Home › Drivetrain › A750E AUTOMATIC TRANSMISSION / TRANSAXLE › VALVE BODY ASSEMBLY
RM1440E _52 Drivetrain _056133 A750E AUTOMATIC TRANSMISSION / TRANSAXLE _0273927 VALVE BODY ASSEMBLY G

A750E AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35230 1.INSPECT SHIFT SOLENOID VALVE SR

C214329E01
0.057,0.005 0.309,0.207 0.251,0.202 10 *a 1.731,0.218 1.921,0.419 0.191,0.202 10 (-) 2.453,0.218 2.704,0.419 0.251,0.202 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω


Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SR)


b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SR connector

·

Battery negative (-) → Shift solenoid valve SR body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 35210 2.INSPECT SHIFT SOLENOID VALVE SL1 AND SL2

C197715E10
1.76,1 2.208,0.417 false 1.5,1 1.042,0.417 false 1.76,2.99 2.208,2.396 false 1.479,2.969 1.021,2.375 false 0.052,0.01 0.365,0.208 0.313,0.198 10 false *a 2.24,0.198 2.406,0.396 0.167,0.198 10 false 1 0.917,0.198 1.083,0.396 0.167,0.198 10 false 2 2.24,2.188 2.406,2.385 0.167,0.198 10 false 1 0.917,2.188 1.083,2.385 0.167,0.198 10 false 2 1.927,3.927 2.156,4.125 0.229,0.198 10 false (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 false (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω


Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve)


b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 35290 3.INSPECT SHIFT SOLENOID VALVE SLT AND SLU

C209928E28
1.76,0.979 2.208,0.396 false 1.51,0.99 1.052,0.406 false 1.76,2.948 2.208,2.354 false 1.51,2.948 1.052,2.354 false 0.052,0.042 0.365,0.24 0.313,0.198 10 false *a 2.24,0.26 2.406,0.458 0.167,0.198 10 false 1 0.917,0.271 1.083,0.469 0.167,0.198 10 false 2 2.24,2.188 2.406,2.385 0.167,0.198 10 false 1 0.917,2.188 1.083,2.385 0.167,0.198 10 false 2 1.927,3.927 2.125,4.125 0.198,0.198 10 false (-) 1.115,3.927 1.333,4.125 0.219,0.198 10 false (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 -2 20°C (68°F) 5.0 to 5.6 Ω


Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve)


b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
Battery positive (+) with a 21 W bulb → Terminal 2 Battery negative (-) → Terminal 1 Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 35240 4.INSPECT SHIFT SOLENOID VALVE S1

C214327E01
0.056,0.046 0.282,0.191 0.226,0.145 10 *a 2.476,0.25 2.701,0.395 0.226,0.145 10 (+) 3.19,0.25 3.385,0.395 0.194,0.145 10 (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω


Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve S1)


b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S1 connector

·

Battery negative (-) → Shift solenoid valve S1 body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 35250A 5.INSPECT SHIFT SOLENOID VALVE S2

C214328E01
0.057,0.005 0.309,0.207 0.251,0.202 10 *a 1.776,0.188 1.976,0.390 0.200,0.202 10 (-) 2.491,0.188 2.724,0.390 0.233,0.202 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω


Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve S2)


b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S2 connector

·

Battery negative (-) → Shift solenoid valve S2 body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.