This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal +IG when the ignition switch is turned to ON, the indicators will not operate.
Disconnect the F14 meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F14-20 (E1) - Body ground | Always | Below 1 Ω |
| F14-13 (MGND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F14-17 (+IG) - Body ground | Ignition switch ON | 11 to 14 V |
| F14-15 (B) - Body ground | Always | 11 to 14 V |
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
OK
NG