DTC C1258 Open Circuit in Transfer 4WD Position Switch Circuit |
DTC C1340 Center Differential Lock Circuit |
| DTC Code | DTC Detection Condition | Trouble Area |
| C1258*1 C1340*2 | An open circuit is detected in the EXI circuit of the skid control ECU. |
|


| 1.CHECK TERMINAL VOLTAGE (EXI) |
Disconnect the A6 skid control ECU connector.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A6-27 (EXI) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Skid Control ECU) |
| Result | Proceed to |
| OK | A |
| NG (for Part-time 4WD) | B |
| NG (for Full-time 4WD) | C |
|
| ||||
|
| ||||
| A | |
| 2.RECONFIRM DTC |
Clear the DTCs (Click here).
Check for DTCs (Click here).
| Result | Proceed to |
| DTC is output | A |
| DTC is not output | B |
|
| ||||
| A | ||
| ||
| 3.CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - FOUR WHEEL DRIVE CONTROL ECU AND A.D.D. ACTUATOR) |
Disconnect the A6 skid control ECU connector.
Disconnect the F47 four wheel drive control ECU connector.
Disconnect the D1 A.D.D. actuator connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A6-27 (EXI) - F47-15 (ADD) | Always | Below 1 Ω |
| A6-27 (EXI) - D1-3 (ADD) | Always | Below 1 Ω |
| A6-27 (EXI) - Body ground | Always | 10 kΩ or higher |
| D1-4 (GND) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| A6-27 (EXI) - F47-14 (ADD) | Always | Below 1 Ω |
| A6-27 (EXI) - D1-3 (ADD) | Always | Below 1 Ω |
| A6-27 (EXI) - Body ground | Always | 10 kΩ or higher |
| D1-4 (GND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - FOUR WHEEL DRIVE CONTROL ECU AND TRANSFER SHIFT ACTUATOR ASSEMBLY) |
Disconnect the A6 skid control ECU connector.
Disconnect the F47 four wheel drive control ECU connector.
Disconnect the B47 transfer shift actuator assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A6-27 (EXI) - F47-14 (P1) | Always | Below 1 Ω |
| A6-27 (EXI) - B47-9 (CDL) | Always | Below 1 Ω |
| A6-27 (EXI) - Body ground | Always | 10 kΩ or higher |
| B47-10 (GND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||