Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › from 2019.09
RM32K0E _58 Vehicle Interior _061609 HEATING / AIR CONDITIONING _0300711 AIR CONDITIONING SYSTEM U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  TERMINALS OF ECU  


AIR CONDITIONING AMPLIFIER ASSEMBLY


E334599C03
2.51,0.271 2.906,0.542 0.396,0.271 3.885,0.271 4.281,0.542 0.396,0.271 5.094,0.396 5.479,0.615 0.385,0.219 5.094,0.104 5.479,0.323 0.385,0.219 2.604,0.323 3.063,0.521 0.458,0.198 10 false F71 3.969,0.323 4.427,0.521 0.458,0.198 10 false F73 5.24,0.417 5.698,0.615 0.458,0.198 10 false f5 5.24,0.135 5.698,0.333 0.458,0.198 10 false f1 5.531,0.406 5.99,0.604 0.458,0.198 12 false *B 5.531,0.115 5.99,0.313 0.458,0.198 12 false *A
*A for TMMT Made HFQ-1234yf Type or TMC Made *B for TMMT Made HFC-134a (R134a) Type


HINT:

Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.


Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Specified Condition
F71-1 (SG-1) - Body ground LG - Body ground Ground for cooler (room temp. sensor) thermistor Always Below 1 V
F71-2 (SG-2) - Body ground G - Body ground Ground for thermistor assembly, air conditioner pressure sensor Always Below 1 V
F71-6 (S5-3) - F71-2 (SG-2) GR - G Power supply for air conditioner pressure sensor Power switch on (IG) 4.75 to 5.25 V
Power switch off Below 1 V
F71-10 (PTC2) - F73-4 (GND)*1 V - W-B Quick heater assembly operation signal
·

Power switch on (READY)

·

ECO mode: Off

·

Temperature setting: MAX HOT

·

Ambient temperature: 16°C (61°F) or lower

·

Engine coolant temperature: 70°C (158°F) or lower

·

Light control switch off

·

Blower switch: On


Below 1 V
·

Power switch on (READY)

·

ECO mode: Off

·

Temperature setting: MAX HOT

·

Ambient temperature: 16°C (61°F) or lower

·

Engine coolant temperature: 70°C (158°F) or lower

·

Light control switch off

·

Blower switch: Off


11 to 15.5 V
F71-11 (PTC3) - F73-4 (GND)*1 BR - W-B Quick heater assembly operation signal
·

Power switch on (READY)

·

ECO mode: Off

·

Temperature setting: MAX HOT

·

Ambient temperature: -7°C (19°F) or lower

·

Engine coolant temperature: 65°C (149°F) or lower

·

Light control switch off

·

Blower switch: On


Below 1 V
·

Power switch on (READY)

·

ECO mode: Off

·

Temperature setting: MAX HOT

·

Ambient temperature: -7°C (19°F) or lower

·

Engine coolant temperature: 65°C (149°F) or lower

·

Light control switch off

·

Blower switch: Off


11 to 15.5 V
F71-13 (TAM) - F71-2 (SG-2) W - G Thermistor assembly signal
·

Power switch on (IG)

·

Ambient temperature: 25°C (77°F)


1.35 to 1.75 V
·

Power switch on (IG)

·

Ambient temperature: 40°C (104°F)


0.9 to 1.2 V
F71-14 (TR) - F71-1 (SG-1) B - LG Cooler (room temp. sensor) thermistor signal
·

Power switch on (IG)

·

Cabin temperature: 25°C (77°F)


1.8 to 2.2 V
·

Power switch on (IG)

·

Cabin temperature: 40°C (104°F)


1.2 to 1.6 V
F71-24 (PRE) - F71-2 (SG-2) V - G Air conditioner pressure sensor signal (for HFC-134a(R134a))
·

Power switch on (READY)

·

Air conditioning system operating

·

Refrigerant pressure: Normal pressure (less than 3.025 MPa (30.8 kgf/cm2, 439 psi) and more than 0.176 MPa (1.8 kgf/cm2, 26 psi))


0.74 to 4.61 V
Air conditioner pressure sensor signal (for HFO-1234yf(R1234yf))
·

Power switch on (READY)

·

Air conditioning system operating

·

Refrigerant pressure: Normal pressure (less than 2.812 MPa (28.7 kgf/cm2, 408 psi) and more than 0.196 MPa (2.0 kgf/cm2, 28 psi))


0.74 to 4.61 V
F73-1 (B) - F73-4 (GND) V - W-B Power source (Back-up) Power switch off 11 to 14 V
F73-2 (IG+) - F73-4 (GND) B - W-B Power source (IG) Power switch on (IG) 11 to 14 V
Power switch off Below 1 V
F73-4 (GND) - Body ground W-B - Body ground Ground for main power supply Always Below 1 V
F73-6 (BLW) - F73-4 (GND) Y - W-B Blower motor speed control signal
·

Power switch on (IG)

·

Blower switch: LO


Pulse generation
(See waveform 1)
F73-11 (CANH) - F73-12 (CANL) P - SB CAN communication signal CAN communication is performed Pulse generation
F73-14 (LIN1) - F73-4 (GND) L - W-B*2
BE - W-B*3
LIN communication signal (Air conditioning control assembly) Power switch on (IG) Pulse generation
(See waveform 2)
F73-18 (PTC1) - F73-4 (GND)*1 L - W-B Quick heater assembly operation signal
·

Power switch on (READY)

·

ECO mode: Off

·

Temperature setting: MAX HOT

·

Ambient temperature: 25°C (77°F) or lower

·

Engine coolant temperature: 75°C (167°F) or lower

·

Light control switch off

·

Blower switch: On


Below 1 V
·

Power switch on (READY)

·

ECO mode: Off

·

Temperature setting: MAX HOT

·

Ambient temperature: 25°C (77°F) or lower

·

Engine coolant temperature: 75°C (167°F) or lower

·

Light control switch off

·

Blower switch: Off


11 to 15.5 V
F73-7 (NANO) - F73-4 (GND)*4 R - W-B Ion generator sub-assembly operation signal
·

Power switch on (IG)

·

Blower switch: LO

·

"nanoe" switch: On


Below 1 V
·

Power switch on (IG)

·

Blower switch: LO

·

"nanoe" switch: On


11 to 14 V
F73-26 (NAIN) - F73-4 (GND)*4 W - W-B Ion generator sub-assembly operation condition signal
·

Power switch on (IG)

·

Blower switch: LO

·

"nanoe" switch: On


Below 1 V
·

Power switch on (IG)

·

Blower switch: LO

·

"nanoe" switch: On


4.75 to 5.25 V
f1-2 (BUSG) - Body ground*5 B - Body ground Ground for BUS IC Always Below 1 V
f1-3 (BUS) - f1-2 (BUSG)*5 L - B BUS IC control signal Power switch on (IG) Pulse generation
(See waveform 3)
f1-4 (BUSB) - f1-2 (BUSG)*5 R - B Power supply for BUS IC Power switch off 11 to 14 V
f1-5 (SG-3) - Body ground*5 GR - Body ground Ground for No. 1 cooler thermistor (evaporator temperature sensor) Always Below 1 V
f1-6 (TE) - f1-5 (SG-3)*5 GR - GR No. 1 cooler thermistor (evaporator temperature sensor)
·

Power switch on (IG)

·

Evaporator temperature: 0°C (32°F)


1.7 to 2.1 V
·

Power switch on (IG)

·

Evaporator temperature: 15°C (59°F)


0.9 to 1.3 V
f5-2 (BUSG) - Body ground*6 B - Body ground Ground for BUS IC Always Below 1 V
f5-3 (BUS) - f5-2 (BUSG)*6 L - B BUS IC control signal Power switch on (IG) Pulse generation
(See waveform 3)
f5-4 (BUSB) - f5-2 (BUSG)*6 R - B Power supply for BUS IC Power switch off 11 to 14 V
f5-5 (SG-3) - Body ground*6 GR - Body ground Ground for No. 1 cooler thermistor (evaporator temperature sensor) Always Below 1 V
f5-6 (TE) - f5-5 (SG-3)*6 GR - GR No. 1 cooler thermistor (evaporator temperature sensor)
·

Power switch on (IG)

·

Evaporator temperature: 0°C (32°F)


1.7 to 2.1 V
·

Power switch on (IG)

·

Evaporator temperature: 15°C (59°F)


0.9 to 1.3 V

*1: w/ PTC Heater

*2: for LHD

*3: for RHD

*4: w/ Ion Generator

*5: for TMMT Made HFQ-1234yf (R1234fy) Type or TMC Made

*6: for TMMT Made HFC-134a (R134a) Type


a.
E338778N04
2.823,1.24 3.281,1.438 0.458,0.198 10 false GND

Waveform 1:

Item Content
Terminal No. F73-6 (BLW) - F73-4 (GND)
Tool Setting 2 V/DIV., 1 ms./DIV.
Vehicle Condition
·

Power switch on (IG)

·

Blower switch: LO




b.
E334619N07
0.313,1.563 0.771,1.76 0.458,0.198 10 false GND

Waveform 2:

Item Content
Terminal No. F73-14 (LIN1) - F73-4 (GND)
Tool Setting 2 V/DIV., 20 ms./DIV.
Vehicle Condition Power switch on (IG)


c.
E202803N15
0.333,1.469 0.75,1.646 0.417,0.177 10 GND

Waveform 3:

Item Content
Terminal No. f5-3 (BUS) - f5-2 (BUSG)
Tool Setting 2 V/DIV., 2 ms./DIV.
Vehicle Condition Power switch on (IG)



AIR CONDITIONING CONTROL ASSEMBLY


E352244N02
3.26,0.25 3.76,0.5 0.5,0.25 3.396,0.271 4.469,0.469 1.073,0.198 10 false F61

HINT:

Check from the rear of the connector while it is connected to the air conditioning control assembly.


Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Specified Condition
F61-16 (GND) - Body ground W-B - Body ground Ground for air conditioning control assembly Always Below 1 V
F61-2 (LIN1) - Body ground L - Body ground LIN communication signal Power switch on (IG) Pulse generation
(See waveform 1)
F61-10 (IG+) - F61-16 (GND) BE - W-B Power source (IG) Power switch off Below 1 V
Power switch on (IG) 11 to 14 V

a.
E334619N07
0.313,1.563 0.771,1.76 0.458,0.198 10 false GND

Waveform 1:

Item Content
Terminal No. F61-2 (LIN1) - Body ground
Tool Setting 2 V/DIV., 20 ms./DIV.
Vehicle Condition Power switch on (IG)