Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404406 HYBRID CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY) C

2ZR-FXE HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY)  P1C8149  High Voltage Power Resource Circuit Consumption Circuit Short  P1C8249  High Voltage Power Resource Circuit Over Loading  


DTC SUMMARY

MALFUNCTION DESCRIPTION


The hybrid vehicle control ECU monitors the high-voltage wiring between the HV battery and inverter with converter assembly and detects a short circuit malfunction or high-voltage system operation malfunction.

The cause of this malfunction may be one of the following:

Battery current sensor (IB) circuit malfunction
·

Battery current sensor (IB) malfunction

·

Motor generator control ECU (MG ECU) malfunction

·

Communication (wire harness) malfunction


High voltage system malfunction
·

HV battery malfunction

·

HV battery junction block assembly malfunction

·

Inverter with converter assembly malfunction

·

Air conditioner system malfunction

·

High-voltage wire harness malfunction

·

High-voltage connector or connection malfunction


Low-voltage circuit (12 V) malfunction
·

Hybrid vehicle control ECU malfunction

·

Low voltage wire harness malfunction

·

Low voltage connector malfunction



INSPECTION DESCRIPTION


A380119E03
1.115,3.333 1.938,3.552 0.823,0.219 10 false HV Battery 0.979,1.5 2.167,1.719 1.188,0.219 10 false Service Plug Grip 1.813,4.458 4.146,4.688 2.333,0.229 10 false HV Battery Junction Block Assembly 4.604,3.813 6.938,4.042 2.333,0.229 10 false Inverter with Converter Assembly 5.052,1.323 7.156,1.542 2.104,0.219 10 false Compressor with Motor Assembly 4.958,3.219 6.031,3.427 1.073,0.208 10 false Boost Converter 6.271,3.229 6.823,3.438 0.552,0.208 10 false Inverter 2.854,2.365 3.885,2.771 1.031,0.406 10 false Battery Current Sensor 2.313,2.344 2.781,2.552 0.469,0.208 10 false SMRB 2.323,3.219 2.792,3.427 0.469,0.208 10 false SMRG 2.323,3.781 2.792,3.99 0.469,0.208 10 false SMRP 2.865,3.771 3.802,4.167 0.938,0.396 10 false System Main Resistor 1.167,4.75 2.51,5.01 1.344,0.26 10 false : High Voltage Line 1.167,5.073 2.51,5.333 1.344,0.26 10 false : Inspection Areas 4.531,0.656 4.75,0.875 0.219,0.219 10 false *a 4.167,1.969 4.385,2.188 0.219,0.219 10 false *b

System Diagram Location Inspection Content Reason Inspection Step
*a Check high-voltage wiring connection condition of the air conditioner compressor with motor assembly Check for short circuit 2, 4
*b Check the high voltage cables between the HV battery junction block assembly and inverter with converter assembly. Check for short circuit 3, 5


DESCRIPTION

Refer to the description for DTC P0AE411.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>P0AE411

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P1C8149 High Voltage Power Resource Circuit Consumption Circuit Short High-voltage circuit malfunctions between the HV battery and inverter with converter assembly.
Excessive overcurrent equal to a short occurs during precharge (time from when SMRP turns on until SMRG turns on).
(1 trip detection logic)
·

Air conditioning wire

·

Compressor with motor assembly

·

Inverter with converter assembly

·

HV battery junction block assembly

·

HV floor under wire


Does not come on Master Warning:
Comes on
P1C8249 High Voltage Power Resource Circuit Over Loading High-voltage circuit malfunctions between the HV battery and inverter with converter assembly.
Small battery overcurrent occurs during precharge (time from when SMRP turns on until SMRG turns on) and current continues to flow after precharge.
(1 trip detection logic)
·

Air conditioning wire

·

Compressor with motor assembly

·

Inverter with converter assembly

·

HV battery junction block assembly

·

HV floor under wire


Does not come on Master Warning:
Comes on

Related Data List
DTC No. Data List
P1C8149
·

Hybrid Battery Voltage

·

Hybrid Battery Current

·

VL-Voltage before Boosting

·

VH-Voltage after Boosting


P1C8249

CONFIRMATION DRIVING PATTERN

HINT:

After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (READY) and wait for 30 seconds or more.

6.

Turn the power switch off and wait for 30 seconds or more.

7.

Turn the power switch on (IG) and turn the GTS on.

8.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

9.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A394823

If this DTC is output, do not turn the power switch on (READY) until the repair has been completed. This DTC means an excessive amperage flow through the system main resistor. The system main resistor may overheat and be damaged if the power switch is turned on (READY) repeatedly before repair.


·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery



·
A371653

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.


·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.


·
A371654C01
1.563,1.229 1.333,0.813 true 1.156,0.677 1.469,0.875 0.313,0.198 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL, MOTOR GENERATOR)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Result:
Result Proceed to
P1C8149 or P1C8249 only is output, or DTCs except the ones in the tables below are also output. A
DTCs of hybrid control system in the tables below are output. B
DTCs of motor generator control system in the tables below are output. C


Malfunction Content System Relevant DTC
Microcomputer malfunction Hybrid control system P060647 Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure
P0AFC96 Hybrid/EV Battery Sensor Module Component Internal Failure
P0AFC00 Hybrid/EV Battery Sensor Module
Power source circuit malfunction Hybrid control system P0AFC16 Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold
Communication system malfunction Hybrid control system U029A87 Lost Communication with Hybrid/EV Battery Sensor Module Missing Message
Sensor and actuator circuit malfunction Hybrid control system P0ABF11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground
P0ABF15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open
P0B3B14 Hybrid/EV Battery Voltage Sensor "A" Circuit Short to Ground or Open
P0B4014 Hybrid/EV Battery Voltage Sensor "B" Circuit Short to Ground or Open
P0B4514 Hybrid/EV Battery Voltage Sensor "C" Circuit Short to Ground or Open
P0B4A14 Hybrid/EV Battery Voltage Sensor "D" Circuit Short to Ground or Open
P0B4F14 Hybrid/EV Battery Voltage Sensor "E" Circuit Short to Ground or Open
P0B5414 Hybrid/EV Battery Voltage Sensor "F" Circuit Short to Ground or Open
P0B5914 Hybrid/EV Battery Voltage Sensor "G" Circuit Short to Ground or Open
P0B5E14 Hybrid/EV Battery Voltage Sensor "H" Circuit Short to Ground or Open
P0B6314 Hybrid/EV Battery Voltage Sensor "I" Circuit Short to Ground or Open
P0B6814 Hybrid/EV Battery Voltage Sensor "J" Circuit Short to Ground or Open
P308A13 Hybrid/EV Battery Voltage Sensor All Circuit Open
P0AFC62 Hybrid/EV Battery Sensor Module Signal Compare Failure
P0B231C Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range
P308A12 Hybrid/EV Battery Voltage Sensor All Circuit Short to Auxiliary Battery
P0ABF00 Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance
P0ABF28 Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure
P0ABF2A Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range
Motor generator control system P0A1114 DC/DC Converter Enable Circuit Short to Ground or Open
P0A1112 DC/DC Converter Enable Circuit Short to Battery
P1CCC96 DC/DC Converter Enable Component Internal Failure
System malfunction Motor generator control system P0D3319 DC/DC Converter Circuit Current Above Threshold

HINT:

P1C8149 or P1C8249 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





e.

Turn the power switch off.



A

2.CHECK COMPRESSOR WITH MOTOR ASSEMBLY

B

C

2.CHECK COMPRESSOR WITH MOTOR ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A376122

Disconnect the air conditioning wire connector from the inverter with converter assembly.


c.
A380308C06
0.5,0.583 0.813,0.781 0.313,0.198 1.427,0.688 0.667,1.24 true 1.677,0.688 2.406,1.323 true 2.729,0.563 2.49,0.906 2.49,0.906 3.01,0.656 true 0.063,0.063 0.375,0.219 0.313,0.156 10 false *a 2.354,0.906 2.667,1.063 0.313,0.156 10 true *b 0.563,0.594 0.875,0.75 0.313,0.156 10 false U2 0.51,1.281 0.927,1.469 0.417,0.188 10 false ACPE 2.292,1.354 2.708,1.542 0.417,0.188 10 false ACPB
*a Air conditioning wire
(Inverter with Converter Assembly Side)
*b Tip of Terminal


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
U2-2 (ACPE) (Negative (-) probe) - U2-1 (ACPB) (Positive (+) probe) Power switch off 100 kΩ or higher


NOTICE:
·

Do not use a megohmmeter.

·

Read the resistance after the value has stabilized.

·

Be sure to inspect with connecting the tester probes to the tips of the terminal.




d.

Reconnect the air conditioning wire connector.


Result:
Proceed to
OK
NG



OK

3.CHECK HV FLOOR UNDER WIRE

NG

4.CHECK AIR CONDITIONING WIRE
3.CHECK HV FLOOR UNDER WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A376129

Disconnect the HV floor under wire connector from the inverter with converter assembly.


c.
A365608C08
0.677,0.49 1.135,0.75 0.458,0.26 1.052,1.083 1.635,0.688 true 2.667,1.104 1.979,0.688 true 0.083,0.042 0.396,0.198 0.313,0.156 10 false *a 0.771,0.99 1.083,1.146 0.313,0.156 10 false CBI 2.74,1.031 3.052,1.188 0.313,0.156 10 false CEI 0.813,0.531 1.125,0.688 0.313,0.156 10 false T1
*a HV Floor Under Wire
(Inverter with Converter Assembly Side)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T1-1 (CBI) - T1-2 (CEI) Power switch off 10 kΩ or higher


NOTICE:

Be sure not to damage or deform the terminal being inspected.



d.

Reconnect the HV floor under wire connector.


Result:
Proceed to
OK
NG



OK

NG

5.CHECK HV FLOOR UNDER WIRE
4.CHECK AIR CONDITIONING WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A376122

Disconnect the air conditioning wire connector from the inverter with converter assembly.


c.
A394768

Disconnect the U1 air conditioning wire from the compressor with motor assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>COMPRESSOR>REMOVAL


d.
A380308C06
0.5,0.583 0.813,0.781 0.313,0.198 1.427,0.688 0.667,1.24 true 1.677,0.688 2.406,1.323 true 2.729,0.563 2.49,0.906 2.49,0.906 3.01,0.656 true 0.063,0.063 0.375,0.219 0.313,0.156 10 false *a 2.354,0.906 2.667,1.063 0.313,0.156 10 true *b 0.563,0.594 0.875,0.75 0.313,0.156 10 false U2 0.51,1.281 0.927,1.469 0.417,0.188 10 false ACPE 2.292,1.354 2.708,1.542 0.417,0.188 10 false ACPB
*a Air conditioning wire
(Inverter with Converter Assembly Side)
*b Tip of Terminal


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
U2-2 (ACPE) - U2-1 (ACPB) Power switch off 10 kΩ or higher


NOTICE:

Be sure to inspect with connecting the tester probes to the tips of the terminal.



e.

Reconnect the air conditioning wire connector to the inverter with converter assembly.


f.

Reconnect the U1 air conditioning wire to the compressor with motor assembly.


Result:
Proceed to
OK
NG



OK

REPLACE COMPRESSOR WITH MOTOR ASSEMBLY

NG

REPLACE AIR CONDITIONING WIRE

5.CHECK HV FLOOR UNDER WIRE
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.
A376114

Disconnect the HV floor under wire connectors from the HV battery junction block assembly.


d.
A376129

Disconnect the HV floor under wire connector from the inverter with converter assembly.


e.
A365608C08
0.677,0.49 1.135,0.75 0.458,0.26 1.052,1.083 1.635,0.688 true 2.667,1.104 1.979,0.688 true 0.083,0.042 0.396,0.198 0.313,0.156 10 false *a 0.771,0.99 1.083,1.146 0.313,0.156 10 false CBI 2.74,1.031 3.052,1.188 0.313,0.156 10 false CEI 0.813,0.531 1.125,0.688 0.313,0.156 10 false T1
*a HV Floor Under Wire
(Inverter with Converter Assembly Side)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
T1-1 (CBI) - T1-2 (CEI) Power switch off 10 kΩ or higher


NOTICE:

Be sure not to damage or deform the terminal being inspected.



f.

Reconnect the HV floor under wire connector to the inverter with converter assembly.


g.

Reconnect the HV floor under wire connectors to the HV battery junction block assembly.


h.

Install the No. 1 HV battery cover panel RH.


Result:
Proceed to
OK
NG



OK

NG