Home › Engine / Hybrid System › 1GR-FE ENGINE CONTROL › SFI SYSTEM

SFI SYSTEM > ECM Power Source Circuit

for Preparation Click here


DESCRIPTION

When the ignition switch is turned to ON, the battery voltage is applied to terminal IGSW of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil of the No. 1 integration relay (EFI MAIN), closing the contacts and supplying power to both terminal +B and +B2 of the ECM.

WIRING DIAGRAM


A227119E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.INSPECT NO. 1 INTEGRATION RELAY (NO. 1 INTEGRATION RELAY - BODY GROUND)


    A223349E01
  1. Remove the No. 1 integration relay from the engine room relay block.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    1E-1 - Body ground
    Always
    11 to 14 V

    Text in Illustration 
    *1
    Engine Room Relay Block
    *a
    Front view of wire harness connector
    (to No. 1 Integration Relay)

  1. Reinstall the No. 1 integration relay.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (NO. 1 INTEGRATION RELAY - BATTERY)
OK


2.INSPECT NO. 1 INTEGRATION RELAY (EFI MAIN)
  1. Inspect the No. 1 integration relay (EFI MAIN) .



NG
REPLACE NO. 1 INTEGRATION RELAY
OK


3.CHECK HARNESS AND CONNECTOR (+B, +B2 AND MREL CIRCUIT)
  1. Check the harness and connectors between the No. 1 integration relay and ECM.

    1. Remove the No. 1 integration relay from the engine room relay block.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open):
      Tester Connection
      Condition
      Specified Condition
      F51-9 (MREL) - 1D-2
      Always
      Below 1 Ω
      F51-22 (+B) - 1D-4
      Always
      F51-23 (+B2) - 1D-4
      Always

      Standard Resistance (Check for Short):
      Tester Connection
      Condition
      Specified Condition
      F51-9 (MREL) or 1D-2 - Body ground
      Always
      10 kΩ or higher
      F51-22 (+B) or 1D-4 - Body ground
      Always
      F51-23 (+B2) or 1D-4 - Body ground
      Always

  1. Check the harness and connectors between the No. 1 integration relay and body ground.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open):
      Tester Connection
      Condition
      Specified Condition
      1D-3 - Body ground
      Always
      Below 1 Ω

  1. Reinstall the No. 1 integration relay.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    B38-12 (E1) - Body ground
    Always
    Below 1 Ω

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.INSPECT ECM (IGSW VOLTAGE)


    A223350E01
  1. Disconnect the ECM connectors.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    F50-21 (IGSW) - B38-12 (E1)
    Ignition switch ON
    11 to 14 V

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to ECM)

  1. Reconnect the ECM connectors.



NG
Go to step 6
OK

REPLACE ECM (Click here)  

6.INSPECT NO. 1 INTEGRATION RELAY (IG2)
  1. Inspect the No. 1 integration relay (IG2) .



NG
REPLACE NO. 1 INTEGRATION RELAY (IG2)
OK


7.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (IG2) - ECM)
  1. Remove the No. 1 integration relay (IG2) from the engine room relay block.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    1C-4 - F50-21 (IGSW)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    1C-4 or F50-21 (IGSW) - Body ground
    Always
    10 kΩ or higher

  1. Reinstall the No. 1 integration relay (IG2).

  1. Reconnect the ECM connector.
    Result 
    Result
    Proceed to
    Out of normal range
    A
    Within normal range (w/ Smart Key System)
    B
    Within normal range (w/o Smart Key System)
    C



B
Go to step 8

C
Go to step 9
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

8.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (IG2) - POWER MANAGEMENT CONTROL ECU)
  1. Remove the No. 1 integration relay (IG2) from the engine room relay block.

  1. Disconnect the power management control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    1C-1 - F81-8 (IG2D)
    Always
    Below 1 Ω
    1C-3 - Body ground
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    F81-8 (IG2D) - Body ground
    Always
    10 kΩ or higher

  1. Reinstall the No. 1 integration relay (IG2).

  1. Reconnect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK SMART KEY SYSTEM 

9.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (IG2) - IGNITION SWITCH ASSEMBLY)
  1. Remove the No. 1 integration relay (IG2) from the engine room relay block.

  1. Disconnect the ignition switch connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    1C-1 - F15-6 (IG2)
    Always
    Below 1 Ω
    1C-3 - Body ground
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    F15-6 (IG2) - Body ground
    Always
    10 kΩ or higher

  1. Reinstall the No. 1 integration relay (IG2).

  1. Reconnect the ignition switch connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


10.INSPECT IGNITION SWITCH
  1. Inspect the ignition switch .



NG
REPLACE IGNITION SWITCH (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION SWITCH ASSEMBLY - BATTERY)