Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › AIRBAG SYSTEM

DTC    B1830/57    Short in Curtain Shield Squib RH Circuit

DTC    B1831/57    Open in Curtain Shield Squib RH Circuit

DTC    B1832/57    Short to GND in Curtain Shield Squib RH Circuit

DTC    B1833/57    Short to B+ in Curtain Shield Squib RH Circuit

for Preparation Click here


DESCRIPTION

The curtain shield squib RH circuit consists of the center airbag sensor and curtain shield airbag RH.
The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are stored when a malfunction is detected in the curtain shield squib RH circuit.

DTC Code
DTC Detection Condition
Trouble Area
B1830/57
One of the following conditions is met:
  1. The center airbag sensor detects a line short circuit signal 5 times in the curtain shield squib RH circuit during the primary check.
  2. A curtain shield squib RH malfunction.
  3. A center airbag sensor malfunction.
  1. Floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly
B1831/57
One of the following conditions is met:
  1. The center airbag sensor detects an open circuit signal in the curtain shield squib RH circuit for 2 seconds.
  2. A curtain shield squib RH malfunction.
  3. A center airbag sensor malfunction.
  1. Floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly
B1832/57
One of the following conditions is met:
  1. The center airbag sensor detects a short circuit to ground signal in the curtain shield squib RH circuit for 0.5 seconds.
  2. A curtain shield squib RH malfunction.
  3. A center airbag sensor malfunction.
  1. Floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly
B1833/57
One of the following conditions is met:
  1. The center airbag sensor detects a short circuit to B+ signal in the curtain shield squib RH circuit for 0.5 seconds.
  2. A curtain shield squib RH malfunction.
  3. A center airbag sensor malfunction.
  1. Floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly

WIRING DIAGRAM


C174615E19


INSPECTION PROCEDURE

NOTICE:
When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected (Click here).

HINT:
To perform the simulation method, enter check mode (signal check) with the Techstream (Click here), and then wiggle each connector of the airbag system or drive the vehicle on various types of road (Click here).

1.CHECK CURTAIN SHIELD AIRBAG RH (CURTAIN SHIELD SQUIB RH)


    C213949E01
  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Disconnect the connector from the curtain shield airbag RH.

  1. Connect the black wire side of SST (resistance: 2.1 Ω) to connector C.

    CAUTION:
    Never connect the tester to the curtain shield airbag RH (curtain shield squib RH) for measurement, as this may lead to a serious injury due to airbag deployment.

    NOTICE:
    1. Do not forcibly insert SST into the terminals of the connector when connecting SST.
    2. Insert SST straight into the terminals of the connector.

SST
09843-18061  
  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch to ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch off.

  1. Turn the ignition switch to ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1830, B1831, B1832 or B1833 is not output.

    HINT:
    Codes other than DTC B1830, B1831, B1832 and B1833 may be output at this time, but they are not related to this check.

    Text in Illustration 
    *1
    Curtain Shield Squib RH
    *2
    Center Airbag Sensor
    *3
    Connector C
    *4
    SST
    *a
    Front view of wire harness connector
    (to Curtain Shield Squib RH)



NG
Go to step 2
OK

REPLACE CURTAIN SHIELD AIRBAG ASSEMBLY RH (Click here)  

2.CHECK CONNECTOR
  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Disconnect SST from connector C.



    C214775E01
  1. Check that the floor wire connector (on the curtain shield airbag RH side) is not damaged.

    OK:
    The lock button is not disengaged, and the claw of the lock is not deformed or damaged.

    Text in Illustration 
    *1
    Curtain Shield Squib RH
    *2
    Center Airbag Sensor



NG
REPLACE FLOOR WIRE
OK


3.CHECK FLOOR WIRE (CURTAIN SHIELD AIRBAG RH CIRCUIT)


    C213950E01
  1. Disconnect the connectors from the center airbag sensor.

  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    N10-1 (ICR+) - Body ground
    Ignition switch ON
    Below 1 V
    N10-2 (ICR-) - Body ground
    Ignition switch ON
    Below 1 V

  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    N10-1 (ICR+) - N10-2 (ICR-)
    Always
    Below 1 Ω

  1. Release the activation prevention mechanism built into connector B (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    N10-1 (ICR+) - N10-2 (ICR-)
    Always
    1 MΩ or higher
    N10-1 (ICR+) - Body ground
    Always
    1 MΩ or higher
    N10-2 (ICR-) - Body ground
    Always
    1 MΩ or higher

Text in Illustration 
*1
Curtain Shield Squib RH
*2
Floor Wire
*3
Center Airbag Sensor
*4
Connector C
*a
Front view of wire harness connector
(to Curtain Shield Squib RH)


NG
REPLACE FLOOR WIRE
OK


4.CHECK CENTER AIRBAG SENSOR


    C146261E37
  1. Connect the connectors to the curtain shield airbag RH and center airbag sensor.

  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch to ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch off.

  1. Turn the ignition switch to ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1830, B1831, B1832 or B1833 is not output.

    HINT:
    Codes other than DTC B1830, B1831, B1832 and B1833 may be output at this time, but they are not related to this check.

    Text in Illustration 
    *1
    Curtain Shield Squib RH
    *2
    Center Airbag Sensor



NG
REPLACE CENTER AIRBAG SENSOR ASSEMBLY (Click here)
OK

USE SIMULATION METHOD TO CHECK (Click here)