B1011 is stored when a malfunction is detected in the BMPX circuit.
In some cases, none of the functions of the main body ECU (network gateway ECU) may function when B1012 is stored together with B1011.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1011 | When BMPX voltage is 8.3 V or less, or 16.7 V or more (BMPX circuit malfunction) | ·
Main body ECU (network gateway ECU) ·
Instrument panel junction block assembly ·
Harness or connector |
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Clear the DTCs (See page Power Source / Network>POWER DISTRIBUTION>ELECTRIC POWER CONTROL SYSTEM>DTC CHECK / CLEAR).
NEXT
Check for DTCs (See page Power Source / Network>POWER DISTRIBUTION>ELECTRIC POWER CONTROL SYSTEM>DTC CHECK / CLEAR).
| Result | Proceed to |
|---|---|
| DTC B1011 is output | A |
| DTC is not output | B |
A
B
(See pageGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING)
Disconnect the 3C instrument panel junction block assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3C-19 - Body ground | Always | 11 to 14 V |
| *a | Front view of wire harness connector
(to Instrument Panel Junction Block Assembly) |
OK
NG
Disconnect the D6 and A73 main body ECU (network gateway ECU) connector.
Disconnect the 3B instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D6-1 (GND) - Body ground | Always | Below 1 Ω |
| A73-4 (GND) - Body ground | Always | Below 1 Ω |
| 3B-18 - Body ground | Always | Below 1 Ω |
OK
NG
Remove the instrument panel junction block assembly (See page Power Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL).
Remove the main body ECU (network gateway ECU) from the instrument panel junction block assembly.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3C-19 - MB-32 (BMPX) | Always | Below 1 Ω |
| 3B-18 - MB-11 (GND) | Always | Below 1 Ω |
OK
NG