Home › Engine / Hybrid System › FA20 COOLING › THERMOSTAT(for Automatic Transmission)
RM2090E _51 Engine / Hybrid System _060670 FA20 COOLING _0297524 THERMOSTAT(for Automatic Transmission) A

FA20 COOLING  THERMOSTAT(for Automatic Transmission)  INSTALLATION  


PROCEDURE

Hide 16331A 1.INSTALL THERMOSTAT

a.

Install a new gasket to the thermostat.


b.
A280549E02
1.677,0.99 2.469,0.75 true 1.885,0.281 2.167,0.458 0.281,0.177 10 false 10° 1.229,0.281 1.51,0.458 0.281,0.177 10 false 10° 2.531,0.656 2.813,0.833 0.281,0.177 10 false *1

Install the thermostat to the water inlet housing as shown in the illustration.

Text in Illustration
*1 Jiggle Valve
V100135

Upper Side

HINT:

The jiggle valve must be set within 10° on either side of the position shown in the illustration.



Hide 16323 2.CONNECT WATER INLET HOUSING

a.

Install the water inlet housing with the 2 bolts.

Torque:
6.4 N*m (65 kgf*cm, 57 in.*lbf)


Hide 3.CONNECT WATER HOSE

a.

Connect the water hose to the water inlet housing with the hose clamp.