Home › Engine / Hybrid System › 2NR-VE ENGINE CONTROL › SFI SYSTEM(w/ Air Fuel Ratio Sensor) › from 2015.08
RM19Y0E _51 Engine / Hybrid System _042272 2NR-VE ENGINE CONTROL _0196262 SFI SYSTEM(w/ Air Fuel Ratio Sensor) J

2NR-VE ENGINE CONTROL  SFI SYSTEM(w/ Air Fuel Ratio Sensor)  ECM Power Source Circuit  


DESCRIPTION

When the ignition switch is turned to ON, battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MRO terminal of the ECM causes current to flow to the coil of the No. 1 integration relay (EFI-MAIN relay), closing the contacts of the EFI-MAIN relay and supplying power to terminals +B1 and +B2 of the ECM.

WIRING DIAGRAM

A357516E02
5.479,2.188 5.885,2.448 0.406,0.26 10 false A24 5.49,3.177 5.896,3.438 0.406,0.26 10 false A24 5.5,3.656 5.906,3.917 0.406,0.26 10 false A24 5.49,4.135 5.896,4.396 0.406,0.26 10 false A24 5.49,4.656 5.896,4.917 0.406,0.26 10 false C50 5.49,5.104 5.896,5.365 0.406,0.26 10 false C50 5.865,5.104 6.271,5.365 0.406,0.26 10 false E02 5.854,4.646 6.26,4.906 0.406,0.26 10 false E01 5.854,4.135 6.26,4.396 0.406,0.26 10 false MRO 5.854,3.656 6.26,3.917 0.406,0.26 10 false +B2 5.844,3.167 6.25,3.427 0.406,0.26 10 false +B1 5.854,2.188 6.365,2.469 0.51,0.281 10 false IGSW 0.76,5.146 1.365,5.521 0.604,0.375 10 false Battery 0.594,4.354 1.26,4.667 0.667,0.313 10 false FL MAIN 2.344,0.531 2.75,0.792 0.406,0.26 10 false AM 3.125,0.531 3.531,0.792 0.406,0.26 10 false IG1 1.802,1.042 4.083,1.417 2.281,0.375 10 false Ignition or Starter Switch Assembly 1.813,0.875 2.167,1.188 0.354,0.313 10 false E28 0.813,0.781 1.219,1.042 0.406,0.26 10 false AM1 3.938,2.677 4.271,2.917 0.333,0.24 10 false 1F 3.938,2.469 4.271,2.708 0.333,0.24 10 false 18 1.635,2.667 1.969,2.906 0.333,0.24 10 false 1D 1.677,2.469 2.01,2.708 0.333,0.24 10 false 1 4.677,2.344 5.344,2.656 0.667,0.313 10 false ECU IG2 3.938,2.188 4.271,2.427 0.333,0.24 10 false 1D 3.99,1.99 4.323,2.229 0.333,0.24 10 false 5 0.698,2.333 1.333,2.708 0.635,0.375 10 false IG MAIN 1.635,2.188 1.969,2.427 0.333,0.24 10 false 1E 1.688,1.99 2.021,2.229 0.333,0.24 10 false 5 2.771,2.948 3.188,3.229 0.417,0.281 10 false IG2 2.573,4.385 3.292,4.76 0.719,0.375 10 false EFI-MAIN 0.854,3.813 1.323,4.115 0.469,0.302 10 false EFI 2.219,4.802 3.917,5.188 1.698,0.385 10 false No. 1 Integration Relay 6.177,5.865 6.781,6.177 0.604,0.313 10 false ECM 1.635,3.656 1.969,3.896 0.333,0.24 10 false 1F 1.635,3.458 1.969,3.698 0.333,0.24 10 false 17 5.563,2.969 5.896,3.208 0.333,0.24 10 false 1 5.563,3.458 5.896,3.698 0.333,0.24 10 false 2 5.531,3.938 5.865,4.177 0.333,0.24 10 false 28 5.573,4.448 5.906,4.688 0.333,0.24 10 false 4 5.573,4.896 5.906,5.135 0.333,0.24 10 false 5 3.938,4.146 4.271,4.385 0.333,0.24 10 false 1F 3.979,3.938 4.313,4.177 0.333,0.24 10 false 5 3.948,3.656 4.281,3.896 0.333,0.24 10 false 1F 3.938,3.458 4.271,3.698 0.333,0.24 10 false 10 5.51,1.979 5.844,2.219 0.333,0.24 10 false 14 3.438,0.51 3.771,0.75 0.333,0.24 10 false 2 2.167,0.521 2.5,0.76 0.333,0.24 10 false 1

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


PROCEDURE

1.CHECK TERMINAL VOLTAGE (NO. 1 INTEGRATION RELAY)
a.
A360921C01
0.552,0.281 0.969,0.531 0.417,0.25 0.083,0.073 0.448,0.427 0.365,0.354 10 false *a 0.688,0.323 1,0.594 0.313,0.271 10 false 1F
*a Component with harness connected
(No. 1 Integration Relay)


Turn the ignition switch to ON.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
1F-10 - Body ground Ignition switch ON 11 to 14 V



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (EFI-MAIN RELAY) - ECM)

NG

3.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
2.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (EFI-MAIN RELAY) - ECM)
a.

Disconnect the No. 1 integration relay (EFI-MAIN relay) connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1F-10 - A24-1 (+B1) Always Below 1 Ω
1F-10 - A24-2 (+B2) Always Below 1 Ω
1F-10 or A24-1 (+B1) - Body ground Always 10 kΩ or higher
1F-10 or A24-2 (+B2) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
a.

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C50-4 (E01) - Body ground Always Below 1 Ω
C50-5 (E02) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (ECM - NO. 1 INTEGRATION RELAY (EFI-MAIN RELAY))

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (ECM - NO. 1 INTEGRATION RELAY (EFI-MAIN RELAY))
a.

Disconnect the ECM connector.


b.

Disconnect the No. 1 integration relay (EFI-MAIN relay) connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A24-28 (MRO) - 1F-5 Always Below 1 Ω
A24-28 (MRO) or 1F-5 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

5.INSPECT NO. 1 INTEGRATION RELAY (EFI-MAIN RELAY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT NO. 1 INTEGRATION RELAY (EFI-MAIN RELAY)
a.

Inspect the No. 1 integration relay (EFI-MAIN relay).

Click hereEngine / Hybrid System>2NR-VE ENGINE CONTROL>INTEGRATION RELAY>INSPECTION


Result:
Proceed to
OK
NG



OK

6.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (EFI-MAIN RELAY) VOLTAGE)

NG

6.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (EFI-MAIN RELAY) VOLTAGE)
a.
A357519C03
1.5,0.333 1.917,0.583 0.417,0.25 0.094,0.104 0.448,0.406 0.354,0.302 10 false *a 1.635,0.385 2.094,0.698 0.458,0.313 10 false 1F
*a Front view of wire harness connector
(to No. 1 Integration Relay (EFI-MAIN Relay))


Disconnect the No. 1 integration relay (EFI-MAIN relay) connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
1F-17 - Body ground Always 11 to 14 V



Result:
Proceed to
OK
NG



OK

7.CHECK HARNESS AND CONNECTOR (ECM - NO. 1 INTEGRATION RELAY (IG2 RELAY))

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (NO. 1 INTEGRATION RELAY (EFI-MAIN RELAY) - POSITIVE BATTERY TERMINAL)

7.CHECK HARNESS AND CONNECTOR (ECM - NO. 1 INTEGRATION RELAY (IG2 RELAY))
a.

Disconnect the ECM connector.


b.

Disconnect the No. 1 integration relay (IG2 relay) connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A24-14 (IGSW) - 1D-5 Always Below 1 Ω
A24-14 (IGSW) or 1D-5 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

8.INSPECT NO. 1 INTEGRATION RELAY (IG2 RELAY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.INSPECT NO. 1 INTEGRATION RELAY (IG2 RELAY)
a.

Inspect the No. 1 integration relay (IG2 relay).

Click hereEngine / Hybrid System>2NR-VE ENGINE CONTROL>INTEGRATION RELAY>INSPECTION


Result:
Proceed to
OK
NG



OK

9.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (IG2 RELAY) - BODY GROUND)

NG

9.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (IG2 RELAY) - BODY GROUND)
a.

Disconnect the No. 1 integration relay (IG2 relay) connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1D-1 - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

10.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (IG2 RELAY) VOLTAGE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

10.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (IG2 RELAY) VOLTAGE)
a.
A357518C05
1.51,0.323 1.927,0.573 0.417,0.25 0.104,0.115 0.479,0.438 0.375,0.323 10 false *a 1.625,0.365 2,0.688 0.375,0.323 10 false 1E
*a Front view of wire harness connector
(to No. 1 Integration Relay (IG2 Relay))


Disconnect the No. 1 integration relay (IG2 relay) connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
1E-5 - Body ground Always 11 to 14 V



Result:
Proceed to
OK
NG



OK

11.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (IG2 RELAY) - IGNITION OR STARTER SWITCH ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (NO. 1 INTEGRATION RELAY (IG2 RELAY) - POSITIVE BATTERY TERMINAL)

11.CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY (IG2 RELAY) - IGNITION OR STARTER SWITCH ASSEMBLY)
a.

Disconnect the No. 1 integration relay (IG2 relay) connector.


b.

Disconnect the ignition or starter switch assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1F-18 - E28-2 (IG1) Always Below 1 Ω
1F-18 or E28-2 (IG1) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

12.INSPECT IGNITION OR STARTER SWITCH ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

12.INSPECT IGNITION OR STARTER SWITCH ASSEMBLY
a.

Inspect the ignition or starter switch assembly.

Click hereEngine / Hybrid System>2NR-VE STARTING>IGNITION SWITCH>INSPECTION


Result:
Proceed to
OK
NG



OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION OR STARTER SWITCH ASSEMBLY - POSITIVE BATTERY TERMINAL)

NG

REPLACE IGNITION OR STARTER SWITCH ASSEMBLY