DTC P0606 ECM / PCM Processor |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0606 | Either condition is met:
| ECM |
| Related DTC | P0606: ECM CPU range check |
| Required sensors/Components (Main) | ECM |
| Required sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | Within 1 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever the following DTCs are not present | None |
| Either condition A or B is met | - |
| A. DMA communication | No response |
| B. Watchdog from Monitoring Processor | Not toggle |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.CHECK WHETHER DTC OUTPUT RECURS (P0606) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Clear the DTCs.
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal and wait for 1 minute.
Connect the cable to the negative (-) battery terminal.
Turn the ignition switch to ON.
Enter the following menus: Powertrain / Engine and ECT / Trouble Code.
Read the DTCs.
| Display (DTC Output) | Proceed to |
| P0606 | A |
| No DTC output | B |
|
| ||||
| A | ||
| ||