DTC C1246/46 Master Cylinder Pressure Sensor Malfunction |

| DTC No. | DTC Detection Condition | Trouble Area |
| C1246/46 | When any of the following conditions is detected: 1. Both of the following conditions continue for at least 30 seconds.
3. Both of the following conditions continue for at least 1.2 seconds.
|
|
| 1.READ VALUE OF INTELLIGENT TESTER (MASTER CYLINDER PRESSURE SENSOR) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position and push the intelligent tester main switch ON.
Select "DATA LIST" mode on the intelligent tester.
| Item | Measurement Item / Range (Display) | Normal Condition | Diagnostic Note |
| MAS CYL PRESS 1 | Master cylinder pressure sensor 1 reading / Min.: 0 V, Max.: 5 V |
| Reading increases when brake pedal is depressed |
Check that the master cylinder pressure value of the master cylinder pressure sensor displayed on the intelligent tester changes when depressing the brake pedal.
| Condition | Proceed to |
| Master cylinder pressure sensor value does not change | A |
| Master cylinder pressure sensor value changes but it is not normal | B |
| Master cylinder pressure sensor value becomes normal | C |
|
| ||||
|
| ||||
| B | |
| 2.CHECK BRAKE PEDAL AND STOP LIGHT SWITCH INSTALLATION |
Check the brake pedal height.
Check the stop light switch installation.
|
| ||||
| OK | |
| 3.INSPECT SKID CONTROL ECU (STP TERMINAL) |
![]() |
Disconnect the skid control ECU connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| S28-7 (STP) - Body ground | Stop light switch ON (Brake pedal depressed) | 8 to 14 V |
| S28-7 (STP) - Body ground | Stop light switch OFF (Brake pedal released | Below 1.5 V |
|
| ||||
| OK | |
| 4.RECONFIRM DTC |
Clear the DTC (Click here).
Check if the same DTC is detected (Click here).
| Condition | Proceed to |
| DTC is output | A |
| DTC is not output | B |
|
| ||||
| A | ||
| ||