Home › Drivetrain › K114 (MULTIDRIVE / CVT) › CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM › 2016.10–2020.08
RM32H0E _52 Drivetrain _059616 K114 MULTIDRIVE / CVT _0292534 CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM C

K114 MULTIDRIVE / CVT  CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM  P2822  Pressure Control Solenoid "J" Electrical (Shift Solenoid Valve SLP)  


DESCRIPTION

According to current control by the ECM, the shift solenoid valve SLP controls primary pulley pressure in accordance with the requested gear ratio to perform gear ratio changes.

C300481C04
4.677,1.552 4.125,0.49 4.125,0.49 3.906,0.49 true 4.5,1.75 4.125,2.344 4.125,2.344 3.906,2.344 true 5.438,1.844 5.125,2.344 5.125,2.344 4.906,2.344 true 5.125,2.323 5.427,1.292 true 0.792,1.229 1.042,1.417 0.25,0.188 10 false *a 1.583,1.99 2.01,2.188 0.427,0.198 10 false *b 3.729,0.427 4.042,0.625 0.313,0.198 10 false *1 3.729,2.281 4.042,2.479 0.313,0.198 10 false *2 4.708,2.281 5.021,2.479 0.313,0.198 10 false *3
*1 Spool Valve *2 Sleeve
*3 Solenoid Coil - -
*a Hydraulic Pressure *b Current Flow to Solenoid


DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2822 Pressure Control Solenoid "J" Electrical (Shift Solenoid Valve SLP) While the vehicle is driven, an open or a short is detected in the shift solenoid valve SLP circuit for 1 second or more (1 trip detection logic).
·

Wire harness or connector

·

Continuously variable transaxle assembly (Shift solenoid valve SLP)

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SLP circuit. If there is an open or short in the shift solenoid valve SLP circuit, the ECM detects the malfunction, illuminates the MIL and stores this DTC.

WIRING DIAGRAM

C328132E32
0.26,1.604 2.052,1.833 1.792,0.229 10 false Shift Solenoid Valve SLP 4.323,1.01 4.938,1.208 0.615,0.198 10 false SLP+ 4.771,1.01 4.927,1.208 0.156,0.198 10 false 3 5.156,1.01 5.469,1.208 0.313,0.198 10 false 39 4.323,1.979 4.938,2.177 0.615,0.198 10 false SLP- 5.427,1.01 6.042,1.208 0.615,0.198 10 false SLP+ 5.427,1.979 6.042,2.177 0.615,0.198 10 false SLP- 4.76,1.979 5.073,2.177 0.313,0.198 10 false 9 5.156,1.979 5.469,2.177 0.313,0.198 10 false 38 2.729,2.448 3.188,2.646 0.458,0.198 10 false C40 2.729,2.604 4.01,2.865 1.281,0.26 10 false Transmission Wire 1.115,3.073 3.906,3.313 2.792,0.24 10 false Continuously Variable Transaxle Assembly 5.875,3.031 6.49,3.229 0.615,0.198 10 false C63 5.875,3.188 6.375,3.406 0.5,0.219 10 false ECM 6,0.74 6.615,0.938 0.615,0.198 10 false 12 V

CAUTION / NOTICE / HINT

NOTICE:
·

Perform initialization after replacing any parts related to the continuously variable transaxle system.

Click hereDrivetrain>K114 (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>INITIALIZATION

·

Check that no DTCs are stored after performing initialization.

Click hereDrivetrain>K114 (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>DTC CHECK / CLEAR



HINT:

After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.



PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLP)
a.
C298188C11
2.323,0.313 1.948,0.927 true 2.385,1.75 1.948,1.281 true 2.406,0.25 2.865,0.448 0.458,0.198 10 false SLP+ 2.479,1.729 2.938,1.927 0.458,0.198 10 false SLP- 0.104,0.104 0.563,0.302 0.458,0.198 10 false *a
*a Component without harness connected
(Transmission Wire)


Disconnect the C40 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 (SLP+) - 9 (SLP-) 20°C (68°F) 5.0 to 5.6 Ω
3 (SLP+) - Body ground and other terminals Always 10 kΩ or higher
9 (SLP-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

4.REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
C364977C13
1.333,0.094 1.75,0.333 0.417,0.24 0.885,1 0.521,1.792 true 0.958,1.01 1.49,1.792 true 1.438,0.135 1.896,0.333 0.458,0.198 10 false C63 0.083,0.094 0.396,0.292 0.313,0.198 10 false *a 0.344,1.833 1.115,2.021 0.771,0.188 10 false 38 (SLP-) 1.302,1.844 2.094,2.104 0.792,0.26 10 false 39 (SLP+)
*a Front view of wire harness connector
(to ECM)


Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C63-39 (SLP+) - C63-38 (SLP-) 20°C (68°F) 5.0 to 5.6 Ω
C63-39 (SLP+) - Body ground and other terminals Always 10 kΩ or higher
C63-38 (SLP-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.REPLACE ECM

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)

3.REPLACE ECM

Result:
Proceed to
NEXT



NEXT

4.REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY

Result:
Proceed to
NEXT



NEXT