16363
1.INSPECT COOLING FAN MOTOR
Remove the air cleaner inlet assembly.
Click hereEngine / Hybrid System>1NR-VE ENGINE MECHANICAL>ENGINE ASSEMBLY>REMOVAL
| *a | Component without harness connected
(Cooling Fan Motor) |
Check that the motor operates smoothly when battery voltage is applied to the cooling fan motor connector.
Connect the 400 A probe of an ammeter to terminal 2 (+) of the cooling fan motor.
Measure the current while the motor is operating.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (-) - 2 (+) | 20°C (68°F) | 10.0 to 15.0 A |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (-) - 2 (+) | 20°C (68°F) | 6.4 to 9.4 A |
If the result is not as specified, replace the cooling fan motor.
Install the air cleaner inlet assembly.
Click hereEngine / Hybrid System>1NR-VE ENGINE MECHANICAL>ENGINE ASSEMBLY>INSTALLATION