Home › Vehicle Exterior › EXTERIOR PANELS / TRIM › AUTOMATIC RUNNING BOARD SYSTEM

DTC    21    Short to GND in Motor LH Circuit

DTC    23    Short to GND in Motor RH Circuit

for Preparation Click here


DESCRIPTION

When there is a short to GND in the side auto step motor circuit, the side auto step controller ECU assembly does not operate the automatic running board.

DTC No.
Detection Condition
Trouble Area
21
Short to GND in the circuit on the stowing or deploying side of the side auto step motor LH.
  1. Side auto step motor assembly
  2. Side auto step controller ECU assembly
  3. Wire harness or connector
23
Short to GND in the circuit on the stowing or deploying side of the side auto step motor RH.

WIRING DIAGRAM


B297856E01


INSPECTION PROCEDURE

1.INSPECT SIDE AUTO STEP MOTOR ASSEMBLY
  1. Disconnect the O25*1 or N23*2 side auto step motor assembly connector.

    1. *1: for LH
    2. *2: for RH



    B297855E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LH:
    Tester Connection
    Condition
    Specified Condition
    O25-4 (STW1) - Body ground
    Always
    10 kΩ or higher
    O25-4 (STW1) - O25-1 (-1)
    Always
    10 kΩ or higher
    O25-5 (DPL1) - Body ground
    Always
    10 kΩ or higher
    O25-5 (DPL1) - O25-1 (-1)
    Always
    10 kΩ or higher
    for RH:
    Tester Connection
    Condition
    Specified Condition
    N23-4 (STW2) - Body ground
    Always
    10 kΩ or higher
    N23-4 (STW2) - N23-1 (-2)
    Always
    10 kΩ or higher
    N23-5 (DPL2) - Body ground
    Always
    10 kΩ or higher
    N23-5 (DPL2) - N23-1 (-2)
    Always
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Side Auto Step Motor Assembly)
    *A
    for LH
    *B
    for RH



NG
REPLACE SIDE AUTO STEP MOTOR ASSEMBLY (Click here)
OK


2.CHECK HARNESS AND CONNECTOR (SIDE AUTO STEP MOTOR - SIDE AUTO STEP CONTROLLER ECU)
  1. Disconnect the A42 side auto step controller ECU assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LH:
    Tester Connection
    Condition
    Specified Condition
    A42-3 (STW1) - Body ground
    Always
    10 kΩ or higher
    A42-4 (DPL1) - Body ground
    Always
    10 kΩ or higher
    for RH:
    Tester Connection
    Condition
    Specified Condition
    A42-2 (STW2) - Body ground
    Always
    10 kΩ or higher
    A42-1 (DPL1) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE SIDE AUTO STEP CONTROLLER ECU ASSEMBLY (Click here)