Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

DTC    B1412/12    Ambient Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The cooler thermistor (ambient temperature sensor) is installed in the front part of the cooler condenser assembly to detect the ambient temperature and control the air conditioning auto mode. The sensor connected to the air conditioning amplifier assembly detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the cooler thermistor (ambient temperature sensor) changes in accordance with the cooler thermistor temperature (ambient temperature). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (ambient temperature sensor) and reads voltage changes as changes in the resistance of the cooler thermistor (ambient temperature sensor).

DTC Code
DTC Detection Condition
Trouble Area
B1412/12
An open or short in the cooler thermistor (ambient temperature sensor) circuit.
  1. Cooler thermistor (ambient temperature sensor)
  2. Harness or connector
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E193111E10


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM (AMBIENT TEMPERATURE SENSOR)
  1. Use the Data List to check if the cooler thermistor (ambient temperature sensor) is functioning properly (Click here).

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sensor
    Cooler thermistor (ambient temperature sensor) /
    Min: -23.3°C (-9.94°F)
    Max: 65.95°C (150.71°F)
    Actual ambient temperature displayed
    Open in the circuit: -23.3°C (-9.94°F).
    Short in the circuit: 65.95°C (150.71°F).

    OK:
    The display is as specified in the normal condition column.

    Result 
    Result
    Proceed to
    OK (When troubleshooting according to problem symptoms table)
    A
    OK (When troubleshooting according to the DTC)
    B
    NG
    C



B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

C
Go to step 2
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)


    E184843E02
  1. Remove the cooler thermistor (ambient temperature sensor) (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    Text in Illustration 
    *a
    Sensing Portion
    *b
    Resistance
    *c
    Allowable Range
    *d
    Temperature

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (refer to the graph).



NG
REPLACE COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR) (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
  1. Disconnect the A23 sensor connector.

  1. Disconnect the F42 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A23-1 - F42-5 (TAM)
    Always
    Below 1 Ω
    A23-2 - F42-13 (SG-2)
    F42-5 (TAM) - Body ground
    Always
    10 kΩ or higher
    F42-13 (SG-2) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)