The speed sensor detects the wheel speed and sends the appropriate signals to the skid control ECU.
The skid control ECU converts these wheel speed signals into a pulse signal and outputs it to the ECM via the combination meter. The ECM determines the vehicle speed based on the frequency of this pulse signal.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0500 | While the vehicle is being driven, no vehicle speed sensor signal is transmitted to the ECM (2 trip detection logic). | ·
Open or short in speed signal circuit ·
Vehicle speed sensor ·
Combination meter assembly ·
ECM ·
Skid control ECU |
The ECM assumes that the vehicle is being driven when the indicated vehicle speed is higher than 9 km/h (5.6 mph). If there is no speed signal from the combination meter despite this condition being met, the ECM interprets this as a malfunction in the speed signal circuit. The ECM then illuminates the MIL and stores the DTC.
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Vehicle Speed.
Drive the vehicle.
Read the value displayed on the intelligent tester.
Vehicle speeds displayed on intelligent tester and speedometer display are equal.
OK
NG
Inspect the circuits that send vehicle speed signals to this system in the meter system (See page Vehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>Speed Signal Circuit).
During inspection for the meter section, if there is an instruction that indicates to go back to inspections for each system, proceed to the next step.
NEXT
Disconnect the ECM connector.
Disconnect the combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F14-28 (+S) - F51-18 (SPD) | Always | Below 1 Ω |
Reconnect the ECM connector.
Reconnect the combination meter assembly connector.
OK
NG
Disconnect the ECM connector.
Disconnect the No. 5 junction block connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5B-2 - F51-18 (SPD) | Always | Below 1 Ω |
Reconnect the ECM connector.
Reconnect the No. 5 junction block connector.
OK
NG