2018 / ECLIPSE CROSS / EC - Workshop Manual
35 -SERVICE BRAKES > 35C-ACTIVE STABILITY CONTROL SYSTEM (ASC) > TROUBLESHOOTING<ASC-ECU><ASC-ECU> > SYMPTOM PROCEDURES > WHEN THE IGNITION SWITCH IS TURNED TO THE "ON" POSITION (ENGINE STOPPED), THE TCL OFF INDICATOR LAMP DOES NOT ILLUMINATE.
Inspection Procedure 4: ABS warning lamp does not illuminate when ignition switch is turned to the ON position (engine stopped).
 
 
caution
  • If there is any problem in the CAN bus lines, an incorrect diagnosis code may be set. Prior to this diagnosis, diagnose the CAN bus lines (Refer to GROUP 54C - CAN Bus Diagnostics Table ).
  • Before replacing the ECU, ensure that the communication circuit is normal.
 
 
OPERATION
  • ASC-ECU sends the illumination request signal of the ABS warning lamp to the combination meter through ETACS-ECU via CAN communication.
  • ASC-ECU illuminates the ABS warning lamp via ETACS-ECU for approximately 3 seconds for valve check with the ignition switch turned to the ON position.
 
 
 
COMMENTS ON TROUBLE SYMPTOM
This may be caused by faults in the CAN bus line, ETACS-ECU, combination meter or ASC-ECU.
 
 
 
PROBABLE CAUSES
  • Damaged wiring harness and connectors
  • Malfunction of ETACS-ECU
  • Combination meter malfunction
  • ASC-ECU malfunction
  • Malfunction of coding data for ETACS-ECU
 
 
 
 
DIAGNOSIS PROCEDURE
STEP 1. M.U.T.-IIISE CAN bus diagnostics
Use M.U.T.-IIISE to diagnose the CAN bus lines.
Is the check result normal?
Go to Step 2.
Repair the CAN bus lines. (Refer to GROUP 54C - CAN Bus Diagnostics Table .)
 
STEP 2. M.U.T.-IIISE diagnosis code
Use M.U.T.-IIISE to check the diagnosis code for the ASC system (Refer to ).
Is the diagnosis code set?
Carry out the diagnosis for the diagnosis code (Refer to ).
Go to Step 3.
 
STEP 3. M.U.T.-IIISE Special Function for other system
Perform the following special function by the combination meter system, and check if the ABS warning lamp illuminates (Refer to GROUP 54A - Combination Meter ).
  • Item 6: Indicator (AUTO)
Is the check result normal?
Go to Step 4.
Replace the combination meter.
 
STEP 4. ETACS-ECU coding data check
Is the check result normal?
Go to Step 6.
Go to Step 5.
 
STEP 5. ETACS-ECU coding data check
Perform the variant coding to the ETACS-ECU.
Is the check result normal?
This diagnosis is complete.
Replace the ETACS-ECU (Refer to GROUP 54A - ETACS-ECU ).
 
STEP 6. M.U.T.-IIISE diagnosis code for other systems
Using M.U.T.-IIISE, check that diagnosis code No. U0141 is not set in the combination meter system.
Is the diagnosis code set?
Diagnose the combination meter (Refer to GROUP 54A - Combination Meter/Troubleshooting ).
Go to Step 7.
 
STEP 7. M.U.T.-IIISE diagnosis code for other systems
Using M.U.T.-IIISE, check that diagnosis code No.U0121 is not set in the ETACS system.
Is the diagnosis code set?
Troubleshoot the ETACS-ECU (Refer to GROUP 54A - ETACS-ECU/Troubleshooting ).
Go to Step 8.
 
STEP 8. Retest the system.
Does the ABS warning lamp turn ON and OFF normally?
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/How to Cope with Intermittent Malfunction ).
Replace the hydraulic unit (integrated with ASC-ECU) (Refer to ).