The thermistor assembly is installed in front of the cooler condenser assembly to detect the ambient temperature, which is used to control the air conditioning system. This sensor is connected to the combination meter assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the combination meter assembly. The resistance of the thermistor assembly changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The combination meter assembly applies a voltage (5 V) to the thermistor assembly and reads voltage changes due to changes in the resistance of the thermistor assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1412 | Ambient Temperature Sensor Circuit | When the air conditioning amplifier assembly receives out-of-range outside temperature sensor data from the combination meter assembly. | ·
Thermistor assembly ·
Harness or connector between thermistor assembly and combination meter assembly ·
Air conditioning amplifier assembly ·
Combination meter assembly ·
CAN communication system |
Memorized
(4 seconds or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
If the ambient temperature is approximately -80.0°C (-112°F) or lower, DTC B1412 may be output even though the system is normal.
When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.
Check if CAN communication DTCs are output.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM
| Result | Proceed to |
|---|---|
| CAN communication DTCs are not output. | A |
| CAN communication DTCs are output. | B |
A
B
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
Connect the GTS to the DLC3.
Turn the ignition switch ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temperature | Outside temperature | Min.: -40°C (-40°F)
Max.: 87.5°C (189.5°F) |
Almost the same as actual outside temperature | The temperature displayed on the multiinformation display is -40 to 50°C (-40 to 122 °F) |
| Tester Display |
|---|
| Ambient Temperature |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
A
B
C
Remove the thermistor assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL
Inspect the thermistor assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A3 thermistor assembly connector.
Disconnect the F4 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F4-34 (TEMP) - A3-2 | Always | Below 1 Ω |
| F4-35 (TX1+) - A3-1 | Always | Below 1 Ω |
| F4-34 (TEMP) or A3-2 - Body ground | Always | 10 kΩ or higher |
| F4-35 (TX1+) or A3-1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Clear the DTCs.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTCs are output | B |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B