Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)
RM2090E _58 Vehicle Interior _060704 HEATING / AIR CONDITIONING _0297734 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1440/41  Open in Driver Side Air Mix Damper Position Sensor Circuit  B1442/-41  Short in Driver Side Air Mix Damper Position Sensor Circuit  B1446/E41  Driver Side Air Mix Damper Control Servomotor Circuit  


DESCRIPTION

This sensor detects the position of the air mix damper and sends appropriate signals to the A/C amplifier assembly.

The position sensor is built into the air mix control servo motor.

HINT:

Confirm that no mechanical problem is present because this diagnostic code can be output when either a damper link or the damper is mechanically locked.


E109300E01
0.223,0.186 0.962,0.349 0.739,0.163 10 Voltage (V) 0.868,2.91 2.315,3.073 1.448,0.163 10 Damper opening angle 0.773,0.977 0.936,1.147 0.163,0.170 10 4 0.765,1.982 0.914,2.166 0.149,0.184 10 1 0.945,2.472 1.087,2.614 0.142,0.142 10 0 2.251,2.472 2.678,2.614 0.427,0.142 10 100%

DTC No. DTC Detection Condition Trouble Area
B1440/41 Open in driver side air mix damper position sensor circuit
·

No. 5 air conditioning radiator damper servo sub-assembly (air mix (for driver side))

·

Harness or connector between No. 5 air conditioning radiator damper servo sub-assembly (air mix (for driver side)) and air conditioning control assembly.

·

Air conditioning control assembly


B1442/-41 Short in driver side air mix damper position sensor circuit
·

No. 5 air conditioning radiator damper servo sub-assembly (air mix (for driver side))

·

Harness or connector between No. 5 air conditioning radiator damper servo sub-assembly (air mix (for driver side)) and air conditioning control assembly.

·

Air conditioning control assembly


B1446/E41 Driver side air mix damper position sensor circuit
·

Air conditioning radiator damper servo sub-assembly (air mix (for driver side))

·

Harness or connector between air conditioning radiator damper servo sub-assembly (air mix (for driver side)) and air conditioning control assembly.

·

Air conditioning control assembly



WIRING DIAGRAM

E248914E05
4.979,1.792 6.885,2.323 1.906,0.531 10 false No. 5 Air Conditioning Radiator Damper Servo Sub-assembly (Air Mix(for Driver Side)) 2.094,1.042 2.438,1.208 0.344,0.167 10 false TPDr 1.969,0.292 2.448,0.469 0.479,0.177 10 false AMCDr 1.969,0.667 2.448,0.844 0.479,0.177 10 false AMHDr 4.979,1.625 5.25,1.792 0.271,0.167 10 false A24 2.219,1.875 2.448,2.042 0.229,0.167 10 false SG 2.563,1.781 2.656,1.927 0.094,0.146 10 false 6 0.729,2.344 2.854,2.521 2.125,0.177 10 false Air Conditioning Control Assembly 2.229,1.469 2.417,1.635 0.188,0.167 10 false S5 2.531,1.385 2.729,1.552 0.198,0.167 10 false 13 2.531,0.99 2.708,1.135 0.177,0.146 10 false 15 2.531,0.198 2.729,0.344 0.198,0.146 10 false 24 2.531,0.594 2.708,0.75 0.177,0.156 10 false 23 5.156,0.781 5.25,0.927 0.094,0.146 10 false 5 5.146,0.177 5.271,0.344 0.125,0.167 10 false 7 5.146,0.479 5.25,0.635 0.104,0.156 10 false 6 5.156,1.063 5.25,1.208 0.094,0.146 10 false 3 5.156,1.344 5.25,1.49 0.094,0.146 10 false 1 0.729,2.167 1,2.333 0.271,0.167 10 false D20 5.365,0.76 5.563,0.917 0.198,0.156 10 false TP 5.354,0.188 5.781,0.333 0.427,0.146 10 false COOL 5.365,0.479 5.677,0.635 0.313,0.156 10 false HOT 5.365,1.052 5.583,1.198 0.219,0.146 10 false VZ 5.354,1.333 5.667,1.49 0.313,0.156 10 false GND

CAUTION / NOTICE / HINT

NOTICE:

This DTC is stored even for damper link and damper lock, etc. Prior to inspection, confirm that there are no parts with mechanical problems.


PROCEDURE

1.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Operate the driver side temperature adjustment switch.


e.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


f.

Check the value(s) by referring to the table below.


Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Air Mix Damper Position (D)
(A/M Damp Pos-D))
Driver side air mix damper position /
Min.: -32.68%, Max.: 133.33%
MAX COLD: 0%
MAX HOT: 110%
-
Air Mix Damper Target (D)
(A/M Damp Targ-D)
Driver side air mix damper target position /
Min.: -32.68%, Max.: 133.33%
MAX COLD: 0%
MAX HOT: 110%
-

OK:

The display is as specified in the normal condition column.



OK

2.CHECK FOR DTC

NG

3.CHECK HARNESS AND CONNECTOR (NO. 5 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY - AIR CONDITIONING CONTROL ASSEMBLY)
3.CHECK HARNESS AND CONNECTOR (NO. 5 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY - AIR CONDITIONING CONTROL ASSEMBLY)
a.

Disconnect the D20 air conditioning control assembly.


b.

Disconnect the A24 No. 5 air conditioning radiator damper servo sub-assembly (air mix (for driver side)).


c.

Measure the resistance according to the value(s) in the table below.


Standard Resistance:
Tester Connection Condition Specified Condition
A24-1(GND) - D20-6(SG) Always Below 1 Ω
A24-3(VZ) - D20-13 Always Below 1 Ω
A24-5(TP) - D20-15(TPDr) Always Below 1 Ω
A24-6(HOT) - D20-23(AMCDr) Always Below 1 Ω
A24-7(COOL) - D20-24(AMHDr) Always Below 1 Ω
A24-1(GND) - Body ground Always 10 kΩ or higher
A24-3(VZ) - Body ground Always 10 kΩ or higher
A24-5(TP) - Body ground Always 10 kΩ or higher
A24-6(HOT) - Body ground Always 10 kΩ or higher
A24-7(COOL) - Body ground Always 10 kΩ or higher



OK

4.INSPECT NO. 5 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

NG

REPAIR OR REPLACE HARNESS AND CONNECTOR

4.INSPECT NO. 5 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
a.

Remove the No. 5 air conditioning radiator damper servo sub-assembly (air mix (for driver side)) (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT>DISASSEMBLY).


b.

Potentiometer circuit inspection

i.
U190445E01
1.526,0.42 1.821,0.576 0.295,0.156 10 A24 2.605,1.769 2.932,1.907 0.327,0.138 10 GND 2.249,0.711 1.858,1.385 false 2.278,0.632 2.473,0.770 0.195,0.138 10 VZ 2.592,1.843 2.091,1.473 false 0.939,0.416 1.134,0.554 0.195,0.138 10 TP 1.175,0.491 1.549,1.388 false 0.206,0.87 0.619,1.008 0.412,0.138 10 COOL 1.055,1.861 1.429,1.469 false 0.67,1.781 0.981,1.919 0.311,0.138 10 HOT 0.728,0.95 1.309,1.392 false 0.179,0.161 0.490,0.299 0.311,0.138 10 *a

Measure the resistance according to the value(s) in the table below.

Standard resistance
Tester Connection Condition Specified Condition
A24-1(GND) - A24-3(VZ) Always 4.2 to 7.8 kΩ

Text in Illustration
*a Component without harness connected
(No. 5 air conditioning radiator damper servo sub-assembly)


ii.
E249951E01
2.125,0.148 2.286,0.290 0.161,0.142 10 *b 0.448,1.633 0.608,1.775 0.161,0.142 10 *a

Measure the resistance according to the value(s) in the table below.

Standard resistance
Tester Connection Condition Specified Condition
A24-1(GND) - A24-5(TP) MAX. COOL position 3.4 to 6.2 kΩ
A24-1(GND) - A24-5(TP) MAX. HOT position 0.8 to 1.6 kΩ

Text in Illustration
*a MAX. COOL
*b MAX. HOT


iii.
E108925E15
2.291,2.928 3.138,3.100 0.847,0.171 10 Actual Angle 0.2,1.312 0.840,1.477 0.640,0.165 10 3.4 to 6.2 0.2,2.318 0.831,2.492 0.632,0.175 10 0.8 to 1.6 1.043,2.609 1.879,2.783 0.837,0.174 10 MAX. COOL 2.443,2.605 3.161,2.778 0.718,0.173 10 MAX. HOT 0.183,0.536 1.242,0.738 1.059,0.202 10 Resistance (kΩ)

As the arm of the air mix control servo motor moves from the COOL side to the HOT side, the resistance decreases gradually without interruption.



c.

Motor circuit inspection

i.

When the terminal 7(COOL) of the connector A24 is connected to the battery positive terminal, and terminal 6 (HOT) of the connector A24 is connected to the battery negative terminal, confirm that the arm smoothly rotates from HOT to COOL.

HINT:

Because the arm does not automatically stop at servo unit inspection, at inspection, turn off the power supply near COOL.



ii.

When the terminal 7 (HOT) of the connector A28 is connected to the battery positive terminal, and terminal 6 (COOL) of the connector A28 is connected to the battery negative terminal, confirm that the arm smoothly rotates from COOL to HOT.

HINT:

Because the arm does not automatically stop at servo unit inspection, at inspection, turn off the power supply near HOT.





OK

NG

REPLACE NO. 5 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY