Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404410 HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY) C

2ZR-FXE HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY)  P1A8100  Hybrid/EV Battery Stack 1 Delta SOC High (Extreme)  P1A8600  Hybrid/EV Battery Stack 2 Delta SOC High (Extreme)  


DESCRIPTION

The HV battery is composed of 56 cells (3.6 V each) in series. The battery ECU assembly monitors the difference in capacity of each HV battery cell to detect malfunctions of the HV battery.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P1A8100 Hybrid/EV Battery Stack 1 Delta SOC High (Extreme) The difference in capacity of each cell of the No. 1 HV supply stack sub-assembly exceeds the specified value excessively.
(1 trip detection logic)
·

No. 1 HV supply stack sub-assembly

·

Battery ECU assembly

·

Hybrid battery terminal block


Comes on Master Warning:
Comes on
P1A8600 Hybrid/EV Battery Stack 2 Delta SOC High (Extreme) The difference in capacity of each cell of the No. 2 HV supply stack sub-assembly exceeds the specified value excessively.
(1 trip detection logic)
·

No. 2 HV supply stack sub-assembly

·

Battery ECU assembly

·

Hybrid battery terminal block


Comes on Master Warning:
Comes on

Related Data List
DTC No. Data List
P1A8100
·

Hybrid Battery Cell 1 to 56 Voltage

·

Hybrid Battery Cell 1 to 56 Internal Resistance

·

Hybrid Battery SOC

·

Hybrid Battery Current

·

Hybrid Battery Voltage


P1A8100

HINT:

These DTCs can be stored after clearing the DTCs and driving the vehicle for approximately 10 minutes.


CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Drive the vehicle on urban roads for approximately 10 minutes.

7.

Enter the following menus: Powertrain / HV Battery / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C02
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.

If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.

·
A358021C02
0.531,4.146 0.844,4.344 0.313,0.198 10 false *a 2.74,4.146 3.052,4.344 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

-

Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.


·

Before returning the HV battery, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HV BATTERY (for LITHIUM-ION BATTERY)>RECOVERY INSPECTION

·

Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HV BATTERY (for LITHIUM-ION BATTERY)>RECOVERY INSPECTION

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.

·
A358020

After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HV BATTERY, HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / HV Battery and Hybrid Control / Trouble Codes.


d.

Check for DTCs.

Powertrain > HV Battery > Trouble Codes
50001 398
Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
"P1A8100 or P1A8600" only is output, or DTCs except the ones in the table below are also output. A
DTCs of hybrid battery system in the table below are output. B
DTCs of hybrid control system in the table below are output. C


System Relevant DTC
Hybrid battery system P060A47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
P060B49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
P060687 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
P0ABF28 Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure
P0ABF2A Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range
P1CBB12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery
P1CBB14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open
P1CC81E Hybrid/EV Battery Stack 1 Voltage Difference Out of Range
P1CC91E Hybrid/EV Battery Stack 2 Voltage Difference Out of Range
Hybrid control system P0A1F94 Hybrid/EV Battery Energy Control Module Unexpected Operation
P0B231C Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range
P1C2D62 Hybrid/EV Battery "A" Voltage Sensor/ Boosting Converter Voltage Sensor "A" Signal Compare Failure


e.

Turn the power switch off.



A

2.CHECK DTC

B

C

2.CHECK DTC
a.

Check the DTCs that were output when the vehicle was brought to the workshop.


Result:
Result Proceed to
"P1A8100" is also output. A
"P1A8600" is also output. B



A

3.CHECK FREEZE FRAME DATA

B

7.CHECK FREEZE FRAME DATA
3.CHECK FREEZE FRAME DATA
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / HV battery / Trouble Codes.


d.

Read the value of freeze frame data items "HV battery cell 1 voltage" through "HV battery cell 28 voltage" for DTC P1A8100 and make a note if the value of any is the lowest voltage value.

Powertrain > HV Battery > Trouble Codes
50001 398

e.

Turn the power switch off.


Result:
Proceed to
NEXT



NEXT

4.CHECK BATTERY ECU ASSEMBLY (GA0 - VA28)
4.CHECK BATTERY ECU ASSEMBLY (GA0 - VA28)

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>P1A8000

Result:
Result Proceed to
The voltage between the terminals is 50 kΩ or more. A
Other than above B



A

5.CHECK TOTAL DISTANCE DRIVEN

B

5.CHECK TOTAL DISTANCE DRIVEN
a.

Read the odometer to check the total distance the vehicle has been driven.


Result:
Result Proceed to
Total distance driven is less than 200000 km (124280 mile) A
Total distance driven is 200000 km (124280 mile) or more Current total distance driven - total distance driven when hybrid battery terminal block replaced = less than 200000 km (124280 mile) *1
Other than above B


HINT:

*1: If the hybrid battery terminal block has been replaced, use the total distance driven since it was replaced.



A

B

6.REPLACE NO. 1 HV SUPPLY STACK SUB-ASSEMBLY
7.CHECK FREEZE FRAME DATA
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / HV battery / Trouble Codes.


d.

Read the value of freeze frame data items "HV battery cell 29 voltage" through "HV battery cell 56 voltage" for DTC P1A8600 and make a note if the value of any is the lowest voltage value.

Powertrain > HV Battery > Trouble Codes
50001 398

e.

Turn the power switch off.


Result:
Proceed to
NEXT



NEXT

8.CHECK BATTERY ECU ASSEMBLY (VAD - VA56)
8.CHECK BATTERY ECU ASSEMBLY (VAD - VA56)

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>P1A8000

Result:
Result Proceed to
The voltage between the terminals is 50 kΩ or more. A
Other than above B



A

9.CHECK TOTAL DISTANCE DRIVEN

B

9.CHECK TOTAL DISTANCE DRIVEN
a.

Read the odometer to check the total distance the vehicle has been driven.


Result:
Result Proceed to
Total distance driven is less than 200000 km (124280 mile) A
Total distance driven is 200000 km (124280 mile) or more Current total distance driven - total distance driven when hybrid battery terminal block replaced = less than 200000 km (124280 mile) *1
Other than above B


HINT:

*1: If the hybrid battery terminal block has been replaced, use the total distance driven since it was replaced.



A

B

10.REPLACE NO. 2 HV SUPPLY STACK SUB-ASSEMBLY