2018 / ECLIPSE CROSS / EC - Workshop Manual
23 -AUTOMATIC TRANSMISSION > 23A-CVT > TROUBLESHOOTING<CVT><CVT> > DIAGNOSIS CODE PROCEDURES > CODE NO. P2764 LOCKUP SOLENOID MALFUNCTION
Code No. P2764: Malfunction of Lock-up Solenoid Valve (low input)
DIAGNOSTIC FUNCTION
If a predetermined current does not flow into the lock-up solenoid valve (short to earth), the CVT-ECU will determine the system is defective.
JUDGEMENT CRITERIA
The solenoid valve drive circuit remains short to earth for 0.48 seconds.
PROBABLE CAUSES
- Malfunction of the valve body assembly (Faulty lockup solenoid valve)
- Damaged wiring harness and connectors
- Malfunction of CVT-ECU
DIAGNOSIS PROCEDURE
STEP 1. Check for short to earth in LULS line between the CVT assembly connector and the CVT-ECU connector
Is the check result normal?
Go to Step 2.
Repair the connector(s) or the wiring harness.
STEP 2. Lock-up solenoid valve check
STEP 3. Check for short to earth in power supply line between the CVT assembly connector and the valve body harness connector (lock-up solenoid valve line)
STEP 4. Symptom recheck after erasing diagnosis code