The HV battery is composed of 56 cells (3.6 V each) in series. The battery ECU assembly monitors the voltage of each HV battery cell to detect malfunctions of the HV battery.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range | An open is detected in the HV battery cell voltage detection circuits of the No. 2 HV supply stack sub-assembly.
(1 trip detection logic) |
·
No. 2 HV supply stack sub-assembly ·
Battery ECU assembly |
Comes on | Master Warning:
Comes on |
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range | An open is detected in the HV battery cell voltage detection circuits of the No. 1 HV supply stack sub-assembly.
(1 trip detection logic) |
·
No. 1 HV supply stack sub-assembly ·
Battery ECU assembly |
Comes on | Master Warning:
Comes on |
| DTC No. | Data List |
|---|---|
| P1A001C | Hybrid Battery Cell 1 to 56 Voltage |
| P301A1C |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
With power switch on (IG) and wait for 10 seconds or more.
Enter the following menus: Powertrain / HV Battery / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
| *a | Dealer |
| *b | Battery Collection Agent |
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.
Before returning the HV battery, make sure to perform a recovery inspection.
Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.
After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / HV Battery and Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| "P1A001C or P301A1C" only is output, or DTCs except the ones in the table below are also output. | A |
| DTCs of hybrid battery system in the table below are output. | B |
| DTCs of hybrid control system in the table below are output. | C |
| System | Relevant DTC | |
|---|---|---|
| Hybrid battery system | P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | |
| Hybrid control system | P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
Turn the power switch off.
A
B
C
Check the DTCs that were output when the vehicle was brought to the workshop.
| Result | Proceed to |
|---|---|
| "P1A001C" is also output. | A |
| "P301A1C" is also output. | B |
A
B
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery protector.
Check the connections of the battery ECU assembly connectors.
The connector is connected securely and there are no contact problems.
Install the No. 1 HV battery protector.
| Result | Proceed to | |
|---|---|---|
| OK | A | |
| Not connected securely | The terminals are not damaged or corroded | B |
| Not connected securely | The terminals are damaged or corroded | C |
A
B
C
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / HV battery / Trouble Codes.
Read the value of freeze frame data items "Hybrid Battery Cell 29 Voltage" through "Hybrid Battery Cell 56 Voltage" for DTC P1A001C and make a note if the value of any is 1.6 V or less.
Turn the power switch off.
| Result | Proceed to |
|---|---|
| The value of any Hybrid Battery Cell 29 Voltage, Hybrid Battery Cell 30 Voltage, Hybrid Battery Cell 31 Voltage, Hybrid Battery Cell 32 Voltage, Hybrid Battery Cell 33 Voltage, Hybrid Battery Cell 34 Voltage, Hybrid Battery Cell 35 Voltage, Hybrid Battery Cell 36 Voltage, Hybrid Battery Cell 37 Voltage is 1.6 V or less | A |
| The value of any Hybrid Battery Cell 38 Voltage, Hybrid Battery Cell 39 Voltage, Hybrid Battery Cell 40 Voltage, Hybrid Battery Cell 41 Voltage, Hybrid Battery Cell 42 Voltage, Hybrid Battery Cell 43 Voltage, Hybrid Battery Cell 44 Voltage, Hybrid Battery Cell 45 Voltage, Hybrid Battery Cell 46 Voltage, Hybrid Battery Cell 47 Voltage, Hybrid Battery Cell 48 Voltage, Hybrid Battery Cell 49 Voltage, Hybrid Battery Cell 50 Voltage, Hybrid Battery Cell 51 Voltage, Hybrid Battery Cell 52 Voltage, Hybrid Battery Cell 53 Voltage, Hybrid Battery Cell 54 Voltage, Hybrid Battery Cell 55 Voltage, Hybrid Battery Cell 56 Voltage is 1.6 V or less | B |
A
B
| Result | Proceed to |
|---|---|
| The voltage between the terminals is 1.6 V or less. | A |
| Other than above | B |
A
B
| Result | Proceed to |
|---|---|
| The voltage between the terminals is 1.6 V or less. | A |
| Other than above | B |
A
B
Be sure to wear insulated gloves and protective goggles.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 HV battery protector.
Check the connections of the battery ECU assembly connectors.
The connector is connected securely and there are no contact problems.
| Result | Proceed to | |
|---|---|---|
| OK | A | |
| Not connected securely | The terminals are not damaged or corroded | B |
| Not connected securely | The terminals are damaged or corroded | C |
Install the No. 1 HV battery protector.
A
B
C
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / HV battery / Trouble Codes.
Read the value of freeze frame data items "Hybrid battery cell 1 voltage" through "Hybrid battery cell 28 voltage" for DTC P301A1C and make a note if the value of any is 1.6 V or less.
Turn the power switch off.
| Result | Proceed to |
|---|---|
| The value of any Hybrid battery cell 1 voltage, Hybrid battery cell 2 voltage, Hybrid battery cell 3 voltage, Hybrid battery cell 4 voltage, Hybrid battery cell 5 voltage, Hybrid battery cell 6 voltage, Hybrid battery cell 7 voltage, Hybrid battery cell 8 voltage, Hybrid battery cell 9 voltage, Hybrid battery cell 10 voltage, Hybrid battery cell 11 voltage, Hybrid battery cell 12 voltage, Hybrid battery cell 13 voltage, Hybrid battery cell 14 voltage, Hybrid battery cell 15 voltage, Hybrid battery cell 16 voltage, Hybrid battery cell 17 voltage, Hybrid battery cell 18 voltage, Hybrid battery cell 19 voltage is 1.6 V or less | A |
| The value of any Hybrid battery cell 20 voltage, Hybrid battery cell 21 voltage, Hybrid battery cell 22 voltage, Hybrid battery cell 23 voltage, Hybrid battery cell 24 voltage, Hybrid battery cell 25 voltage, Hybrid battery cell 26 voltage, Hybrid battery cell 27 voltage, Hybrid battery cell 28 voltage is 1.6 V or less | B |
A
B
| Result | Proceed to |
|---|---|
| The voltage between the terminals is 1.6 V or less. | A |
| Other than above | B |
A
B
| Result | Proceed to |
|---|---|
| The voltage between the terminals is 1.6 V or less. | A |
| Other than above | B |
A
B