Home › Engine / Hybrid System › 1NR-VE COOLING › COOLING FAN RESISTOR › from 2015.08
RM19Y0E _51 Engine / Hybrid System _042281 1NR-VE COOLING _0196229 COOLING FAN RESISTOR G

1NR-VE COOLING  COOLING FAN RESISTOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT COOLING FAN RESISTOR

a.

Remove the air cleaner inlet assembly.

Click hereEngine / Hybrid System>1NR-VE ENGINE MECHANICAL>ENGINE ASSEMBLY>REMOVAL


b.

Disconnect the cable from the negative battery terminal.



d.
A361117

Disconnect the cooling fan resistor connector.


e.
A198875C09
1.073,1.615 1.458,1.333 true 2.292,1.625 1.958,1.344 true 0.073,0.052 0.25,0.208 0.177,0.156 10 false *a 0.969,1.583 1.125,1.781 0.156,0.198 10 false + 2.375,1.573 2.531,1.771 0.156,0.198 10 false -
*a Component without harness connected
(Cooling Fan Resistor)


Measure the resistance of the cooling fan resistor.

Standard Resistance:
Tester Connection Condition Specified Condition
1(-) - 2(+) 20°C (68°F) 1.17 Ω to 1.43 Ω

If the resistance is not as specified, replace the cooling fan resistor.


f.

Connect the cooling fan resistor connector.



h.

Connect the cable to the negative battery terminal.

Torque:
6.4 N*m (65 kgf*cm, 5 ft.*lbf)


i.

Install the air cleaner inlet assembly.

Click hereEngine / Hybrid System>1NR-VE ENGINE MECHANICAL>ENGINE ASSEMBLY>INSTALLATION