1.INSTALL AIR FUEL RATIO SENSOR (for Bank 2 Sensor 1)
Using SST, install the air fuel ratio sensor.
| *a | Fulcrum Length |
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 260 cm (10.2 in.)):
40 N*m (408 kgf*cm, 30 ft.*lbf)
89467B
2.INSTALL AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)
Using SST, install the air fuel ratio sensor.
| *a | Fulcrum Length |
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 260 cm (10.2 in.)):
40 N*m (408 kgf*cm, 30 ft.*lbf)
3.INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY
Install the exhaust manifold sub-assembly (See page Engine / Hybrid System>1GR-FE INTAKE / EXHAUST>EXHAUST MANIFOLD>INSTALLATION).