Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404410 HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY) C

2ZR-FXE HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY)  P0E2D00  Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance  


DESCRIPTION

The battery ECU assembly detects the voltage of each HV battery cell. The battery ECU assembly monitors its internal HV battery cell voltage detection circuits to detect malfunctions. If the battery ECU assembly detects a malfunction it will store this DTC.

HINT:

If this DTC is output, it will be necessary to replace the battery ECU assembly.


DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0E2D00 Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance The battery ECU assembly detects a malfunction of its internal HV battery cell voltage detection circuits.
(1 trip detection logic)
·

Battery ECU assembly

·

No. 1 HV supply stack sub-assembly

·

No. 2 HV supply stack sub-assembly


Comes on Master Warning:
Comes on

Related Data List
DTC No. Data List
P0E2D00 Hybrid Battery Cell 1 to 56 Voltage

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With the vehicle stopped and the shift position in P, turn the power switch on (IG) and wait for at least 70 seconds.

7.

Turn the power switch on (READY) and without depressing the accelerator pedal, and while depressing the brake pedal, change the shift position to D and wait for 1 minutes. (Step A)

8.

Drive the vehicle 0.5 m (1.6 ft.) forward and perform step A.

9.

Drive the vehicle another 0.5 m (1.6 ft.) forward and perform step A. Repeat this procedure 5 times (minimum total driving distance: 2 m (6.6 ft.)).

10.

Enter the following menus: Powertrain / HV Battery / Utility / All Readiness.

11.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C02
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.

If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.

·
A358021C02
0.531,4.146 0.844,4.344 0.313,0.198 10 false *a 2.74,4.146 3.052,4.344 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

-

Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.


·

Before returning the HV battery, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HV BATTERY (for LITHIUM-ION BATTERY)>RECOVERY INSPECTION

·

Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HV BATTERY (for LITHIUM-ION BATTERY)>RECOVERY INSPECTION

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.

·
A358020

After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HV BATTERY, HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / HV Battery and Hybrid Control / Trouble Codes.


d.

Check for DTCs.

Powertrain > HV Battery > Trouble Codes
50001 398
Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
"P0E2D00" only is output, or DTCs except the ones in the table below are also output. A
DTCs of hybrid battery system in the table below are output. B
DTCs of hybrid control system in the table below are output. C


System Relevant DTC
Hybrid battery system P060A47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
P060B49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
P060687 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
P1A001C Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range
P301A1C Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range
Hybrid control system P0A1F94 Hybrid/EV Battery Energy Control Module Unexpected Operation
P0AA649 *1 Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure

*1: If area specific insulation resistance malfunction DTCs (P1C7C49, P1C7D49, P1C7E49 or P1C7F49) are output, perform repairs according to each DTC.


e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (BATTERY ECU ASSEMBLY CONNECTOR)

B

C

2.CHECK CONNECTOR CONNECTION CONDITION (BATTERY ECU ASSEMBLY CONNECTOR)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.
A380049N08
0.51,0.219 0.792,0.396 0.281,0.177 0.823,0.219 1.104,0.396 0.281,0.177 1.125,0.219 1.406,0.396 0.281,0.177 1.438,0.208 1.719,0.385 0.281,0.177 0.552,0.229 0.896,0.417 0.344,0.188 10 false z16 0.865,0.229 1.177,0.438 0.313,0.208 10 false z15 1.167,0.229 1.479,0.427 0.313,0.198 10 false z21 1.469,0.229 1.781,0.427 0.313,0.198 10 false z20

Check the connections of the battery ECU assembly connectors.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

The connector is connected securely and there are no contact problems.


Result:
Result Proceed to
OK A
Not connected securely The terminals are not damaged or corroded B
Either connector z15 or z16 was not connected securely The terminals are damaged or corroded C
Either connector z20 or z21 was not connected securely The terminals are damaged or corroded D



d.

Install the No. 1 HV battery protector.



A

3.CHECK FREEZE FRAME DATA

B

CONNECT SECURELY

C

D

3.CHECK FREEZE FRAME DATA
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / HV battery / Trouble Codes.


d.

Read the value of freeze frame data items "Hybrid Battery Cell 1 Voltage" through "Hybrid Battery Cell 56 Voltage" for DTC P0E2D00 and make a note if the value of any is 1.6 V or less.

Powertrain > HV Battery > Trouble Codes
50001 398
Result:
Result Proceed to
The value of any Hybrid Battery Cell 1 Voltage, Hybrid Battery Cell 2 Voltage, Hybrid Battery Cell 3 Voltage, Hybrid Battery Cell 4 Voltage, Hybrid Battery Cell 5 Voltage, Hybrid Battery Cell 6 Voltage, Hybrid Battery Cell 7 Voltage, Hybrid Battery Cell 8 Voltage, Hybrid Battery Cell 9 Voltage, Hybrid Battery Cell 10 Voltage, Hybrid Battery Cell 11 Voltage, Hybrid Battery Cell 12 Voltage, Hybrid Battery Cell 13 Voltage, Hybrid Battery Cell 14 Voltage, Hybrid Battery Cell 15 Voltage, Hybrid Battery Cell 16 Voltage, Hybrid Battery Cell 17 Voltage, Hybrid Battery Cell 18 Voltage, Hybrid Battery Cell 19 Voltage is 1.6 V or less A
The value of any Hybrid Battery Cell 20 Voltage, Hybrid Battery Cell 21 Voltage, Hybrid Battery Cell 22 Voltage, Hybrid Battery Cell 23 Voltage, Hybrid Battery Cell 24 Voltage, Hybrid Battery Cell 25 Voltage, Hybrid Battery Cell 26 Voltage, Hybrid Battery Cell 27 Voltage, Hybrid Battery Cell 28 Voltage is 1.6 V or less B
The value of any Hybrid Battery Cell 29 Voltage, Hybrid Battery Cell 30 Voltage, Hybrid Battery Cell 31 Voltage, Hybrid Battery Cell 32 Voltage, Hybrid Battery Cell 33 Voltage, Hybrid Battery Cell 34 Voltage, Hybrid Battery Cell 35 Voltage, Hybrid Battery Cell 36 Voltage, Hybrid Battery Cell 37 Voltage is 1.6 V or less C
The value of any Hybrid Battery Cell 38 Voltage, Hybrid Battery Cell 39 Voltage, Hybrid Battery Cell 40 Voltage, Hybrid Battery Cell 41 Voltage, Hybrid Battery Cell 42 Voltage, Hybrid Battery Cell 43 Voltage, Hybrid Battery Cell 44 Voltage, Hybrid Battery Cell 45 Voltage, Hybrid Battery Cell 46 Voltage, Hybrid Battery Cell 47 Voltage, Hybrid Battery Cell 48 Voltage, Hybrid Battery Cell 49 Voltage, Hybrid Battery Cell 50 Voltage, Hybrid Battery Cell 51 Voltage, Hybrid Battery Cell 52 Voltage, Hybrid Battery Cell 53 Voltage, Hybrid Battery Cell 54 Voltage, Hybrid Battery Cell 55 Voltage, Hybrid Battery Cell 56 Voltage is 1.6 V or less D
Other than above E



e.

Turn the power switch off.



A

4.CHECK NO. 1 HV SUPPLY STACK SUB-ASSEMBLY (HYBRID BATTERY CELL 1 TO 19 VOLTAGE)

B

5.CHECK NO. 1 HV SUPPLY STACK SUB-ASSEMBLY (HYBRID BATTERY CELL 20 TO 28 VOLTAGE)

C

8.CHECK NO. 2 HV SUPPLY STACK SUB-ASSEMBLY (HYBRID BATTERY CELL 29 TO 37 VOLTAGE)

D

9.CHECK NO. 2 HV SUPPLY STACK SUB-ASSEMBLY (HYBRID BATTERY CELL 38 TO 56 VOLTAGE)

E

4.CHECK NO. 1 HV SUPPLY STACK SUB-ASSEMBLY (HYBRID BATTERY CELL 1 TO 19 VOLTAGE)
CAUTION:
·

Be sure to wear insulated gloves and protective goggles.

·

Disconnect only the connector corresponding to the HV battery cell to be checked. Do not disconnect the other connectors.



NOTICE:

Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the voltage of each HV battery cell.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.

Disconnect the battery ECU assembly connector.


d.
A376392C09
1.5,2.01 1.885,2.271 0.385,0.26 2.135,3.417 2.396,3.417 true 2.135,3.24 2.396,3.24 true 2.135,3.042 2.396,3.042 true 2.156,3.594 2.417,3.594 true 1.896,3.635 2.083,4 true 1.958,3.469 2.292,3.969 true 2.271,2.708 1.948,3.156 true 2.271,2.521 1.948,2.969 true 1.729,3.667 1.99,4.229 true 1.667,3.458 1.594,4.24 true 1.573,2.479 1.667,3.156 true 1.833,2.458 1.771,2.979 true 1.51,3.646 1.365,4.354 true 1.479,3.458 1.24,4.198 true 1.135,2.656 1.51,3.146 true 1.177,2.5 1.521,3 true 0.792,3.583 1.271,3.583 true 0.802,3.406 1.281,3.406 true 0.802,3.25 1.281,3.25 true 0.813,3.042 1.292,3.042 true 0.75,1.969 1.281,2.313 0.531,0.344 10 false *a 2.438,3.531 2.969,3.823 0.531,0.292 10 false GA0 2.427,3.344 2.958,3.635 0.531,0.292 10 false VA1 2.427,3.177 2.958,3.469 0.531,0.292 10 false VA2 2.417,2.979 2.948,3.271 0.531,0.292 10 false VA3 2.031,4.042 2.563,4.333 0.531,0.292 10 false VA4 2.302,3.979 2.833,4.271 0.531,0.292 10 false VA5 2.344,2.646 2.875,2.938 0.531,0.292 10 false VA6 2.302,2.417 2.833,2.708 0.531,0.292 10 false VA7 1.906,4.26 2.438,4.552 0.531,0.292 10 false VA8 1.521,4.313 2.052,4.604 0.531,0.292 10 false VA9 1.354,2.313 1.885,2.604 0.531,0.292 10 false VA10 1.76,2.302 2.292,2.594 0.531,0.292 10 false VA11 1.177,4.396 1.625,4.656 0.448,0.26 10 false VA12 0.938,4.229 1.469,4.521 0.531,0.292 10 false VA13 0.792,2.604 1.323,2.896 0.531,0.292 10 false VA14 0.833,2.344 1.365,2.635 0.531,0.292 10 false VA15 0.458,3.531 0.99,3.823 0.531,0.292 10 false VA16 0.458,3.354 0.99,3.646 0.531,0.292 10 false VA17 0.458,3.188 0.99,3.479 0.531,0.292 10 false VA18 0.458,2.979 0.99,3.271 0.531,0.292 10 false VA19 1.594,2.052 2.125,2.344 0.531,0.292 10 false z20
*a Rear view of wire harness connector
(to Battery ECU Assembly)


Measure the voltage according to the value(s) in the table below.

HINT:

Measure the voltage of the HV battery cells whose value in the freeze frame data was 1.6 V or less only.


Hybrid Battery Cell Tester Connection Condition
1 z20-16 (GA0) - z20-11 (VA1) Always
2 z20-11 (VA1) - z20-6 (VA2) Always
3 z20-6 (VA2) - z20-1 (VA3) Always
4 z20-1 (VA3) - z20-17 (VA4) Always
5 z20-17 (VA4) - z20-12 (VA5) Always
6 z20-12 (VA5) - z20-7 (VA6) Always
7 z20-7 (VA6) - z20-2 (VA7) Always
8 z20-2 (VA7) - z20-18 (VA8) Always
9 z20-18 (VA8) - z20-13 (VA9) Always
10 z20-13 (VA9) - z20-8 (VA10) Always
11 z20-8 (VA10) - z20-3 (VA11) Always
12 z20-3 (VA11) - z20-19 (VA12) Always
13 z20-19 (VA12) - z20-14 (VA13) Always
14 z20-14 (VA13) - z20-9 (VA14) Always
15 z20-9 (VA14) - z20-4 (VA15) Always
16 z20-4 (VA15) - z20-20 (VA16) Always
17 z20-20 (VA16) - z20-15 (VA17) Always
18 z20-15 (VA17) - z20-10 (VA18) Always
19 z20-10 (VA18) - z20-5 (VA19) Always

CAUTION:

Make sure not to cross the electrodes of an electrical tester measurement terminals.


NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



Result:
Result Proceed to
The voltage between the terminals is 1.6 V or less. A
Other than above B


e.

Reconnect the battery ECU assembly connector.


f.

Install the No. 1 HV battery protector.



A

6.CHECK BATTERY ECU ASSEMBLY (GA0 - VA28)

B

5.CHECK NO. 1 HV SUPPLY STACK SUB-ASSEMBLY (HYBRID BATTERY CELL 20 TO 28 VOLTAGE)
CAUTION:
·

Be sure to wear insulated gloves and protective goggles.

·

Disconnect only the connector corresponding to the HV battery cell to be checked. Do not disconnect the other connectors.



NOTICE:

Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the voltage of each HV battery cell.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.

Disconnect the battery ECU assembly connector.


d.
A376393C08
1.51,2.177 1.938,2.469 0.427,0.292 2.094,3.656 2.604,3.656 true 2.083,3.458 2.594,3.458 true 2.073,3.281 2.583,3.281 true 1.823,3.74 1.99,4.26 true 1.885,3.521 2.073,4.125 true 1.625,3.74 1.521,4.281 true 1.583,3.531 1.344,4.125 true 0.844,3.677 1.354,3.677 true 0.844,3.479 1.354,3.479 true 0.865,3.281 1.375,3.281 true 0.896,1.99 1.292,2.26 0.396,0.271 10 false *a 2.635,3.583 3.125,3.927 0.49,0.344 10 false GA1 2.635,3.396 3.125,3.74 0.49,0.344 10 false VA20 2.635,3.24 3.125,3.583 0.49,0.344 10 false VA21 1.854,4.302 2.344,4.646 0.49,0.344 10 false VA22 2.042,4.167 2.531,4.51 0.49,0.344 10 false VA23 1.354,4.302 1.813,4.563 0.458,0.26 10 false VA24 1.073,4.146 1.563,4.49 0.49,0.344 10 false VA25 0.5,3.635 0.99,3.979 0.49,0.344 10 false VA26 0.5,3.427 0.99,3.771 0.49,0.344 10 false VA27 0.5,3.219 0.99,3.563 0.49,0.344 10 false VA28 1.625,2.229 2.115,2.573 0.49,0.344 10 false z21
*a Rear view of wire harness connector
(to Battery ECU Assembly)


Measure the voltage according to the value(s) in the table below.

HINT:

Measure the voltage of the HV battery cells whose value in the freeze frame data was 1.6 V or less only.


Hybrid Battery Cell Tester Connection Condition
20 z21-13 (GA1) - z21-9 (VA20) Always
20 z21-9 (VA20) - z21-5 (VA21) Always
22 z21-5 (VA21) - z21-14 (VA22) Always
23 z21-14 (VA22) - z21-10 (VA23) Always
24 z21-10 (VA23) - z21-15 (VA24) Always
25 z21-15 (VA24) - z21-11 (VA25) Always
26 z21-11 (VA25) - z21-16 (VA26) Always
27 z21-16 (VA26) - z21-12 (VA27) Always
28 z21-12 (VA27) - z21-8 (VA28) Always

CAUTION:

Make sure not to cross the electrodes of an electrical tester measurement terminals.


NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



Result:
Result Proceed to
The voltage between the terminals is 1.6 V or less. A
Other than above B


e.

Reconnect the battery ECU assembly connector.


f.

Install the No. 1 HV battery protector.



A

6.CHECK BATTERY ECU ASSEMBLY (GA0 - VA28)

B

6.CHECK BATTERY ECU ASSEMBLY (GA0 - VA28)
NOTICE:

Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance.



b.

Measure the resistance according to the value(s) in the table below.

HINT:

Only inspect the terminals of the battery ECU assembly which correspond to the HV battery cells which measured 1.6 V or less in the previous step.


A380052C11
5.385,3.323 5.792,3.552 0.406,0.229 1.708,3.271 2.115,3.5 0.406,0.229 6.198,5.5 6.573,6 true 6.198,5.177 6.5,5.177 true 6.198,4.927 6.5,4.927 true 6.188,4.615 6.552,4.115 true 5.875,5.5 5.979,6.438 true 5.938,5.25 6.281,6.26 true 5.938,4.854 6.333,3.885 true 6.167,3.75 5.854,4.573 true 5.625,5.51 5.604,6.385 true 5.552,5.25 5.25,6.438 true 5.458,3.844 5.542,4.875 true 5.802,3.823 5.688,4.635 true 5.021,6.292 5.302,5.49 true 4.927,6.125 5.302,5.25 true 4.865,3.885 5.292,4.865 true 5.042,3.771 5.344,4.583 true 4.542,5.844 5.042,5.49 true 4.385,5.198 5.021,5.198 true 4.385,4.958 5.021,4.958 true 4.385,4.24 5.042,4.656 true 2.344,5.167 2.979,5.167 true 2.354,5.5 2.708,5.885 true 2.365,4.854 2.917,4.365 true 2.031,6.177 2.031,5.5 true 2.542,6.177 2.104,5.281 true 1.792,5.521 1.708,6.167 true 1.719,5.281 1.417,6.188 true 1.479,5.51 1.146,5.927 true 0.813,5.208 1.448,5.208 true 0.75,4.385 1.448,4.875 true 5.469,3.354 6.094,3.802 0.625,0.448 10 false z20 6.521,6.042 6.969,6.365 0.448,0.323 10 false GA0 6.552,5.104 7,5.427 0.448,0.323 10 false VA1 6.552,4.865 7,5.188 0.448,0.323 10 false VA2 6.604,4.021 7.052,4.344 0.448,0.323 10 false VA3 5.875,6.49 6.323,6.813 0.448,0.323 10 false VA4 6.208,6.302 6.656,6.625 0.448,0.323 10 false VA5 6.375,3.792 6.823,4.115 0.448,0.323 10 false VA6 6.219,3.635 6.667,3.958 0.448,0.323 10 false VA7 5.469,6.469 5.917,6.792 0.448,0.323 10 false VA8 5.115,6.469 5.563,6.792 0.448,0.323 10 false VA9 5.177,3.667 5.625,3.99 0.448,0.323 10 false VA10 5.76,3.656 6.208,3.979 0.448,0.323 10 false VA11 4.781,6.323 5.229,6.646 0.448,0.323 10 false VA12 4.594,6.135 5.042,6.458 0.448,0.323 10 false VA13 4.521,3.792 4.969,4.115 0.448,0.323 10 false VA14 4.75,3.604 5.198,3.927 0.448,0.323 10 false VA15 4.24,5.885 4.688,6.208 0.448,0.323 10 false VA16 4.042,5.146 4.49,5.469 0.448,0.323 10 false VA17 4.052,4.906 4.5,5.229 0.448,0.323 10 false VA18 4.052,4.167 4.5,4.49 0.448,0.323 10 false VA19 1.781,3.302 2.406,3.75 0.625,0.448 10 false z21 3.01,5.094 3.458,5.417 0.448,0.323 10 false VA20 2.75,5.865 3.198,6.188 0.448,0.323 10 false GA1 2.979,4.292 3.427,4.615 0.448,0.323 10 false VA21 1.896,6.208 2.344,6.531 0.448,0.323 10 false VA22 2.417,6.208 2.865,6.531 0.448,0.323 10 false VA23 1.531,6.208 1.979,6.531 0.448,0.323 10 false VA24 1.156,6.219 1.604,6.542 0.448,0.323 10 false VA25 0.917,6 1.365,6.323 0.448,0.323 10 false VA26 0.49,5.146 0.938,5.469 0.448,0.323 10 false VA27 0.417,4.302 0.865,4.625 0.448,0.323 10 false VA28 0.354,0.229 0.896,0.771 0.542,0.542 10 false *a
*a Component without harness connected
(Battery ECU Assembly)
- -


Standard Resistance:
Hybrid Battery Cell Tester Connection
(Tester Probe Polarity)
Condition Specified Condition
1 z20-16 (GA0) (-) - z20-11 (VA1) (+) Always 50 kΩ or more
2 z20-11 (VA1) (-) - z20-6 (VA2) (+) Always 50 kΩ or more
3 z20-6 (VA2) (-) - z20-1 (VA3) (+) Always 50 kΩ or more
4 z20-1 (VA3) (-) - z20-17 (VA4) (+) Always 50 kΩ or more
5 z20-17 (VA4) (-) - z20-12 (VA5) (+) Always 50 kΩ or more
6 z20-12 (VA5) (-) - z20-7 (VA6) (+) Always 50 kΩ or more
7 z20-7 (VA6) (-) - z20-2 (VA7) (+) Always 50 kΩ or more
8 z20-2 (VA7) (-) - z20-18 (VA8) (+) Always 50 kΩ or more
9 z20-18 (VA8) (-) - z20-13 (VA9) (+) Always 50 kΩ or more
10 z20-13 (VA9) (-) - z20-8 (VA10) (+) Always 50 kΩ or more
11 z20-8 (VA10) (-) - z20-3 (VA11) (+) Always 50 kΩ or more
12 z20-3 (VA11) (-) - z20-19 (VA12) (+) Always 50 kΩ or more
13 z20-19 (VA12) (-) - z20-14 (VA13) (+) Always 50 kΩ or more
14 z20-14 (VA13) (-) - z20-9 (VA14) (+) Always 50 kΩ or more
15 z20-9 (VA14) (-) - z20-4 (VA15) (+) Always 50 kΩ or more
16 z20-4 (VA15) (-) - z20-20 (VA16) (+) Always 50 kΩ or more
17 z20-20 (VA16) (-) - z20-15 (VA17) (+) Always 50 kΩ or more
18 z20-15 (VA17) (-) - z20-10 (VA18) (+) Always 50 kΩ or more
19 z20-10 (VA18) (-) - z20-5 (VA19) (+) Always 50 kΩ or more
20 z21-13 (GA1) (-) - z21-9 (VA20) (+) Always 50 kΩ or more
21 z21-9 (VA20) (-) - z21-5 (VA21) (+) Always 50 kΩ or more
22 z21-5 (VA21) (-) - z21-14 (VA22) (+) Always 50 kΩ or more
23 z21-14 (VA22) (-) - z21-10 (VA23) (+) Always 50 kΩ or more
24 z21-10 (VA23) (-) - z21-15 (VA24) (+) Always 50 kΩ or more
25 z21-15 (VA24) (-) - z21-11 (VA25) (+) Always 50 kΩ or more
26 z21-11 (VA25) (-) - z21-16 (VA26) (+) Always 50 kΩ or more
27 z21-16 (VA26) (-) - z21-12 (VA27) (+) Always 50 kΩ or more
28 z21-12 (VA27) (-) - z21-8 (VA28) (+) Always 50 kΩ or more


NOTICE:
·

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.

·

Read the resistance after the value has stabilized.

·

In order to avoid damaging the terminals of the battery ECU assembly, make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance of the battery ECU assembly.




c.

Install the battery ECU assembly.


Result:
Result Proceed to
The voltage between the terminals is 50 kΩ or more. A
Other than above B



A

B

7.REPLACE NO. 1 HV SUPPLY STACK SUB-ASSEMBLY
8.CHECK NO. 2 HV SUPPLY STACK SUB-ASSEMBLY (HYBRID BATTERY CELL 29 TO 37 VOLTAGE)
CAUTION:
·

Be sure to wear insulated gloves and protective goggles.

·

Disconnect only the connector corresponding to the HV battery cell to be checked. Do not disconnect the other connectors.



NOTICE:

Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the voltage of each HV battery cell.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.

Disconnect the battery ECU assembly connector.


d.
A376394C08
1.51,2.271 1.938,2.51 0.427,0.24 2.073,3.271 2.625,3.271 true 2.073,3.469 2.625,3.469 true 2.073,3.667 2.625,3.667 true 1.854,3.542 2.24,4.156 true 1.438,4.208 1.573,3.531 true 1.979,4.292 1.833,3.74 true 1.656,4.375 1.635,3.74 true 0.823,3.292 1.375,3.292 true 0.813,3.49 1.365,3.49 true 0.813,3.688 1.365,3.688 true 0.885,2.052 1.302,2.448 0.417,0.396 10 false *a 2.646,3.198 3.219,3.604 0.573,0.406 10 false VAD 2.656,3.406 3.229,3.813 0.573,0.406 10 false VA29 2.656,3.604 3.229,4.01 0.573,0.406 10 false VA30 2.219,4.156 2.802,4.427 0.583,0.271 10 false VA31 1.854,4.313 2.438,4.583 0.583,0.271 10 false VA32 1.229,4.229 1.813,4.5 0.583,0.271 10 false VA33 1.49,4.406 1.969,4.625 0.479,0.219 10 false VA34 0.469,3.219 0.948,3.438 0.479,0.219 10 false VA35 0.458,3.417 0.938,3.635 0.479,0.219 10 false VA36 0.438,3.615 0.917,3.833 0.479,0.219 10 false VA37 1.625,2.302 2.073,2.792 0.448,0.49 10 false z15
*a Rear view of wire harness connector
(to Battery ECU Assembly)


Measure the voltage according to the value(s) in the table below.

HINT:

Measure the voltage of the HV battery cells whose value in the freeze frame data was 1.6 V or less only.


Hybrid Battery Cell Tester Connection Condition
29 z15-5 (VAD) - z15-9 (VA29) Always
30 z15-9 (VA29) - z15-13 (VA30) Always
31 z15-13 (VA30) - z15-10 (VA31) Always
32 z15-10 (VA31) - z15-14 (VA32) Always
33 z15-14 (VA32) - z15-11 (VA33) Always
34 z15-11 (VA33) - z15-15 (VA34) Always
35 z15-15 (VA34) - z15-8 (VA35) Always
36 z15-8 (VA35) - z15-12 (VA36) Always
37 z15-12 (VA36) - z15-16 (VA37) Always

CAUTION:

Make sure not to cross the electrodes of an electrical tester measurement terminals.


NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



Result:
Result Proceed to
The voltage between the terminals is 1.6 V or less. A
Other than above B


e.

Reconnect the battery ECU assembly connector.


f.

Install the No. 1 HV battery protector.



A

10.CHECK BATTERY ECU ASSEMBLY (VAD - VA56)

B

9.CHECK NO. 2 HV SUPPLY STACK SUB-ASSEMBLY (HYBRID BATTERY CELL 38 TO 56 VOLTAGE)
CAUTION:
·

Be sure to wear insulated gloves and protective goggles.

·

Disconnect only the connector corresponding to the HV battery cell to be checked. Do not disconnect the other connectors.



NOTICE:

Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the voltage of each HV battery cell.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.

Disconnect the battery ECU assembly connector.


d.
A376395C08
1.521,1.969 1.917,2.177 0.396,0.208 1.938,2.896 2.104,2.323 true 2.188,2.958 2.531,2.958 true 2.198,3.177 2.542,3.177 true 2.198,3.375 2.542,3.375 true 2.198,3.583 2.542,3.583 true 2,3.427 2.188,4.042 true 1.938,3.656 2.063,4.188 true 1.729,2.875 1.74,2.354 true 1.979,3.104 2.323,2.417 true 1.667,3.135 1.469,2.333 true 1.667,3.427 1.531,4.177 true 1.729,3.635 1.729,4.323 true 1.469,2.906 1.146,2.354 true 1.458,3.115 1.083,2.5 true 1.458,3.438 1.26,4.042 true 1.458,3.635 1.271,4.354 true 1.24,2.99 0.875,2.99 true 1.24,3.188 0.875,3.188 true 1.24,3.396 0.875,3.396 true 1.25,3.583 0.885,3.583 true 0.927,1.99 1.469,2.479 0.542,0.49 10 false *a 2.573,2.865 3.125,3.417 0.552,0.552 10 false GA2 2.583,3.094 3.135,3.646 0.552,0.552 10 false VA38 2.583,3.302 3.135,3.854 0.552,0.552 10 false VA39 2.583,3.521 3.135,4.073 0.552,0.552 10 false VA40 2.115,2.208 2.667,2.76 0.552,0.552 10 false VA41 2.375,2.333 2.927,2.885 0.552,0.552 10 false VA42 2.229,4.031 2.75,4.271 0.521,0.24 10 false VA43 1.99,4.229 2.51,4.469 0.521,0.24 10 false VA44 1.583,2.188 2.135,2.74 0.552,0.552 10 false VA45 1.156,2.146 1.708,2.698 0.552,0.552 10 false VA46 1.344,4.219 1.719,4.448 0.375,0.229 10 true VA47 1.615,4.354 1.99,4.635 0.375,0.281 10 false VA48 0.792,2.24 1.344,2.792 0.552,0.552 10 false VA49 0.729,2.438 1.281,2.99 0.552,0.552 10 false VA50 0.927,4.052 1.302,4.281 0.375,0.229 10 false VA51 1.052,4.385 1.51,4.604 0.458,0.219 10 true VA52 0.542,2.927 1.094,3.479 0.552,0.552 10 false VA53 0.552,3.125 1.104,3.677 0.552,0.552 10 false VA54 0.552,3.333 1.104,3.885 0.552,0.552 10 false VA55 0.563,3.531 1.115,4.083 0.552,0.552 10 false VA56 1.625,1.99 2.177,2.542 0.552,0.552 10 false z16
*a Rear view of wire harness connector
(to Battery ECU Assembly)


Measure the voltage according to the value(s) in the table below.

HINT:

Measure the voltage of the HV battery cells whose value in the freeze frame data was 1.6 V or less only.


Hybrid Battery Cell Tester Connection Condition
38 z16-1 (GA2) - z16-6 (VA38) Always
39 z16-6 (VA38) - z16-11 (VA39) Always
40 z16-11 (VA39) - z16-16 (VA40) Always
41 z16-16 (VA40) - z16-2 (VA41) Always
42 z16-2 (VA41) - z16-7 (VA42) Always
43 z16-7 (VA42) - z16-12 (VA43) Always
44 z16-12 (VA43) - z16-17 (VA44) Always
45 z16-17 (VA44) - z16-3 (VA45) Always
46 z16-3 (VA45) - z16-8 (VA46) Always
47 z16-8 (VA46) - z16-13 (VA47) Always
48 z16-13 (VA47) - z16-18 (VA48) Always
49 z16-18 (VA48) - z16-4 (VA49) Always
50 z16-4 (VA49) - z16-9 (VA50) Always
51 z16-9 (VA50) - z16-14 (VA51) Always
52 z16-14 (VA51) - z16-19 (VA52) Always
53 z16-19 (VA52) - z16-5 (VA53) Always
54 z16-5 (VA53) - z16-10 (VA54) Always
55 z16-10 (VA54) - z16-15 (VA55) Always
56 z16-15 (VA55) - z16-20 (VA56) Always

CAUTION:

Make sure not to cross the electrodes of an electrical tester measurement terminals.


NOTICE:

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.



Result:
Result Proceed to
The voltage between the terminals is 1.6 V or less. A
Other than above B


e.

Reconnect the battery ECU assembly connector.


f.

Install the No. 1 HV battery protector.



A

10.CHECK BATTERY ECU ASSEMBLY (VAD - VA56)

B

10.CHECK BATTERY ECU ASSEMBLY (VAD - VA56)
NOTICE:

Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance.



b.

Measure the resistance according to the value(s) in the table below.

HINT:

Only inspect the terminals of the battery ECU assembly which correspond to the HV battery cells which measured 1.6 V or less in the previous step.


A380051C10
1.906,3.667 2.323,3.938 0.417,0.271 4.958,3.698 5.375,3.969 0.417,0.271 5.635,5.052 6.094,5.052 true 5.625,5.292 6.104,5.292 true 5.646,5.594 6.083,5.938 true 5.646,5.594 6.083,5.938 true 4.969,5.354 4.833,6.26 true 5.396,5.375 5.563,5.99 true 5.302,5.625 5.385,6.302 true 5.073,5.615 5.063,6.25 true 4.25,5.052 4.708,5.052 true 4.26,5.313 4.719,5.313 true 4.198,5.896 4.708,5.604 true 2.719,5.052 3.177,5.052 true 2.708,5.281 3.167,5.281 true 2.719,5.594 3.156,5.938 true 2.469,4.719 2.833,4.323 true 2.469,4.99 3.01,4.781 true 2.469,5.344 2.792,6.219 true 2.375,5.604 2.417,6.281 true 2.177,4.719 2.375,4.208 true 2.094,4.938 1.854,4.24 true 2.052,5.354 1.885,6.323 true 2.146,5.615 2.146,6.5 true 1.844,4.729 1.448,4.271 true 1.813,4.958 1.167,4.802 true 1.823,5.365 1.479,6.24 true 1.854,5.615 1.615,6.521 true 1.563,4.698 1.177,4.542 true 1.083,5.063 1.542,5.063 true 1.063,5.417 1.542,5.271 true 1.042,5.969 1.583,5.594 true 2.698,4.74 3.281,4.49 true 2.021,3.719 2.365,4.01 0.344,0.292 10 false z16 5.063,3.75 5.375,3.948 0.313,0.198 10 false z15 6.156,4.979 6.677,5.406 0.521,0.427 10 false VAD 6.167,5.26 6.688,5.688 0.521,0.427 10 false VA29 6.073,5.938 6.594,6.365 0.521,0.427 10 false VA30 5.531,6.031 6.052,6.458 0.521,0.427 10 false VA31 5.302,6.344 5.823,6.771 0.521,0.427 10 false VA32 4.521,6.281 5.042,6.708 0.521,0.427 10 false VA33 4.906,6.302 5.427,6.729 0.521,0.427 10 false VA34 3.906,5 4.427,5.427 0.521,0.427 10 false VA35 3.927,5.281 4.448,5.708 0.521,0.427 10 false VA36 3.875,5.938 4.396,6.365 0.521,0.427 10 false VA37 3.25,4.99 3.771,5.417 0.521,0.427 10 false VA38 3.25,5.198 3.771,5.625 0.521,0.427 10 false VA39 3.198,5.896 3.719,6.323 0.521,0.427 10 false VA40 2.906,4.25 3.427,4.677 0.521,0.427 10 false VA41 3.104,4.698 3.625,5.125 0.521,0.427 10 false VA42 2.75,6.24 3.271,6.667 0.521,0.427 10 false VA43 2.302,6.333 2.823,6.615 0.521,0.281 10 false VA44 2.458,4.094 2.979,4.521 0.521,0.427 10 false VA45 1.552,4.063 2.073,4.49 0.521,0.427 10 false VA46 1.708,6.354 2.229,6.635 0.521,0.281 10 false VA47 2.021,6.531 2.531,6.76 0.51,0.229 10 false VA48 1.094,4.177 1.615,4.604 0.521,0.427 10 false VA49 1.188,6.281 1.708,6.563 0.521,0.281 10 false VA51 0.833,4.729 1.354,5.01 0.521,0.281 10 false VA50 1.458,6.563 1.865,6.781 0.406,0.219 10 false VA52 0.823,4.469 1.344,4.75 0.521,0.281 10 false VA53 0.74,5.031 1.26,5.313 0.521,0.281 10 false VA54 0.688,5.948 1.208,6.229 0.521,0.281 10 false VA56 3.313,4.396 3.833,4.823 0.521,0.427 10 false GA2 0.719,5.406 1.24,5.688 0.521,0.281 10 false VA55 0.26,0.156 0.771,0.708 0.51,0.552 11 false *a
*a Component without harness connected
(Battery ECU Assembly)
- -


Standard Resistance:
Tester Connection
(Tester Probe Polarity)
Hybrid Battery Cell Condition Specified Condition
z15-5 (VAD) (-) - z15-9 (VA29) (+) 29 Always 50 kΩ or more
z15-9 (VA29) (-) - z15-13 (VA30) (+) 30 Always 50 kΩ or more
z15-13 (VA30) (-) - z15-10 (VA31) (+) 31 Always 50 kΩ or more
z15-10 (VA31) (-) - z15-14 (VA32) (+) 32 Always 50 kΩ or more
z15-14 (VA32) (-) - z15-11 (VA33) (+) 33 Always 50 kΩ or more
z15-11 (VA33) (-) - z15-15 (VA34) (+) 34 Always 50 kΩ or more
z15-15 (VA34) (-) - z15-8 (VA35) (+) 35 Always 50 kΩ or more
z15-8 (VA35) (-) - z15-12 (VA36) (+) 36 Always 50 kΩ or more
z15-12 (VA36) (-) - z15-16 (VA37) (+) 37 Always 50 kΩ or more
z16-1 (GA2) (-) - z16-6 (VA38) (+) 38 Always 50 kΩ or more
z16-6 (VA38) (-) - z16-11 (VA39) (+) 39 Always 50 kΩ or more
z16-11 (VA39) (-) - z16-16 (VA40) (+) 40 Always 50 kΩ or more
z16-16 (VA40) (-) - z16-2 (VA41) (+) 41 Always 50 kΩ or more
z16-2 (VA41) (-) - z16-7 (VA42) (+) 42 Always 50 kΩ or more
z16-7 (VA42) (-) - z16-12 (VA43) (+) 43 Always 50 kΩ or more
z16-12 (VA43) (-) - z16-17 (VA44) (+) 44 Always 50 kΩ or more
z16-17 (VA44) (-) - z16-3 (VA45) (+) 45 Always 50 kΩ or more
z16-3 (VA45) (-) - z16-8 (VA46) (+) 46 Always 50 kΩ or more
z16-8 (VA46) (-) - z16-13 (VA47) (+) 47 Always 50 kΩ or more
z16-13 (VA47) (-) - z16-18 (VA48) (+) 48 Always 50 kΩ or more
z16-18 (VA48) (-) - z16-4 (VA49) (+) 49 Always 50 kΩ or more
z16-4 (VA49) (-) - z16-9 (VA50) (+) 50 Always 50 kΩ or more
z16-9 (VA50) (-) - z16-14 (VA51) (+) 51 Always 50 kΩ or more
z16-14 (VA51) (-) - z16-19 (VA52) (+) 52 Always 50 kΩ or more
z16-19 (VA52) (-) - z16-5 (VA53) (+) 53 Always 50 kΩ or more
z16-5 (VA53) (-) - z16-10 (VA54) (+) 54 Always 50 kΩ or more
z16-10 (VA54) (-) - z16-15 (VA55) (+) 55 Always 50 kΩ or more
z16-15 (VA55) (-) - z16-20 (VA56) (+) 56 Always 50 kΩ or more


NOTICE:
·

Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.

·

Read the resistance after the value has stabilized.

·

In order to avoid damaging the terminals of the battery ECU assembly, make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance of the battery ECU assembly.




c.

Install the battery ECU assembly.


Result:
Result Proceed to
The voltage between the terminals is 50 kΩ or more. A
Other than above B



A

B

11.REPLACE NO. 2 HV SUPPLY STACK SUB-ASSEMBLY