Home › Drivetrain › A750F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM
RM1440E _52 Drivetrain _056134 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0273939 AUTOMATIC TRANSMISSION SYSTEM C

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P0748  Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)  


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2 and SR, which are controlled by the ECM. If an open or short circuit occurs in one of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (See page Drivetrain>A750F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).

DTC Code DTC Detection Condition Trouble Area
P0748 The ECM checks for an open or short in the shift solenoid valve SL1 circuit while driving and shifting between 4th and 5th gear (1-trip detection logic).
Output signal duty equals 100%.
HINT:

SL1 output signal duty is less than 100% under normal conditions.


·

Open or short in shift solenoid valve SL1 circuit

·

Shift solenoid valve SL1

·

ECM



MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL1 circuit. The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. Then the ECM performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In case of an open or short circuit, the ECM stops sending current to the circuit.

While driving and shifting between 4th and 5th gears, if the ECM detects an open or short in the shift solenoid valve SL1 circuit, the ECM determines there is a malfunction (See page Drivetrain>A750F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).

WIRING DIAGRAM

C361837E01
0.969,3.083 2.5,3.281 1.531,0.198 10 false Transmission Wire 0.958,2.917 1.417,3.115 0.458,0.198 10 false B32 1.01,1.792 2.677,2.031 1.667,0.24 10 false Shift Solenoid Valve SL1 2.771,1.333 3.083,1.531 0.313,0.198 10 false 12 2.771,2.552 3.083,2.75 0.313,0.198 10 false 4 0.792,2.219 1.104,2.417 0.313,0.198 10 false 2 0.792,1.396 1.104,1.594 0.313,0.198 10 false 1 5.438,1.333 5.75,1.531 0.313,0.198 10 false 33 5.438,2.552 5.75,2.75 0.313,0.198 10 false 32 5.75,2.417 6.208,2.615 0.458,0.198 10 false SL1- 5.75,1.219 6.208,1.417 0.458,0.198 10 false SL1+ 5.917,3.24 6.375,3.438 0.458,0.198 10 false B38 5.917,3.385 6.375,3.583 0.458,0.198 10 false ECM 2.271,1.104 2.729,1.302 0.458,0.198 10 false SL1+ 2.26,2.313 2.719,2.51 0.458,0.198 10 false SL1-

CAUTION / NOTICE / HINT

HINT:

The shift solenoid valve SL1 is turned ON/OFF normally when the shift lever is in D.

ECM gear shift command 1st 2nd 3rd 4th 5th
Shift solenoid valve SL1 OFF OFF OFF OFF ON


PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1)
a.
C214326E02
1.729,1.306 1.53,1.745 false 1.802,1.087 2.057,1.745 false 1.293,1.783 1.656,1.950 0.363,0.167 10 SL1+ 0.055,0.021 0.279,0.187 0.224,0.167 10 *a 1.917,1.783 2.259,1.950 0.343,0.167 10 SL1-

Disconnect the B32 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
12 (SL1+) - 4 (SL1-) 20°C (68°F) 5.0 to 5.6 Ω
12 (SL1+) - Body ground Always 10 kΩ or higher
4 (SL1-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SL1
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
U180915E02
1.979,2.76 2.25,2.219 false 2.563,2.76 2.292,2.219 false 0.052,0.031 0.302,0.229 0.25,0.198 10 false *a 2.24,0.396 2.615,0.625 0.375,0.229 10 false B38 1.458,2.802 2.115,3 0.656,0.198 10 false 33 (SL1+) 2.406,2.802 3.063,3 0.656,0.198 10 false 32 (SL1-)

Disconnect the B38 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B38-33 (SL1+) - B38-32 (SL1-) 20°C (68°F) 5.0 to 5.6 Ω
B38-33 (SL1+) - Body ground Always 10 kΩ or higher
B38-32 (SL1-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Rear view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SL1
a.
C197715E10
1.76,1 2.208,0.417 false 1.5,1 1.042,0.417 false 1.76,2.99 2.208,2.396 false 1.479,2.969 1.021,2.375 false 0.052,0.01 0.365,0.208 0.313,0.198 10 false *a 2.24,0.198 2.406,0.396 0.167,0.198 10 false 1 0.917,0.198 1.083,0.396 0.167,0.198 10 false 2 2.24,2.188 2.406,2.385 0.167,0.198 10 false 1 0.917,2.188 1.083,2.385 0.167,0.198 10 false 2 1.927,3.927 2.156,4.125 0.229,0.198 10 false (+) 1.167,3.927 1.396,4.125 0.229,0.198 10 false (-)

Remove shift solenoid valve SL1.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes operating noise



Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SL1)


OK

NG