STEP 3. Right side impact sensor check.
(1) Check that the negative battery terminal is disconnected. If the negative battery terminal is connected, disconnect it.
(2) Alternate the right side impact sensor and left side impact sensor, and then install the alternated sensors.
(3) Connect the negative battery terminal.
(4) After erasing the diagnosis code memory, check the diagnosis code again.
(5) Disconnect the negative battery terminal.
Is the diagnosis code No. B1428 or B1429 set?
Replace the right side impact sensor (Refer to
).
Go to Step 4.