G921E
1.INSTALL INVERTER PROTECTOR
| *a | Pin |
Install the inverter protector to the inverter with converter assembly with the bolt.
Make sure to align the hole of the inverter protector with the pin.
2.INSTALL WIRE HARNESS CLAMP BRACKET
Install the wire harness clamp bracket to the inverter with converter assembly with the 2 bolts.
Install the wire harness clamp bracket to the inverter with converter assembly with the bolt.
Install the wire harness clamp bracket to the inverter with converter assembly with the 2 bolts.
33829E
3.INSTALL TRANSMISSION CONTROL CABLE SUPPORT
Install the transmission control cable support to the inverter with converter assembly with the bolt.
G9215
4.INSTALL NO. 2 INVERTER BRACKET
| *a | Bottom of Inverter with Converter Assembly |
| *b | Support |
Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.
| *a | Wooden Block |
Set the inverter with converter assembly on wooden blocks.
Temporarily install the No. 2 inverter bracket to the inverter with converter assembly with the 2 bolts.
Fully tighten the 2 bolts in the order shown in the illustration.
G9214
5.INSTALL NO. 1 INVERTER BRACKET
| *a | Wooden Block |
Temporarily install the No. 1 inverter bracket to the inverter with converter assembly with the 2 bolts.
Fully tighten the 2 bolts in the order shown in the illustration.
G9200
6.INSTALL INVERTER WITH CONVERTER ASSEMBLY
Be sure to wear insulated gloves.
Temporarily install the inverter with converter assembly with the 5 bolts and 2 nuts.
When installing the inverter with converter assembly, be careful not to damage the parts around it.
To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
| *a | Correct |
| *b | Incorrect |
Make sure that the inverter with converter assembly is positioned so that the stud bolts are in contact with the base of the U-shaped portions of the No. 1 inverter bracket.
If the bolts and nuts are not tightened appropriately, the inverter with converter assembly may make an abnormal noise.
Fully tighten the bolt (A).
Fully tighten the 3 bolts (B).
Fully tighten the bolt (C).
Fully tighten the 2 nuts (D).
G1148
7.CONNECT MOTOR CABLE
Be sure to wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Temporarily connect the motor cable to the inverter with converter assembly with the 4 bolts.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during connection.
| *a | Waterproof Seal |
Fully tighten the bolt (A).
Fully tighten the 3 bolts in the order shown in the illustration to connect the motor cable to the inverter with converter assembly.
Temporarily install the 6 bolts.
To prevent the threads from being damaged, temporarily tighten the 6 bolts by hand.
Do not damage the terminals, connector housing or inverter with converter assembly during connection.
Using an insulated tool, fully tighten the 6 bolts.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during connection.
Be sure to use a torque wrench to tighten the bolts.
G9221
8.INSTALL INVERTER COVER
Wear insulated gloves.
Install the inverter cover to the inverter with converter assembly with the 2 bolts.
Visually confirm that the inverter cover waterproof seal is securely installed before installing the inverter cover.
Do not touch the waterproof seal of the inverter cover.
Make sure that the interlock is fully engaged.
Do not damage the terminals, interlock connector or inverter with converter assembly during installation.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
| *1 | Inverter Cover |
| *a | Screw |
Do not remove or excessively tighten the screw of the inverter cover.
Although the inverter cover may feel loose, this is not due to a malfunction.
| *a | No Gap |
Push in the inverter cover until it contacts the inverter with converter assembly.
17771A
9.INSTALL AIR CLEANER BRACKET
Install the air cleaner bracket with the bolt.
Engage the clamp.
G922AA
10.CONNECT INLET NO. 1 INVERTER COOLING HOSE
| *a | Alignment Mark (Yellow) |
| *b | Alignment Mark of Pipe |
| *c | 2 to 6 mm (0.0787 to 0.236 in.) |
| *d | Up |
| *e | LH Side |
Connect the inlet No. 1 inverter cooling hose to the inverter with converter assembly and slide the clip to secure it.
To prevent foreign matter from entering the inverter with converter assembly and inverter cooling system, do not remove the pieces of cloth from the pipe and disconnected hose until installation.
Make sure to align the alignment mark of the hose with the alignment mark of the pipe of the inverter with converter assembly.
Make sure that the clip is positioned as shown in the illustration.
G922C
11.CONNECT OUTLET NO. 1 INVERTER COOLING HOSE
| *a | Alignment Mark (Yellow) |
| *b | Rib |
| *c | 2 to 6 mm (0.0787 to 0.236 in.) |
Connect the outlet No. 1 inverter cooling hose assembly to the inverter with converter assembly and slide the clip to secure it.
To prevent foreign matter from entering the inverter with converter assembly and inverter cooling system, do not remove the pieces of cloth from the pipe and disconnected hose until installation.
Make sure to align the alignment mark of the hose with the rib of the inverter with converter assembly.
82121
12.CONNECT ENGINE WIRE
Be sure to wear insulated gloves.
Engage the clamp and connect the engine wire to the inverter with converter assembly.
Install the 2 nuts.
Engage the 2 clamps.
Temporarily install the nut.
To prevent the threads from being damaged, temporarily tighten the nut by hand.
Fully tighten the nut.
Engage the 2 claws to close the engine wire terminal cover.
Connect the engine wire to the inverter with converter assembly with the bolt.
Connect the engine wire to the inverter with converter assembly with the bolt.
Engage the 2 claws to connect the engine wire to the No. 1 engine room relay block.
Connect the 3 No. 1 engine room relay block connectors.
Install the No. 1 relay block cover to the No. 1 engine room relay block.
13.INSTALL WIRE HARNESS CLAMP BRACKET
Be sure to wear insulated gloves.
Install the wire harness clamp bracket to the inverter with converter assembly with the nut.
821H2
14.CONNECT HV AIR CONDITIONING WIRE
Be sure to wear insulated gloves.
Engage the clamp.
Connect the HV air conditioning wire to the inverter with converter assembly and install the 2 bolts.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connector.
821H1
15.CONNECT HV FLOOR UNDER WIRE
Be sure to wear insulated gloves.
Engage the 2 clamps.
Connect the HV floor under wire to the inverter with converter assembly and install the 2 bolts.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connector.
82121
16.CONNECT ENGINE WIRE
Be sure to wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Connect the 2 inverter with converter assembly connectors move the lock lever as shown in the illustration.
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connectors.
Do not touch the waterproof seal or terminals of the connectors.
33820B
17.CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY
Engage the 2 clamps.
Install the bolt to connect the transmission control cable assembly.
17701
18.INSTALL AIR CLEANER CASE SUB-ASSEMBLY
Install the air cleaner case sub-assembly with the 3 bolts.
17801
19.INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
20.INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE
89661
21.INSTALL ECM
G3834
22.INSTALL SERVICE PLUG GRIP
23.ADD COOLANT (for Inverter)
24.INSPECT FOR COOLANT LEAK (for Inverter)
51444A
25.INSTALL REAR ENGINE UNDER COVER LH
26.PERFORM INITIALIZATION