pinched, or partially broken wires.
3. Look for broken, bent, pushed out or corroded terminals.
4. Perform any Technical Service Bulletins that may apply.


Were any problems found?

Yes


No