INSPECTION
Inspection
| INSPECT REAR CIRCUIT BREAKER SENSOR LH |
Measure the resistance according to the value in the table below.

- Standard Resistance:
Tester Connection
Specified Condition
1(SCR-) - 2(SCR+)
0.65 to 1.0 kΩ at 20°C (68°F)
| INSPECT REAR CIRCUIT BREAKER SENSOR RH |
Measure the resistance according to the value in the table below.

- Standard Resistance:
Tester Connection
Specified Condition
1(SCR-) - 2(SCR+)
0.65 to 1.0 kΩ at 20°C (68°F)