Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM

CAN COMMUNICATION SYSTEM > Yaw Rate Sensor Communication Stop Mode

for Preparation Click here


DESCRIPTION


Detection Item
Symptom
Trouble Area
Yaw Rate Sensor Communication Stop Mode
Either condition is met:
  1. "Yaw Rate / Deceleration Sensor" is not displayed on the "CAN Bus Check" screen.
  2. "Yaw Rate Sensor Communication Stop Mode" in "DTC Combination Table" applies.
  1. Power source or inside yaw rate sensor assembly
  2. Yaw rate sensor assembly branch wire or connector
  3. Yaw rate sensor assembly

WIRING DIAGRAM


C198942E14


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

HINT:
Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.

1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
  1. Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and branch wire.

    CAUTION:
    Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

    NOTICE:
    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).


NEXT


2.CHECK FOR OPEN IN CAN BUS WIRE (YAW RATE SENSOR ASSEMBLY BRANCH WIRE)


    C210013E03
  1. Disconnect the F36 yaw rate sensor assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connector
    Switch Condition
    Specified Condition
    F36-3 (CANH) - F36-2 (CANL)
    Ignition switch off
    54 to 69 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Yaw Rate Sensor Assembly)



NG
REPAIR OR REPLACE YAW RATE SENSOR ASSEMBLY BRANCH WIRE OR CONNECTOR (CANH, CANL)
OK


3.CHECK HARNESS AND CONNECTOR (YAW RATE SENSOR ASSEMBLY - BATTERY AND BODY GROUND)


    C210013E04
  1. Connect the cable to the negative (-) battery terminal.

    NOTICE:
    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    F36-1 (GND) - Body ground
    Always
    Below 1 Ω

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    F36-4 (IG) - Body ground
    Ignition switch ON
    11 to 14 V

Text in Illustration 
*a
Front view of wire harness connector
(to Yaw Rate Sensor Assembly)


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE YAW RATE SENSOR ASSEMBLY (Click here)