The battery voltage sensor detects the HV battery conditions (voltage, current and temperature) and the battery cooling fan frequency, and sends the detected signals to the hybrid vehicle control ECU via serial communication. (The hybrid vehicle control ECU does not send signals to the battery voltage sensor.)
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| U029A87 | Lost Communication with Hybrid/EV Battery Sensor Module Missing Message | Serial communication error between the hybrid vehicle control ECU and battery voltage sensor: The hybrid vehicle control ECU cannot receive signals from the battery voltage sensor correctly.
(1 trip detection logic) |
·
Hybrid vehicle control ECU ·
Battery voltage sensor ·
Wire harness or connector |
Comes on | Master Warning: Comes on |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>UTILITY
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
With power switch on (IG) and wait for 2 minutes or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for DTC P0AFC00.
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>P0AFC00
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only U029A87 is output | A |
| DTCs other than U029A87 are also output | B |
Turn the power switch off.
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery protector.
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HV BATTERY>REMOVAL
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected
(Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M41-1 (IGCT) - M41-5 (GND) | Power switch on (IG) | 11 to 14 V |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
As there might be an intermittent malfunction in the battery voltage sensor power source circuit, inspect the following even if the measured voltage is as specified:
Installation condition of fuse(s) (before removing fuse(s)) (IGCT circuit)
Fuse condition (before and after removing fuse(s)) (IGCT circuit)
Connection condition of connectors (IGCT circuit)
Wire harness condition (IGCT circuit)
Wire harness condition (GND circuit)
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery protector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the hybrid vehicle control ECU connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Check that each connector between the hybrid vehicle control ECU and battery voltage sensor is not loose or disconnected.
Remove the No. 1 hybrid battery protector.
Disconnect the battery voltage sensor connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Check the terminals of the connector for deformation and corrosion.
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Rear view of wire harness connector
(to Battery Voltage Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F160-41 (BTH+) - M41-2 (BTH+) | Power switch off | Below 1 Ω |
| F160-42 (BTH-) - M41-3 (BTH-) | Power switch off | Below 1 Ω |
| M41-2 (BTH+) - Other terminals and body ground | Power switch off | 10 kΩ or higher |
| M41-3 (BTH-) - Other terminals and body ground | Power switch off | 10 kΩ or higher |
Make sure that each connector between the battery voltage sensor and hybrid vehicle control ECU is not loose or disconnected and its terminals are not deformed or corroded.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F160-41 (BTH+) - Body ground | Power switch on (IG) | Below 1 V |
| F160-42 (BTH-) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the battery voltage sensor connector.
Install the No. 1 hybrid battery protector.
Reconnect the hybrid vehicle control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery protector.
Disconnect the battery voltage sensor connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Rear view of wire harness connector
(to Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M41-2 (BTH+) - M41-5 (GND) | Power switch on (IG) | 2.3 to 2.7 V |
| M41-3 (BTH-) - M41-5 (GND) | Power switch on (IG) | 2.3 to 2.7 V |
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M41-2 (BTH+) - M41-3 (BTH-) | Power switch off | 4.4 to 5.4 kΩ |
The resistance will be 2.0 kΩ or less if there is an internal short in the hybrid vehicle control ECU.
Reconnect the battery voltage sensor connector.
Install the No. 1 hybrid battery protector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID VEHICLE CONTROL ECU>REMOVAL