The voltage meter indicates the voltage applied to the +IG terminal of the combination meter.
Operate the intelligent tester according to the display and select the Active Test (See page Vehicle Interior>METER / GAUGE / DISPLAY>METER / GAUGE SYSTEM>DATA LIST / ACTIVE TEST).
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Volt Meter Operation | Voltage meter | 9, 12, 15 or 18 | Perform the test with the vehicle stopped and the engine idling. |
Needle indication is normal.
OK
NG
Disconnect the F14 meter connector.
Measure the resistance and voltage according to the value(s) in the tables below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F14-20 (E1) - Body ground | Always | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| F14-17 (+IG) - Body ground | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V |
| *a | Rear view of wire harness connector
(to Combination Meter Assembly) |
OK
NG