AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > Blower Motor Circuit |


| 1.PERFORM ACTIVE TEST USING TECHSTREAM (BLOWER WITH FAN MOTOR) |
Select the Active Test, use the Techstream to generate a control command, and then check that the blower with fan motor sub-assembly operates (Click here).
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0, Max.: 31 | - |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR - BATTERY AND BODY GROUND) |
![]() |
Disconnect the F43 motor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| F43-3 (+B) - Body ground | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| F43-1 (GND) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector (to Blower with Fan Motor Sub-assembly) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BLOWER WITH FAN MOTOR AND BODY GROUND) |
Disconnect the F42 amplifier connector.
Disconnect the F43 motor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| F42-23 (BLW) - F43-2 (SI) | Always | Below 1 Ω |
| F42-23 (BLW) - Body ground | Always | 10 kΩ or higher |
| F42-14 (GND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL) |
![]() |
Remove the air conditioning amplifier assembly with its connectors still connected (Click here).
Using an oscilloscope, check the waveform.
| Item | Content |
| Terminal No. (Symbol) | F42-23 (BLW) - F42-14 (GND) |
| Tool Setting | 1 V/DIV., 500 μs/DIV. |
| Condition | Ignition switch ON Blower switch LO |
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
|
| ||||
| OK | |
| 5.REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY |
Replace the blower with fan motor sub-assembly with a new or normally functioning one (Click here).
Operate the blower with fan motor sub-assembly to check that it functions properly.
|
| ||||
| OK | ||
| ||