Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM

DTC    U0100    Lost Communication with ECM / PCM "A"

for Preparation Click here


DESCRIPTION


DTC Code
DTC Detection Condition
Trouble Area
U0100
There is no communication from the ECM.
  1. Power source or inside ECM
  2. ECM main wire or connector
  3. ECM

HINT:
For vehicles with a smart key system only.


WIRING DIAGRAM


C219181E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

HINT:
Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.

1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
  1. Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and branch wire.

    CAUTION:
    Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

    NOTICE:
    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).


NEXT


2.CHECK FOR OPEN IN CAN BUS MAIN WIRE (ECM MAIN WIRE)


    C215892E04
  1. Disconnect the F50 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    F50-34 (CANP) - F50-33 (CANN)
    Ignition switch off
    108 to 132 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE ECM MAIN WIRE OR CONNECTOR (CANP, CANN)
OK


3.CHECK HARNESS AND CONNECTOR (ECM - BATTERY AND BODY GROUND)


  1. Connect the cable to the negative (-) battery terminal.

    NOTICE:
    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).


    C217328E02


    Text in Illustration 
    *a
    Front view of wire harness connector
    (to ECM)
    -
    -

  1. Disconnect the B38, B39 and F51 ECM connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B38-12 (E1) - Body ground
    Always
    Below 1 Ω
    B39-14 (E01) - Body ground
    Always
    Below 1 Ω
    B39-15 (E02) - Body ground
    Always
    Below 1 Ω
    B39-10 (ME01) - Body ground
    Always
    Below 1 Ω
    F51-12 (EC) - Body ground
    Always
    Below 1 Ω

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    F51-24 (BATT) - Body ground
    Always
    11 to 14 V
    F51-23 (+B2) - Body ground
    Battery positive (+) voltage applied to terminal F51-9 (MREL)
    11 to 14 V
    F51-22 (+B) - Body ground
    Battery positive (+) voltage applied to terminal F51-9 (MREL)
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)