The No. 1 cooler thermistor (A/C evaporator temperature sensor) is used to control the operation of the compressor. The No. 1 cooler thermistor has a thermistor that detects the surface temperature of the evaporator. If the temperature is below approximately 3°C (37.4 °F), the ECM turns the compressor OFF. This control is to protect the evaporator by preventing frost from forming on it.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0535 | A/C Evaporator Temperature Sensor Circuit | Voltage output of thermistor below 0.1 V or above 4.85 V for more than 0.5 seconds while air conditioner operated
(1 trip detection logic) |
·
Open or short in No. 1 cooler thermistor circuit ·
No. 1 cooler thermistor ·
ECM |
- | DTC stored |
Read freeze frame data using the intelligent tester or Techstream. Freeze frame data record the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data, from the time the malfunction occurred.
| *a | Rear view of wire harness connector
(to ECM) |
Turn the ignition switch to ON.
Turn the cooler control switch on.
Measure the voltage according to the value(s) in the table below.
| Tester Connections | Condition | Specified Conditions |
|---|---|---|
| E3-14 (ACEV) - E3-31 (E21) | Ignition switch ON | 0.15 to 4.8 V |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (for LHD) | B |
| OK (for RHD) | C |
A
B
C
Disconnect the No. 1 cooler thermistor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connections | Condition | Specified Conditions |
|---|---|---|
| E11-1 - E3-14 (ACEV) | Always | Below 1 Ω |
| E11-2 - E3-31 (E21) | Always | Below 1 Ω |
| Tester Connections | Condition | Specified Conditions |
|---|---|---|
| E11-1 or E3-14 (ACEV) - Body ground | Always | 10 kΩ or higher |
Reconnect the No. 1 cooler thermistor connector.
Reconnect the ECM connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the No. 1 cooler thermistor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>INSPECTION
| Result | Proceed to |
|---|---|
| NG | A |
| OK (for LHD) | B |
| OK (for RHD) | C |
A
B
C