DTC B1502-H
Precautions: Precautions for Diagnosing Trouble · General safety (00)
DTC Detecting Condition and Trouble Area
| DTC detecting condition | Trouble area |
|---|---|
|
B1502-H: Inside Air Temperature Sensor and/or Its Circuit Malfunction Signal voltage of position sensor in inside air temperature sensor is higher than specified value (4.9 V) for specified time continuously. |
•Inside air temperature sensor circuit
•Inside air temperature sensor •HVAC control module |
Circuit Diagram
DTC Confirmation Procedure
1)Start engine and operate A/C system.
DTC Troubleshooting
NOTE:
When DTC B1504-H is indicated together, it is possible that sensor ground circuit is open.
| Step | Action | Yes | No |
|---|---|---|---|
| 1 |
Scan tool parameter check
Is temperature below –40 °C (–40 °F)?
|
Go to Step 2.
|
Intermittent trouble.
|
| 2 |
Inside air temperature sensor signal circuit check
1)Disconnect inside air temperature sensor connector.
2)Connect “A1” and “A2” circuit terminals of inside air temperature sensor connector using service wire.
Is temperature below –40 °C (–40 °F)?
|
Go to Step 3.
|
|
| 3 |
Inside air temperature sensor signal circuit check
1)Connect “A1” and “A2” circuit terminals of “G20” connector using service wire.
Is temperature below –40 °C (–40 °F)?
|
Replace instrument panel harness.
|