A battery current sensor is installed to the positive (+) terminal side of the HV battery and detects current flowing from the HV battery. The battery current sensor outputs voltage, which changes between 0 and 5 V according to the detected amperage, to the IB terminal of the battery voltage sensor. The battery voltage sensor sends signals to the hybrid vehicle control ECU. The hybrid vehicle control ECU determines the charging and discharging amount of the HV battery based on the received signals and calculates the SOC of the HV battery through the accumulated amperage.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground | The battery current sensor output voltage is excessively low.
(1 trip detection logic) |
·
Battery voltage sensor ·
HV battery junction block assembly ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open | The battery current sensor output voltage is excessively high.
(1 trip detection logic) |
·
Battery voltage sensor ·
HV battery junction block assembly ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery | Power source voltage of the battery current sensor is excessively high.
(1 trip detection logic) |
·
Battery voltage sensor ·
HV battery junction block assembly ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open | Power source voltage of the battery current sensor is excessively low.
(1 trip detection logic) |
·
Battery voltage sensor ·
HV battery junction block assembly ·
Wire harness or connector |
Comes on | Master Warning:
Comes on |
| DTC No. | Data List |
|---|---|
| P0ABF11 | Hybrid Battery Current *1 |
| P0ABF15 | |
| P1CBB12 | |
| P1CBB14 |
*1: The value of "Hybrid Battery Current *1" will be approximately 0 A when the power switch is on (IG) (READY off).
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
With power switch on (IG) and wait for 10 seconds or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for DTC P0AFC00.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0AFC00, P0AFC96 or P308A12 is not output. | A |
| P0AFC00, P0AFC96 or P308A12 is also output. | B |
Turn the power switch off.
A
B
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery cover panel RH.
Disconnect the battery current sensor connector from the HV battery junction block assembly.
Before disconnecting the connector, check that it is not loose or disconnected.
Remove the No. 1 hybrid battery exhaust duct.
Disconnect the battery voltage sensor connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Rear view of wire harness connector
(to Battery Voltage Sensor) |
| *b | Front view of wire harness connector
(to HV Battery Junction Block Assembly (Battery Current Sensor)) |
Measure the resistance according to the value(s) in the tables below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z12-5 (IB0) - z13-4 (IB0) | Power switch off | Below 1 Ω |
| z12-12 (GIB) - z13-3 (GIB) | Power switch off | Below 1 Ω |
| z12-6 (VIB) - z13-1 (VIB) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z12-5 (IB0) or z13-4 (IB0) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| z12-12 (GIB) or z13-3 (GIB) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| z12-6 (VIB) or z13-1 (VIB) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
As the battery harness is not available as a supply part, if the harness cannot be repaired, replace the HV battery.
Reconnect the battery voltage sensor connector.
Install the No. 1 hybrid battery exhaust duct.
Reconnect the battery current sensor connector to the HV battery junction block assembly.
Install the No. 1 HV battery cover panel RH.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery exhaust duct.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected
(Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z12-6 (VIB) - z12-12 (GIB) | Power switch on (IG) | 4.6 to 5.4 V |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery exhaust duct.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery exhaust duct.
Disconnect the battery voltage sensor connector.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Component without harness connected
(Battery Voltage Sensor) |
Measure the resistance according to the value(s) in the tables below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z12-12 (GIB) - M41-5 (GND) | Power switch off | Below 1 Ω |
Reconnect the battery voltage sensor connector.
Install the No. 1 hybrid battery exhaust duct.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery exhaust duct.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected
(Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z12-5 (IB0) - z12-12 (GIB) | Power switch on (IG) | 2.46 to 2.54 V |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery exhaust duct.
| Result | Proceed to |
|---|---|
| OK | A |
| NG(Voltage is outside the specified value and 0.4 V or more.) | B |
| NG(Voltage is outside the specified value and less than 0.4 V.) | C |
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery exhaust duct.
Disconnect the battery voltage sensor connectors.
Before disconnecting the connector, check that it is not loose or disconnected.
| *a | Component without harness connected
(Battery Voltage Sensor) |
Measure the resistance according to the value(s) in the tables below.
| Tester Connection | Condition |
|---|---|
| z12-6 (VIB) - z12-5 (IB0) | Power switch off |
| Result | Proceed to |
|---|---|
| Below 1 Ω | A |
| Other than above | B |
Reconnect the battery voltage sensor connectors.
Install the No. 1 hybrid battery exhaust duct.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery cover panel RH.
Disconnect the battery current sensor connector from the HV battery junction block assembly.
Before disconnecting the connector, check that it is not loose or disconnected.
Remove the No. 1 hybrid battery exhaust duct.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected
(Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z12-5 (IB0) - z12-12 (GIB) | Power switch on (IG) | 4.6 to 5.4 V |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery exhaust duct.
Reconnect the battery current sensor connector to the HV battery junction block assembly.
Install the No. 1 HV battery cover panel RH.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery cover panel RH.
Disconnect the battery current sensor connector from the HV battery junction block assembly.
Before disconnecting the connector, check that it is not loose or disconnected.
Remove the No. 1 hybrid battery exhaust duct.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected
(Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z12-6(VIB) - z12-12 (GIB) | Power switch on (IG) | 4.6 to 5.4 V |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery exhaust duct.
Reconnect the battery current sensor connector to the HV battery junction block assembly.
Install the No. 1 HV battery cover panel RH.
| Proceed to |
|---|
| OK |
| NG |
OK
NG