When the theft deterrent system is switched from the armed state to the alarm sounding state, the main body ECU (multiplex network body ECU) transmits a signal to cause the security horn assembly to sound at intervals of 0.4 seconds.
Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.
Inspect the fuses for circuits related to this system before performing the following procedure.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Security Horn | Security horn Assembly | OFF/ON | - |
| Tester Display |
|---|
| Security Horn |
The security horn assembly sounds and stops correctly when operated through the GTS.
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG | C |
A
B
C
Remove the security horn assembly.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SECURITY HORN ASSEMBLY>REMOVAL
Inspect the security horn assembly.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SECURITY HORN ASSEMBLY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the S-HORN relay from the No. 4 relay block assembly.
Inspect the S-HORN relay.
Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>RELAY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the main body ECU (multiplex network body ECU).
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
Disconnect the 3A instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-20 - MB-29 (SH) | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
A
B
C
Remove the S-HORN relay from the No. 4 relay block assembly.
| *1 | No. 4 Relay Block Assembly |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| No. 4 relay block assembly S-HORN relay terminal 1 - Body ground | Always | 11 to 14 V |
| No. 4 relay block assembly S-HORN relay terminal 5 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the S-HORN relay from the No. 4 relay block assembly.
Disconnect the A15 security horn assembly connector.
| *1 | No. 4 Relay Block Assembly |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| No. 4 relay block assembly S-HORN relay terminal 3 - A15-1 | Always | Below 1 Ω |
| No. 4 relay block assembly S-HORN relay terminal 3 or A15-1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the S-HORN relay from the No. 4 relay block assembly.
Disconnect the 3A instrument panel junction block assembly connector.
| *1 | No. 4 Relay Block Assembly |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| No. 4 relay block assembly S-HORN relay terminal 2 - 3A-20 | Always | Below 1 Ω |
| No. 4 relay block assembly S-HORN relay terminal 2 or 3A-20 - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG | C |
A
B
C