DTC B2274 ACC Monitor Malfunction |
| DTC No. | DTC Detection Condition | Trouble Area | DTC Output Confirmation Operation |
| B2274 | Malfunction in the ACC relay activation circuit in the certification ECU (smart key ECU assembly) or the external circuit (1-trip detection logic*1).
|
| Wait 10 seconds after turning the engine switch on (ACC) or on (IG), and then wait another 10 seconds after turning the engine switch off.
|
| Vehicle Condition when Malfunction Detected | Fail-safe Function when Malfunction Detected |
| - |
| DTC No. | Data List Item | Active Test Item |
| B2274 | Power Source Control
Engine
| - |

| 1.CHECK HARNESS AND CONNECTOR (POWER SOURCE) |
![]() |
Disconnect the D48 certification ECU (smart key ECU assembly) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D48-2 (+B) - Body ground | Always | 9.5 to 16 V |
| *a | Rear view of harness connected (to Certification ECU (Smart Key ECU Assembly)) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (GROUND) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D48-11 (GND) - Body ground | Always | Below 1 Ω |
| *a | Rear view of harness connected (to Certification ECU (Smart Key ECU Assembly)) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - CERTIFICATION ECU) |
Disconnect the D41 certification ECU (smart key ECU assembly) connector.
Disconnect the 3A instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D41-4 (ACCD) - 3A-20 | Always | Below 1 Ω |
| 3A-12 - Body ground | Always | Below 1 Ω |
| D41-4 (ACCD) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (ACC1, ACC2 RELAY) |
Remove the instrument panel junction block assembly (Click here).
Remove the main body ECU (network gateway ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.

| *A | for LHD | *B | for RHD |
| *a | Component without harness connected (Instrument Panel Junction Block Assembly) | - | - |
| Tester Connection | Condition | Specified Condition |
| 3E-1 - 3B-28 | When battery voltage absent | 10 kΩ or higher |
| When battery voltage is applied to terminals 3A-20 and 3A-12 | Below 1 Ω | |
| 3E-1 - 3A-10 | When battery voltage absent | 10 kΩ or higher |
| When battery voltage is applied to terminals 3A-20 and 3A-12 | Below 1 Ω |
|
| ||||
| OK | |
| 5.INSPECT CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) |
![]() |
Install the main body ECU (network gateway ECU) to the instrument panel junction block assembly (Click here).
Install the instrument panel junction block assembly.
Reconnect the D41 certification ECU (smart key ECU assembly) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D41-4 (ACCD) - Body ground | Engine switch off → Engine switch on (ACC) | Below 1 V → 8.5 V or higher |
| *a | Component with harness connected (Certification ECU (Smart Key ECU Assembly)) |
|
| ||||
| OK | ||
| ||