RX400h · Service Manual HYBRID SYSTEM

INSPECTION

Inspection


INSPECT REAR CIRCUIT BREAKER SENSOR LH

  1. A112780E01
    Measure the resistance according to the value in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    1(SCR-) - 2(SCR+)
    0.65 to 1.0 kΩ at 20°C (68°F)


INSPECT REAR CIRCUIT BREAKER SENSOR RH

  1. A112781E02
    Measure the resistance according to the value in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    1(SCR-) - 2(SCR+)
    0.65 to 1.0 kΩ at 20°C (68°F)

← REMOVALINSTALLATION →