The hybrid vehicle control ECU monitors its internal operation and detects the following malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P30004B | Hybrid/EV Battery Control System Over Temperature | The HV battery temperature becomes too high due to a malfunction in the HV system.
(1 trip detection logic) |
·
Hybrid vehicle control ECU ·
HV battery ·
Battery voltage sensor |
Does not come on | Master Warning: Comes on |
| DTC No. | Data List |
|---|---|
| P30004B | ·
Hybrid Battery Temperature 1 to 3 ·
Hybrid Battery Cooling Fan Intake Air Temperature 1 ·
Ambient Temperature ·
Hybrid Battery Current ·
Hybrid Battery SOC ·
Hybrid Battery Cooling Fan 1 Drive Status ·
Hybrid Battery Cooling Fan |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>UTILITY
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
Drive the vehicle for approximately 10 minutes according to the freeze frame data items "Vehicle Speed", "Hybrid Battery Temperature 1 to 3", "Hybrid Battery Cooling Fan Intake Air Temperature 1", "Ambient Temperature" and "Hybrid Battery Current".
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
| *a | Dealer |
| *b | Battery Collection Agent |
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.
After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P30004B only is output. | A |
| DTCs other than P30004B are also output. | B |
Turn the power switch off.
A
B
| *a | Intake Port |
Check the HV battery cooling system intake port for blockage.
If anything is blocking the HV battery cooling system intake port, remove it.
Clean the No. 1 HV battery intake filter.
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>BATTERY COOLING FILTER>INSPECTION
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read the freeze frame data of DTC P30004B.
| *a | Freeze Frame Data Recorded |
| *b | DTC Stored |
| *c | Time |
Although freeze frame data is recorded before and after a DTC is stored, for this step it is only necessary to read the freeze frame data recorded before "0s" (when the DTC was stored).
| Result | Proceed to |
|---|---|
| Other than below | A |
| The difference between the value of "VL-Voltage before Boosting" and the total of "Hybrid Battery Block 1 to 10 Voltage" is 10 V or more. | B |
Turn the power switch off.
A
B
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read the freeze frame data of DTC P30004B.
Although freeze frame data is recorded before and after a DTC is stored, for this step it is only necessary to read the freeze frame data recorded at "0s" (when the DTC was stored).
| Result | Proceed to |
|---|---|
| Other than below | A |
| The value of any of "Hybrid Battery Temperature 1 to 3" is 80°C (176°F) or more. | B |
Turn the power switch off.
A
B
Connect the GTS to the DLC3.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Data List / Hybrid Battery Temperature 1 to 3.
| Tester Display |
|---|
| Hybrid Battery Temperature 1 |
| Hybrid Battery Temperature 2 |
| Hybrid Battery Temperature 3 |
According to the display on the GTS, read the Data List and check that the value of each "Hybrid Battery Temperature 1 to 3" is 40°C (104°F) or less.
If the value of any of "Hybrid Battery Temperature 1 to 3" is more than 40°C (104°F), turn the power switch off and wait until the values to decrease to 40°C (104°F) or less before continuing this procedure.
Enter the following menus: Powertrain / Hybrid Control / Data List / Hybrid Battery Block Voltage.
| Tester Display |
|---|
| Hybrid Battery Block 1 Voltage |
| Hybrid Battery Block 2 Voltage |
| Hybrid Battery Block 8 Voltage |
| Hybrid Battery Block 9 Voltage |
| Hybrid Battery Block 10 Voltage |
According to the display on the GTS, read the Data List and check the value of each "Hybrid Battery Block 1, 2, 8, 9 and 10 Voltage" with the power switch on (IG).
| *a | Hybrid Battery Block 1 Voltage | *b | Hybrid Battery Block 2 Voltage |
| *c | Hybrid Battery Block 3 Voltage | *d | Hybrid Battery Block 4 Voltage |
| *e | Hybrid Battery Block 5 Voltage | *f | Hybrid Battery Block 6 Voltage |
| *g | Hybrid Battery Block 7 Voltage | *h | Hybrid Battery Block 8 Voltage |
| *i | Hybrid Battery Block 9 Voltage | *j | Hybrid Battery Block 10 Voltage |
| Result | Proceed to |
|---|---|
| Other than below | A |
| The difference between the lowest and highest Hybrid Battery Block Voltage is 0.3 V or more. | B |
Turn the power switch off.
A
B
Connect the GTS to the DLC3.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Data List / Hybrid Battery Temperature 1 to 3.
| Tester Display |
|---|
| Hybrid Battery Temperature 1 |
| Hybrid Battery Temperature 2 |
| Hybrid Battery Temperature 3 |
According to the display on the GTS, read the Data List and check that the value of each "Hybrid Battery Temperature 1 to 3" is 40°C (104°F) or less.
If the value of any of "Hybrid Battery Temperature 1 to 3" is more than 40°C (104°F), turn the power switch off and wait until the values to decrease to 40°C (104°F) or less before continuing this procedure.
Enter the following menus: Powertrain / Hybrid Control / Data List / Hybrid Battery Block Voltage.
| Tester Display |
|---|
| Hybrid Battery Block 3 Voltage |
| Hybrid Battery Block 4 Voltage |
| Hybrid Battery Block 5 Voltage |
| Hybrid Battery Block 6 Voltage |
| Hybrid Battery Block 7 Voltage |
According to the display on the GTS, read the Data List and check the value of each "Hybrid Battery Block 3 to 7 Voltage" with the power switch on (IG).
| *a | Hybrid Battery Block 1 Voltage | *b | Hybrid Battery Block 2 Voltage |
| *c | Hybrid Battery Block 3 Voltage | *d | Hybrid Battery Block 4 Voltage |
| *e | Hybrid Battery Block 5 Voltage | *f | Hybrid Battery Block 6 Voltage |
| *g | Hybrid Battery Block 7 Voltage | *h | Hybrid Battery Block 8 Voltage |
| *i | Hybrid Battery Block 9 Voltage | *j | Hybrid Battery Block 10 Voltage |
| Result | Proceed to |
|---|---|
| Other than below | A |
| The difference between the lowest and highest Hybrid Battery Block Voltage is 0.3 V or more. | B |
Turn the power switch off.
A
B
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>BATTERY VOLTAGE SENSOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID VEHICLE CONTROL ECU>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT