Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2018.05–2019.09
RM32K0E _51 Engine / Hybrid System _059620 HYBRID / BATTERY CONTROL _0292486 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0ABF2A  Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range  


DESCRIPTION

Refer to the description for DTC P0ABF11.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0ABF11

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0ABF2A Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range The battery current sensor output is stuck even when battery voltage change.
(1 trip detection logic)
·

Battery voltage sensor

·

HV battery junction block assembly


Comes on Master Warning:
Comes on

Related Data List
DTC No. Data List
P0ABF2A Hybrid Battery Current for Hybrid Battery Control *1

HINT:

*1: The value of "Hybrid Battery Current for Hybrid Battery Control" usually changes by 4 A or more while the vehicle is accelerating and decelerating.


CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Drive the vehicle on urban roads for approximately 5 minutes.

7.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check and record any HV system DTCs and freeze frame data.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
Only DTC P0ABF2A is output or DTC P0ABF2A and DTCs other than those in the following table are output. A
DTC P0ABF2A and any of the DTCs in the following table are output at the same time. B


Relevant DTC
P0A9563 High Voltage Fuse Accumulated Load History
P0ABF11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground
P0ABF15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open
P0AFC00 Hybrid/EV Battery Sensor Module
P0AFC96 Hybrid/EV Battery Sensor Module Component Internal Failure
P1CBB12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery
P1CBB14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open
P308A12 Hybrid/EV Battery Voltage Sensor All Circuit Short to Auxiliary Battery
P0B3B14, P0B4014, P0B4514, P0B4A14, P0B4F14, P0B5414, P0B5914, P0B5E14, P0B6314, P0B6814 Hybrid/EV Battery Voltage Sensor "A - J" Circuit Short to Ground or Open


e.

Turn the power switch off.



A

2.READ VALUE USING GTS

B

2.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).

NOTICE:

Do not turn the power switch on (READY).



c.

Enter the following menus: Powertrain / Hybrid Control / Data List / Hybrid Battery Block 1 to 9 Voltage.

NOTICE:

Select "Hybrid Battery Block 1 to 9 Voltage" only. (Do not select any other Data List items.)


Powertrain > Hybrid Control > Data List
Tester Display
Hybrid Battery Block 1 Voltage
Hybrid Battery Block 2 Voltage
Hybrid Battery Block 3 Voltage
Hybrid Battery Block 4 Voltage
Hybrid Battery Block 5 Voltage
Hybrid Battery Block 6 Voltage
Hybrid Battery Block 7 Voltage
Hybrid Battery Block 8 Voltage
Hybrid Battery Block 9 Voltage
50003 397 161,162,163,164,165,166,167,168,169

d.

Check the voltage of each "Battery Block Vol" of "Hybrid Battery Block 1 to 9 Voltage" in the Data List with the power switch on (IG).

A315508E23
0.052,2.26 5.375,2.531 5.323,0.271 10 false Example: The change in voltage of "Hybrid Battery Block 2 Voltage" is 0.3 V or more. 0.052,0.031 5.313,0.438 5.26,0.406 10 false Example: The change in voltage of "Hybrid Battery Block 1 Voltage" is less than 0.3 V. 0.135,1.24 1.219,1.583 1.083,0.344 10 false Less than 0.3 V 6.75,3.313 7.156,3.531 0.406,0.219 10 false 0.3 V 6.75,1.24 7.156,1.458 0.406,0.219 10 false 0.3 V 0.969,3.302 1.969,3.563 1,0.26 10 false 0.3 V or more 3.833,4.188 4.833,4.448 1,0.26 10 false 60 seconds 0.052,4.469 5.563,4.781 5.51,0.313 10 false NOTICE: Check the voltage of each "Battery Block Vol" in the same manner.

Specified Condition:

Any "Battery Block Vol" changes by 0.3 V or more, 60 seconds after the power switch is turned on (IG). (The difference between the maximum and minimum voltage is 0.3 V or more.)


Result:
Result Proceed to
The change in voltage of any "Hybrid Battery Block Voltage" is 0.3 V or more. A
Other than above B



e.

Turn the power switch off.



A

B

REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY