HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  HV Battery High-voltage Line Circuit  


DESCRIPTION

The cause of the malfunction may be the HV battery high-voltage line circuit.

Check the continuity in the high-voltage line from the HV battery to the inverter.

Check the connection condition and for an open circuit in the frame wire from the service plug grip, EV electric battery fuse and HV battery to the inverter and perform a function check of the system main relay.

Related Parts Check
Area Inspection Step
High-voltage circuit from HV battery to inverter Check connection condition and for open circuit. 1, 5, 6
Service plug grip Check connection condition and for open circuit. 2, 3
EV electric battery fuse Check for open circuit. 4
System Main Relay Check operation condition as relay. 7, 8

SYSTEM DESCRIPTION

The HV battery high voltage is supplied to the inverter via the system main relay operation.

WIRING DIAGRAM

A378791E10
6.896,4.729 7.052,4.927 0.156,0.198 10 false * 6.906,5.156 7.063,5.354 0.156,0.198 10 false * 6.917,5.635 7.073,5.833 0.156,0.198 10 false * 6.208,4.729 6.635,4.917 0.427,0.188 10 false SMRB 6.198,5.188 6.698,5.417 0.5,0.229 10 false SMRG 6.219,5.646 6.646,5.833 0.427,0.188 10 false SMRP 3.906,1.292 4.333,1.479 0.427,0.188 10 false SMRB 3.854,4.24 4.344,4.438 0.49,0.198 10 false SMRG 3.865,5.646 4.292,5.833 0.427,0.188 10 false SMRP 3.969,6.115 4.396,6.302 0.427,0.188 10 false GND 2.823,5.979 3.25,6.167 0.427,0.188 10 false SMRP 2.813,4.552 3.292,4.75 0.479,0.198 10 false SMRG 2.802,1.615 3.323,1.823 0.521,0.208 10 false SMRB 0.26,3.396 1.052,3.667 0.792,0.271 10 false HV Battery 0.073,1.458 0.948,1.823 0.875,0.365 10 false Service Plug Grip 1.271,7.375 2.99,7.656 1.719,0.281 10 false : HV Battery Voltage Line 3.073,7.375 4.781,7.646 1.708,0.271 10 false *: with Monitor Circuit 0.063,2.375 1.042,2.823 0.979,0.448 10 false Hybrid Battery Terminal Block 1.552,0.917 1.719,1.083 0.167,0.167 10 false A 1.49,3.875 1.75,4.042 0.26,0.167 10 false z10 1.573,0.75 1.75,0.958 0.177,0.208 10 false 1 1.844,0.802 2.01,0.969 0.167,0.167 10 false + 1.833,3.75 2,3.917 0.167,0.167 10 false - 1.573,3.708 1.76,3.938 0.188,0.229 10 false 1 1.156,2.135 1.417,2.302 0.26,0.167 10 false z11 1.188,2.833 1.448,3 0.26,0.167 10 false z7 1,2.167 1.167,2.333 0.167,0.167 10 false 1 1.01,2.865 1.177,3.031 0.167,0.167 10 false 1 1.875,6.698 4.552,7.052 2.677,0.354 10 false HV Battery Junction Block Assembly 5.333,6.813 7.094,7.135 1.76,0.323 10 false Hybrid Vehicle Control ECU 5.708,2.458 7.094,2.854 1.385,0.396 10 false Inverter with Converter Assembly 5.719,2.302 5.979,2.51 0.26,0.208 10 false T1 6.302,0.948 6.635,1.104 0.333,0.156 10 false CBI 6.302,1.802 6.635,1.958 0.333,0.156 10 false CEI 6.125,0.802 6.302,1.01 0.177,0.208 10 false 1 6.125,1.667 6.333,1.865 0.208,0.198 10 false 2 4.031,0.833 4.365,0.99 0.333,0.156 10 false CBI 4.417,0.927 4.677,1.135 0.26,0.208 10 false T3 4.417,3.875 4.677,4.083 0.26,0.208 10 false T2 4.458,0.771 4.656,0.969 0.198,0.198 10 false 1 4.458,3.698 4.646,3.885 0.188,0.188 10 false 1 4.042,3.75 4.375,3.906 0.333,0.156 10 false CEI 4.354,6.188 4.781,6.375 0.427,0.188 10 false M42 4.354,5.729 4.781,5.917 0.427,0.188 10 false M42 4.365,4.313 4.792,4.5 0.427,0.188 10 false M42 4.354,1.365 4.781,1.552 0.427,0.188 10 false M42 4.458,1.208 4.656,1.427 0.198,0.219 10 false 1 4.458,5.552 4.635,5.76 0.177,0.208 10 false 2 4.458,4.135 4.646,4.313 0.188,0.177 10 false 4 4.458,6.01 4.635,6.208 0.177,0.198 10 false 3 5.354,6.635 5.615,6.844 0.26,0.208 10 false F2 6.063,4.729 6.26,4.948 0.198,0.219 10 false 4 6.063,5.656 6.26,5.875 0.198,0.219 10 false 3 6.063,5.198 6.26,5.396 0.198,0.198 10 false 1

CAUTION / NOTICE / HINT

This step is referenced from the procedures for each DTC.

If the inspection results below are normal, perform the next procedure for the referenced DTC.

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery



·
A371653

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.


·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.


·
A371654C01
1.563,1.229 1.333,0.813 true 1.156,0.677 1.469,0.875 0.313,0.198 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK INVERTER WITH CONVERTER ASSEMBLY (HV FLOOR UNDER WIRE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A376137

Check that the bolts for the HV floor under wire is tightened to the specified torque, the HV floor under wire is connected securely, and there are no contact problems.

Specified Condition:

T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)



c.

Disconnect the HV floor under wire from the inverter with converter assembly.


d.

Check for arc marks at the terminals for the HV floor under wire.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



e.

Reconnect the HV floor under wire.



A

2.CHECK SERVICE PLUG GRIP (CONNECTION CONDITION)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

2.CHECK SERVICE PLUG GRIP (CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


a.

Visually check the connection of the service plug grip to the HV battery. Remove the service plug grip and check for contamination.

OK:

Dirt or foreign matter has not entered the connectors, and there is no evidence of contamination.



b.

Install the service plug grip.


Result:
Proceed to
OK
NG



OK

3.INSPECT SERVICE PLUG GRIP

NG

3.INSPECT SERVICE PLUG GRIP
CAUTION:

Be sure to wear insulated gloves.



b.
A365294C03
0.104,0.083 0.417,0.24 0.313,0.156 10 false *1
*1 Service Plug Grip


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Service plug grip terminals Always Below 1 Ω



c.

Install the service plug grip.


Result:
Proceed to
OK
NG



OK

4.CHECK HYBRID BATTERY TERMINAL BLOCK

NG

4.CHECK HYBRID BATTERY TERMINAL BLOCK
CAUTION:

Be sure to wear insulated gloves and protective goggles.


a.

Remove the Hybrid battery terminal block.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>FUSE BOX>REMOVAL


b.
A367707C04
0.104,0.083 0.417,0.24 0.313,0.156 10 false *1
*1 Hybrid Battery Terminal Block


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Hybrid battery terminal block Always Below 1 Ω



c.

Install the Hybrid battery terminal block.


Result:
Proceed to
OK
NG



OK

5.CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (HV FLOOR UNDER WIRE)

NG

REPLACE HYBRID BATTERY TERMINAL BLOCK

5.CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (HV FLOOR UNDER WIRE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 HV battery cover panel RH.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL


c.
A376114

Check the HV floor under wire is connected securely, and there are no contact problems.


d.

Disconnect the HV floor under wire connectors from the HV battery junction block assembly.


e.

Check for arc marks on the terminals of the HV floor wire and the HV battery junction block assembly.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



f.

Connect the HV floor under wire connectors to the HV battery junction block assembly.


g.

Install the No. 1 HV battery cover panel RH.



A

6.CHECK HV FLOOR UNDER WIRE

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

6.CHECK HV FLOOR UNDER WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the No. 1 HV battery cover panel RH.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL


c.
A376114

Disconnect the HV floor under wire connectors from the HV battery junction block assembly.


d.
A376129

Disconnect the HV floor under wire connector from the inverter with converter assembly.


e.

Measure the resistance according to the value(s) in the table below.

A378816C07
1.875,0.802 2.188,1.021 0.313,0.219 3.802,0.521 4.115,0.74 0.313,0.219 5.677,0.521 5.99,0.74 0.313,0.219 6.26,2.438 6.615,2.438 false 4.396,0.698 4.073,1.094 false 5.333,0.708 5.708,1.115 false 1.906,1.635 1.26,2.042 false 2.229,1.635 2.771,2.042 false 1.25,1.24 1.604,1.24 false 6.667,2.375 6.979,2.531 0.313,0.156 10 false *1 0.865,0.583 1.177,0.74 0.313,0.156 10 false *a 3.708,0.167 4.021,0.323 0.313,0.156 10 false *b 1.948,0.833 2.26,0.99 0.313,0.156 10 false T1 3.875,0.552 4.188,0.708 0.313,0.156 10 false T3 5.76,0.552 6.073,0.708 0.313,0.156 10 false T2 3.813,1.042 4.125,1.198 0.313,0.156 10 false CBI 5.76,1.073 6.073,1.229 0.313,0.156 10 false CEI 0.979,1.99 1.292,2.146 0.313,0.156 10 false CBI 2.875,1.979 3.188,2.135 0.313,0.156 10 false CEI 1.063,1.188 1.375,1.344 0.313,0.156 10 false *1
*1 Shield Ground - -
*a HV Floor Under Wire
(Inverter with Converter Assembly Side)
*b HV Floor Under Wire
(HV Battery Junction Block Assembly Side)


Standard Resistance:
Tester Connection Condition Specified Condition
T1-1 (CBI) - T3-1 (CBI) Power switch off Below 1 Ω
T1-2 (CEI) - T2-1 (CEI) Power switch off Below 1 Ω


NOTICE:

Be sure not to damage or deform the terminal being inspected.



f.

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
T1-1 (CBI) or T3-1(CBI) - Body ground and shield ground Power switch off 10 MΩ or higher
T1-2 (CEI) or T2-1(CEI) - Body ground and shield ground Power switch off 10 MΩ or higher
T1-1 (CBI) - T1-2 (CEI) Power switch off 10 MΩ or higher
T3-1 (CBI) - T2-1 (CEI) Power switch off 10 MΩ or higher



g.

Reconnect the HV floor under wire connector to the inverter with converter assembly.


h.

Reconnect the HV floor under wire connectors to the HV battery junction block assembly.


i.

Install the No. 1 HV battery cover panel RH.


Result:
Proceed to
OK
NG



OK

7.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)

NG

7.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRB)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the HV battery junction block assembly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL


c.

Measure the resistance according to the value(s) in the table below.

A378136C64
3.844,1.073 4.208,1.281 0.365,0.208 3.167,0.208 3.552,0.427 0.385,0.219 5.635,0.177 5.979,0.396 0.344,0.219 3.385,1.188 3.094,1.354 true 3.604,1.188 3.844,1.375 true 3.771,0.396 3.406,0.667 true 5.813,0.708 6.313,1.125 true 0.104,0.094 0.417,0.25 0.313,0.156 10 false *a 3.708,1.385 4.167,1.563 0.458,0.177 10 true SMRB 2.927,1.385 3.281,1.573 0.354,0.188 10 true GND 3.854,0.302 4.167,0.469 0.313,0.167 10 true CBI 3.896,1.094 4.208,1.25 0.313,0.156 10 false M42 3.281,0.24 3.521,0.396 0.24,0.156 10 true T3 6.396,1.115 6.573,1.313 0.177,0.198 10 true + 5.708,0.198 5.927,0.375 0.219,0.177 10 true A
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
A-1 (+) - T3-1 (CBI) Auxiliary battery voltage not applied between terminals M42-1 (SMRB) and M42-3 (GND) 10 kΩ or higher
A-1 (+) - T3-1 (CBI) Auxiliary battery voltage applied between terminals M42-1 (SMRB) and M42-3 (GND) Below 1 Ω



d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M42-1 (SMRB) - M42-3 (GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω



e.

Install the HV battery junction block assembly.


Result:
Proceed to
OK
NG



OK

8.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRG)

NG

REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY

8.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRG)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the HV battery junction block assembly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL


c.

Measure the resistance according to the value(s) in the table below.

A378136C65
3.844,1 4.208,1.208 0.365,0.208 1.156,0.167 1.521,0.375 0.365,0.208 2.24,0.177 2.604,0.385 0.365,0.208 3.385,1.188 3.573,1.375 true 3.271,1.177 3.063,1.365 true 1.323,0.656 0.74,0.958 true 2.063,0.542 2.385,0.656 true 0.104,0.094 0.417,0.25 0.313,0.156 10 false *a 3.896,1.021 4.208,1.177 0.313,0.156 10 false M42 3.469,1.396 3.781,1.563 0.313,0.167 10 true GND 2.854,1.396 3.302,1.573 0.448,0.177 10 true SMRG 0.615,0.969 0.781,1.115 0.167,0.146 10 true - 1.229,0.177 1.51,0.344 0.281,0.167 10 true z10 2.354,0.198 2.594,0.344 0.24,0.146 10 true T2 1.76,0.458 2.031,0.625 0.271,0.167 10 true CEI
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z10-1 (-) - T2-1 (CEI) Auxiliary battery voltage not applied between terminals M42-4 (SMRG) and M42-3 (GND) 10 kΩ or higher
z10-1 (-) - T2-1 (CEI) Auxiliary battery voltage applied between terminals M42-4 (SMRG) and M42-3 (GND) Below 1 Ω



d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M42-4 (SMRG) - M42-3 (GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω



e.

Install the HV battery junction block assembly.


Result:
Proceed to
OK
NG



OK

HV BATTERY HIGH-VOLTAGE LINE CIRCUIT NORMAL (PERFORM NEXT STEP FOR REFERENCED DTC)

NG

REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY