DTC P060B Internal Control Module A/D Processing Performance |
| DTC No. | DTC Detection Condition | Trouble Area |
| P060B | There is an ECM main CPU communication error. | ECM |
| Related DTCs | None |
| Required sensors/Components (Main) | ECM |
| Required sensors/Components (Related) | - |
| Frequency of operation | Continuous |
| Duration | 2 times: AD converter is fail 30 times: Knock sensor circuit is fail, Knock sensor serial communication |
| MIL operation | Immediate |
| Sequence of operation | None |
| Monitor runs whenever following DTCs not present | None |
| One of the following conditions is met | Condition 1, 2 or 3 |
| 1. Internal control module serial communication | Fail |
| 2. AD converter | Fail |
| 3. Knock sensor circuit | Fail |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.CHECK FOR DTC |
Clear the DTCs (Click here).
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal and wait for 1 minute.
Connect the cable to the negative (-) battery terminal.
Turn the ignition switch to ON.
Check for DTCs.
|
| ||||
| OK | ||
| ||